background image

5

Front Panel 

General Purpose Indicator LEDs

These 48 software-programmable LEDs 

can be assigned to a control port or can 

be driven by the Soundweb London Logic 

system. Each LED is a multi-color indicator 

capable of red, green, or yellow illumination 

and can be independently configured within 

London Architect. 

Power Supply LED

When lit, this LED provides indication that the BLU-GPX is being powered 

through the SECONDARY POWER input connection on the back panel. 

Network Link

This LED indicates the presence of Cat 5 Ethernet cables. If no cables are 

connected, the LED is unlit; the LED lights if a control cable is fitted.

Data Activity

This LED will flash to indicate that the device is communicating with another control 

device, either on the network or via the serial or control ports.

LCD Display

Top line Indicates device name and run state. Bottom 

line indicates Time, IP Address, Subnet Mask, Model 

number with firmware version. Also, the device’s MAC 

Address can be viewed by powering the device on 

whilst pressing and holding the LOCATE switch. This 

display can be configured to display custom text using 

the Logic Display object in London Architect.

Locate

Pressing the LOCATE switch on the front of the unit will illuminate the LOCATE switch 

on the rear and identify the device within London Architect. Similarly the switch will 

illuminate if the device is selected from within London Architect or from the LOCATE 

switch on the rear.

Contrast (Hold)

Pressing and holding the LOCATE switch will cycle the LCD through its contrast range.

www.audiovias.com

Содержание BSS Audio Soundweb London BLU-GPX

Страница 1: ...1 Soundweb TM London BLU GPX Installation Guide 5009104 B www audiovias com...

Страница 2: ...ed service personnel or equivalent If connected to 240V supply a suitable CSA UL certified power cord shall be used for this supply This Equipment is intended for rack mount use only Safety Instructio...

Страница 3: ...rge to designated collection facilities or to a retailer if you purchase a similar new one For Countries not mentioned above please contact your local authorities for a correct method of disposal By d...

Страница 4: ...sleeve STEWART TYPE 28A2029 0A0 near the network socket end This equipment must be earthed It should not be necessary to remove any protective earth or signal cable shield connections to prevent grou...

Страница 5: ...device is communicating with another control device either on the network or via the serial or control ports LCD Display Top line Indicates device name and run state Bottom line indicates Time IP Add...

Страница 6: ...closures for controlling binary parameters resistor ladders for controlling multi state parameters or potentiometers for controlling continuous parameters e g BLU 3 selector wallplate Part no Z BLU 3...

Страница 7: ...Open NO and Normally Closed NC terminals will open or close in response to HiQnet parameters They can be connected directly to resistance controlled electrical components circuits These RELAY OUTPUTS...

Страница 8: ...7kOhm log potentiometer Part no DM10018 connected between a control input and common will allow parameters to be controlled linearly 3 wire mode This mode allows the use of linear pots or faders for c...

Страница 9: ...oltage ground relay coil relay coil NC Normally Closed NO Normally Open C Common relay NC C NO Relay Outputs Logic Opto Outputs Relay Outputs LED supply voltage ground relay coil relay coil NC Normall...

Страница 10: ...AND DIMENSIONS Primary IEEE802 3af Power over Ethernet PoE Secondary 12 48VDC 19W external power supply Operating Temp Range 5 41 to 35 95 degrees C degrees F Dimensions HxWxD 1 75 45mm x 19 483mm x...

Страница 11: ...11 This page intentionally left blank www audiovias com...

Страница 12: ...12 BSS Audio 8760 South Sandy Parkway Sandy Utah 84070 801 566 8800 www bssaudio com Printed in the USA www audiovias com...

Отзывы: