Harman AXYS TUNNEL Intellivox ADC-V90 Скачать руководство пользователя страница 18

AXYS

®

 Intellivox ADC Installation Manual

18

201509/ADCIM

WIrING DETAIlS 

When the Intellivox ADC has been mounted in the 
correct position, it may be connected up. Connection 
is straightforward; having passed the cable through the 
gland, connect the speaker feed to the  ‘100 V’ and ‘0’ 
terminals of the ceramic connection block. 

Always ensure that the amplifier is powered 
down before wiring the loudspeaker. If the audio 
suddenly becomes live there is a strong risk of 

electric shock.

The third terminal, marked with an Earth (Ground) symbol, 
allows a separate earthing connection to be made to the 
loudspeaker. This provides a low impedance circuit to earth 
from the metalwork of the enclosure, as often required by 
safety regulations. If the loudspeaker enclosure is mounted 
on a support that offers a low impedance connection to the 
safety ground, the earth terminal of the ceramic connection 
block can be directly wired to the mounting support as 
indicated in fig.8.1. If a safety ground connection is 
not available in the vicinity of the mounting location, 
the wiring scheme as indicated in fig.8.2 can be used.  
Note that the application dependent safety regulations 
should be consulted in order to determine the proper 
grounding scheme.

TAP SETTING 

The internal 100 V/70 V transformer’s primary tapping 
should be set according to the power requirements of the 
installation. This figure will have been determined at the 
time of site analysis; see also the Maximum SPL figures in 
the specifications table on the data sheet. 

The tapping is set by means of an internal switch that is 
located behind the inspection plate as indicated in fig.9.2 
(Model V90) and fig.9.3 (Model H90). This switch has three 
positions, labelled 100 W, 50 W and 25 W. These figures 
relate to the speaker use on a 100 V line system, lower 
powers are available from a 70 V line system.

The table below summarises the output powers:   

Tap Switch  

setting

Max. output power (W) 

100 V line system 

70 V line system 

100 W

100

50

50 W

50

25

25 W

25

12.5

100 V

0

100 V-/70 V-line feed 

(2-core cable)

To safety earth

100 V-/70 V-line feed 

(3-core cable)

Brown

Blue

Green/yellow

100 V

0

Brown

Blue

Green/yellow

fig.8.2 - Wiring details B

fig.8.1 - Wiring details A

fig.9.1 - Tap settings

fig.9.2 - Switch locations (Model V90)

fig.9.3 -  Switch locations (Model H90)

Содержание AXYS TUNNEL Intellivox ADC-V90

Страница 1: ...Installation Manual Intellivox ADC V90 ADC H90 models Part Nos 576125 577125 577135 576126 577126 and 577136 EN54 24...

Страница 2: ...oudspeaker for voice alarm systems for fire detection and fire alarm systems for buildings Product model type ADC V90 ADC H90 Document references Datasheet s 201509 V90_2 3 ADC V90 datasheet 201509 H9...

Страница 3: ...with the applicable harmonised technical specification as foreseen by the manufacturer Construction product Loudspeaker for voice alarm systems for fire detection and fire alarm systems for buildings...

Страница 4: ...1 7 Declaration of performance concerning a construction product covered by a harmonised standard Notified body details Name Scientific and Research Centre for Fire Protection named after J zef Tulisz...

Страница 5: ...Section 4 4 Marking and data Passed Section 4 5 Rated noise power durability Passed Section 5 6 Enclosure protection Passed Section 5 18 Dry heat operational Passed Section 5 7 Dry heat endurance Pass...

Страница 6: ...in conformity with the declared performance in point 9 This declaration of performance is issued under the sole responsibility of the manufacturer identified in point 4 Signed for and on behalf of the...

Страница 7: ...mes mentioned in this manual may be registered trademarks or copyrights of their respective companies They are used here for indicative purposes only The information contained in this manual has been...

Страница 8: ...AXYS Intellivox ADC Installation Manual 8 201509 ADCIM This page has been left blank intentionally...

Страница 9: ...riants 11 What s in the packaging 12 3 Installation Guide 13 Preparing For Installation 13 Intellivox ADC Connections 13 Mechanical Installation 14 Acoustic Centre 14 Mounting Options 15 16 Mounting P...

Страница 10: ...ators heat registers stoves or other apparatus including amplifiers that produce heat 9 Only use attachments accessories specified by the manufacturer 10 Use only with the cart stand tripod bracket or...

Страница 11: ...mal fuse and ceramic terminal block EQ correction and high pass filter This manual covers Wiring and connection details Mechanical installation of the loudspeaker Please note that a full range of opti...

Страница 12: ...ument ADC Datasheet Box containing REF ITEM QTY USE A Mounting brackets 2 Speaker mounting B 30 mm hex headed screws with washers and wall plugs 4 Mounting bracket fixings wall C M5 x 12 mm pan head s...

Страница 13: ...plane This restriction does not apply to the Model H90 which is intended to be tilted downwards Intellivox ADC connections The Intellivox ADC range loudspeakers are designed to be connected to 100 V o...

Страница 14: ...see fig 3 The horizontal position is on the vertical centre line When calculating the positions for the mountings see below the distance from the acoustic centre to the top or bottom of the loudspeake...

Страница 15: ...ting angle of the unit is correct fig 4 2 Acoustic centre reference point for H90 Reference point for acoustical mounting position H90 fig 4 3 H90 further mounting information A C H90 B MOUNTING OPTIO...

Страница 16: ...he third method is to mount the column within a recess in the wall or dedicated mounting panel so that the f r o n t of the unit is flush This is a specialised mounting situation which will be encount...

Страница 17: ...or both brackets if necessary 6 Attach the brackets to the rear of the loudspeaker using the M5 x 12 pan head screws and shakeproof washers supplied The 10 mm diameter holes allow screwdriver access t...

Страница 18: ...tion the wiring scheme as indicated in fig 8 2 can be used Note that the application dependent safety regulations should be consulted in order to determine the proper grounding scheme Tap Setting The...

Страница 19: ...frequency response of the high pass filter is indicated in fig 10 2 Model V90 respectively fig 10 4 Model H90 The filter response is slightly dependent on the tap setting the curves are valid for the...

Страница 20: ...nes of other frequencies and or levels may be used if the fault monitoring system demands them the illumination of the LED is not essential for such a system to operate correctly Speaker Protection In...

Страница 21: ...Intellivox hinge bracket 90 RAL 9007 802005 Intellivox swivel bracket 90 RAL 9007 806668 Intellivox swivel bracket 45 RAL 9007 806678 Intellivox wall bracket set 2 pcs 25 mm RAL 9010 802225 Intellivox...

Страница 22: ...AXYS Intellivox ADC Installation Manual 22 201509 ADCIM This page has been left blank intentionally...

Страница 23: ...AXYS Intellivox ADC Installation Manual 23 201509 ADCIM This page has been left blank intentionally...

Страница 24: ...DURAN AUDIO BV Koxkampseweg 10 5301 KK Zaltbommel The Netherlands tel 31 418 515583 fax 31 418 518077 http www duran audio com Info duran audio com...

Отзывы: