background image

JBL Professional

®

 Intellivox ADC Installation Manual

16

202011/ADCIM

MODEL V90 ONLY

Model V90 only: There are three options for mounting 
the Intellivox ADC Model V90: 

1. The first (and most often used) method is to use the
standard mounting brackets supplied with the unit.
Dimensions of the bracket are shown in fig.5.1.

The standard brackets allow mounting of the Intellivox 
ADC Model V90 on a straight wall or on a curved surface 
(e.g., a pillar) with a gap of 25 mm (1.0”) between the 
rear of the enclosure and the wall. 

The mounting procedure is given on page 13 under 
“Mounting Procedure”. 

2. A second method is to mount the Model V90 using
(optional) swivel brackets which allow the plane of the
column’s vertical radiating axis to be at an angle other
than 90 degrees to the wall. In this case two swivel
brackets are needed. The horizontal angle of the swivel
brackets can be secured by the hexagonal nut. The
swivel brackets are mounted to the rear of the enclosure
by the four M5 pan head screws instead of the standard
brackets. Two versions of swivel brackets are available,

permitting the Intellivox to be rotated through 45 or 90 
degrees either way respectively. Refer to page 17 for 
ordering information.

3. The third method is to mount the column within a
recess in the wall or dedicated mounting panel so
that the front of the unit is flush. This is a specialised
mounting situation which will be encountered only
rarely. Access to the rear of the unit will still be required
for the cables. Because of the proximity of the unit to
the walls, particular attention should be paid to the
avoidance of acoustic resonances (see page 11).

MODEL H90 ONLY

Model H90 only: Unlike the V90, considerable flexibility 
exists in the mounting possibilities of the H90. The H90 
is not specifically designed to be mounted on a vertical 
(or angled) wall. The method of mounting employed 
in a particular installation will be primarily dictated by 
the downwards angle at which the H90 needs to be 
mounted to achieve the coverage calculated during the 
DDA analysis. 

Custom mounting hardware may be required to achieve 
the correct mounting angle. Small mounting angles 
may be realised using the standard mounting brackets 
(supplied) in conjunction with suitable spacers. 

The standard mounting brackets supplied with the unit 
may be employed if the Model H90 is to be fixed “flat” 
onto a vertical wall. 

Note that the provided locking mechanism of the 
optional hinges and swivel brackets is not suitable for 
the standard (horizontal) mounting method.

fig.5.2 - 
Direction of rotation 
when using optional 
swivel brackets with  
the V90

Содержание JBL Intellivox ADC-V90

Страница 1: ...Installation Manual Intellivox ADC V90 ADC H90 models SKU IVX 576125 IVX 577125 IVX 577135 IVX 576126 IVX 577126 and IVX 577136 EN54 24...

Страница 2: ...ls Construction product description Loudspeaker for voice alarm systems for fire detection and fire alarm systems for buildings Product model type ADC V90 ADC H90 Document references Datasheet s 20201...

Страница 3: ...in accordance with the applicable harmonised technical specification as foreseen by the manufacturer Construction product Loudspeaker for voice alarm systems for fire detection and fire alarm systems...

Страница 4: ...ystem 1 7 Declaration of performance concerning a construction product covered by a harmonised standard Notified body details Name Scientific and Research Centre for Fire Protection named after J zef...

Страница 5: ...assed Section 4 4 Marking and data Passed Section 4 5 Rated noise power durability Passed Section 5 6 Enclosure protection Passed Section 5 18 Dry heat operational Passed Section 5 7 Dry heat enduranc...

Страница 6: ...performance of the product identified in points 1 and 2 is in conformity with the declared performance in point 9 This declaration of performance is issued under the sole responsibility of the manufa...

Страница 7: ...te names mentioned in this manual may be registered trademarks or copyrights of their respective companies They are used here for indicative purposes only The information contained in this manual has...

Страница 8: ...ion 11 Applicable models and variants 11 What s in the packaging 12 3 Installation Guide 13 Preparing for Installation 13 Intellivox ADC connections 13 Mechanical Installation 14 Model V90 only 14 Mod...

Страница 9: ...s radiators heat registers stoves or other apparatus including amplifiers that produce heat 9 Only use attachments accessories specified by the manufacturer 10 Use only with the cart stand tripod brac...

Страница 10: ...thermal fuse and ceramic terminal block EQ correction and high pass filter This manual covers Wiring and connection details Mechanical installation of the loudspeaker Please note that a full range of...

Страница 11: ...is document ADC Datasheet Box containing REF ITEM QTY USE A Mounting brackets 2 Speaker mounting B 30 mm hex headed screws with washers and wall plugs 4 Mounting bracket fixings wall C M5 x 12 mm pan...

Страница 12: ...acket positions are in the same plane This restriction does not apply to the Model H90 which is intended to be tilted downwards INTELLIVOX ADC CONNECTIONS The Intellivox ADC range loudspeakers are des...

Страница 13: ...cker see fig 3 The horizontal position is on the vertical centre line When calculating the positions for the mountings see below the distance from the acoustic centre to the top or bottom of the louds...

Страница 14: ...wnwards radiating angle of the unit is correct fig 4 2 Acoustic centre reference point for H90 Reference point for acoustical mounting position H90 fig 4 3 H90 further mounting information A C H90 B M...

Страница 15: ...mation 3 The third method is to mount the column within a recess in the wall or dedicated mounting panel so that the front of the unit is flush This is a specialised mounting situation which will be e...

Страница 16: ...s on one or both brackets if necessary 6 Attach the brackets to the rear of the loudspeaker using the M5 x 12 pan head screws and shakeproof washers supplied The 10 mm diameter holes allow screwdriver...

Страница 17: ...g location the wiring scheme as indicated in fig 8 2 can be used Note that the application dependent safety regulations should be consulted in order to determine the proper grounding scheme TAP SETTIN...

Страница 18: ...sition The frequency response of the high pass filter is indicated in fig 10 2 Model V90 respectively fig 10 4 Model H90 The filter response is slightly dependent on the tap setting the curves are val...

Страница 19: ...lot tones of other frequencies and or levels may be used if the fault monitoring system demands them the illumination of the LED is not essential for such a system to operate correctly SPEAKER PROTECT...

Страница 20: ...SKU Intellivox wall bracket set 2 pcs 25 mm RAL 9007 IVX 802227 Intellivox hinge bracket 90 RAL 9007 IVX 802005 Intellivox swivel bracket 90 RAL 9007 IVX 806668 Intellivox swivel bracket 45 RAL 9007 I...

Страница 21: ...JBL Professional 8500 Balboa Boulevard Northridge CA 91329 U S A Copyright 2020 JBL Professional www jblpro com...

Отзывы: