Magnafire Series Coal Stoves
6
2.3 ASSEMBLY.
Slide the blower into the slotted bracket on the rear
of the stove. The blower will rest at the bottom of the
slot.
The shaker handle bolts onto the shaker block using
the bolts and lock washers provided.
The draft control is bolted through the hole in the
center of the ash door as shown below. The knob
should spin freely and open to a distance of about 1/4
inch from the door surface, while being able to close
against the face of the door.
The viewing glass is installed between the door and
the window frame. The glass gasket is installed only
on the sides of the glass panel. The top and bottom of
the glass are open to provide air-wash and secondary
air to the firebox. The glass frame is secured to the
door with four bolts.
The Mark II and Mark III also have a top trim piece
which bolts onto the top of the door.
be sure the frame bolts and trim bolts are secured.
2.4 GENERAL INFORMATION.
Installation Checklist:
a. Have your stove installed by a trained installer.
Preferably one who is certified by the National
Fireplace Institute or similar certification agency.
b. before starting Installation, check for proper
clearance to combustibles where the stove is going to
be located.
C. Never vent a solid fuel burning appliance into a
flue serving another appliance.
d. Have the chimney inspected and thoroughly
cleaned. Inspect that it is a Class “a” chimney either
masonry or factory built. If it is a manufactured chimney,
ensure that it is installed as per the manufacturers
requirements. be sure that the chimney is tall enough.
Solid fuel chimneys fall under a general rule, 16 ft.
minimum height, 2 ft. taller than anything within 10 ft.,
and 3 ft. above where it passes through the roof line.
The chimney must be capable of a minimum .06 inches
of water column of draft when the stove is burning.
e. limit the amount of connector pipe. Position the
stove as close to the flue as possible. (8 ft. or less)
No more than two 90° elbow fittings should be used.
any horizontal connector pipe should have at least
1/4 in. of rise per foot in length. a barometric damper
may be installed to prevent excessive or erratic draft.
MANUAL DAMPERS OR “HEAT SAVERS” MUST
NEVER BE INSTALLED IN THE FLUE PIPE.
IMPROPER OPERATION COULD RESULT IN
DEATH.
Installation
Содержание Mark I
Страница 2: ......
Страница 21: ...Magnafire Series Coal Stoves 21 Service Maintenance Log Date Of Service Performed By Description Of Service...
Страница 22: ...Magnafire Series Coal Stoves 22 Service Maintenance Log Date Of Service Performed By Description Of Service...
Страница 23: ......
Страница 24: ...Proudly Printed On 100 Recycled Paper...