Martin
®
ERA 150 Wash User Guide
43
CALIBRATION
(continued)
CTC
0 - 255
Adjust 6000 K
center point
CTC Tint
0 - 255
Adjust green/
magenta tint
RAW CTC
0 - 255
Adjust 6000 K
center point
RAW CTC Tint
0 - 255
Adjust green/
magenta tint
ZOOM
-128 - 127
Calibrate zoom
LOAD
DEFAULTS
LOAD
Load the factory
default calibration
settings
SAVE
Save current
custom calibration
settings.
See note below!
SAVE SETTING SAVE
Replace factory
default calibration
settings with
custom values
or zero values.
See note below!
CLEAR ALL
VALUES
RESTORE
Reset all calibration
values to zero.
See note below!
USB
UPDATING
FILES
ERA150
1.1.0
ERA150
X.X.X
Firmware versions
available when
USB memory
device is connected
Important!
•
LOAD DEFAULTS
→
SAVE stores any custom calibration values that
you have created in the CALIBRATION menu. The fixture will keep
using these values even when the fixture power is cycled off and on.
•
LOAD DEFAULTS
→
LOAD loads the original factory default calibration
values (unless these have been overwritten or erased
–
see below)
•
CLEAR ALL VALUES → RESTORE erases all calibration settings –
both custom settings and the original factory settings.
Important! If you
use this command you will need to fully recalibrate the fixture.