VC-Grid Safety and Installation Guide
Testing, rebooting and returning to defaults
The tables below list the functions of the control button on each VC-Grid module.
Test patterns are stored in onboard memory. This lets you test the LEDs without an external controller, but
test patterns can also be called up on P3 system controllers and the P3 PowerPort 1500™.
VC-Grid CW, MW and WW
Button action
Function
Short press
The first press displays status as shown in Table 2 for a few seconds.
The next presses display the following test patterns on the LEDs (one
short press scrolls to next pattern):
- Calibrated white
- Full red
- Full green
- Full blue
- Vertical scrolling gradient
Press and hold until
all LEDs light blue
Reboot the VC-Grid.
Press and hold until
all LEDs light white
Return the VC-Grid to its default factory firmware.
Table 4: RGB control button functions
Button action
Function
Short press
The first press displays status as shown in Table 3 for a few seconds.
The next presses display the following test patterns on the LEDs (one
short press scrolls to next pattern):
- Calibrated white 100%
- White 33%
- White 33%
- White 33%
- Scrolling gradient
Press and hold until
LEDs 1, and 3 light
Reboot the VC-Grid.
Press and hold until
LEDs 1, 2, 3 and 4
light
Return the VC-Grid to its default factory firmware.
Table 5: White models control button functions