Harman AMX NX-2200 Скачать руководство пользователя страница 2

© 2015 Harman. All rights reserved. NetLinx, WebControl, AMX, AV FOR AN IT WORLD, and HARMAN, and their respective logos are registered 

trademarks of HARMAN. Oracle, Java and any other company or brand name referenced may be trademarks/registered trademarks of their 

respective companies.
AMX does not assume responsibility for errors or omissions. AMX also reserves the right to alter specifications without prior notice at any time.
The AMX Warranty and Return Policy and related documents can be viewed/downloaded at www.amx.com.

3000 RESEARCH DRIVE, RICHARDSON, TX 75082 AMX.com | 800.222.0193 | 469.624.8000 | +1.469.624.7400 | fax 469.624.7153
AMX (UK) LTD, AMX by HARMAN - Unit C, Auster Road, Clifton Moor, York, YO30 4GD United Kingdom • +44 1904-343-100 • www.amx.com/eu/

 93-2106-02  REV: G

Last Revised: 12/28/2015

Accessing the WebConsole

NetLinx Masters have a built-in WebConsole that allows you to make various 

configuration settings via a web browser on any PC with access to the Master.
The WebConsole consists of a series of web pages that are collectively called the 

“Master Configuration Manager”. Refer to the 

NX Series NetLinx Integrated Controllers 

WebConsole & Programming Guide

 for details on the WebConsole.

From any PC with access to the LAN that the target Master resides on:
1.

Open a web browser and type the IP Address of the target Master in the Address 

Bar.

2.

Press 

Enter

 to access WebConsole for the Master. The initial view is the 

WebControl page.

FIG. 3  

WEBCONSOLE (MAIN PAGE)

Default Settings

The following sections list the default settings for the controller.

Default User Names and Passwords

The following table lists the default user names and passwords for accessing the 

NX-2200 through NetLinx Studio or the WebConsole.

Default IP Addresses

The following table lists the default IP addresses for the NX-2200.

Configuration

All items in this section require accessing the WebConsole.

Enabling Security

To enable security:
1.

Select the 

Security

 tab on the WebConsole. The System Security Details appear.

2.

Click the 

Enabled

 check box to enable security and activate the Access options.

3.

Select the Access options which you want to require a login and password.

4.

Configure users and groups as necessary.

Wired 802.1x Security

The X-Series controllers support wired 802.1x, an IEEE Standard for Port-based 

Network Access Control. To enable wired 802.1x, you must load an 802.1x certificate 

file to your controller using NetLinx Studio. Once you add the certificate file to your 

workspace, NetLinx Studio transfers the file to the appropriate directory on the 

controller.
1.

Click to select (highlight) a System (in the Workspace tab of the Workspace Bar).

2.

Right-click on the 

Other

 folder to access the Other File Folder context menu, and 

select 

Add Existing Other File

.

3.

In the Add Existing Other File dialog, locate and select the certificate file (.crt) that 

you want to add to the selected System. Change the Files of Type option to All 

Files (*.*) to look for other file types, if necessary.

4.

Click 

Open

 to access the File Properties dialog, where you can view/edit general 

file information for the selected file.

5.

Click 

OK

 to add the file to the selected System. The file should now appear in the 

Other folder under the selected System.

Setting the Clock Manager Mode

To set the clock manager mode:
1.

On the Manage System tab, select a Time Sync option.

• Network Time: When this option is selected, the Master will connect to the default 

NIST Server to get date and time information. You can select a different NIST 

Server (or specify the IP Address of a known NIST Server) on the NIST Servers 

tab.

• Stand Alone: This option lets the Master use its own internal clock. When this 

option is selected, the Date and Time fields are available on this tab.

2.

Click 

Accept

 to save these settings to the Master.

Hardware Information

This section lists important hardware information for the NX-2200.

Port Numbers

Mounting the NX-2200

The NX-2200 ships with removable rack ears for installation into an equipment rack. 

Use the supplied #8-32 screws to secure the rack ears to the sides of the controller. You 

can attach the rack ears toward the front or rear panel for either a front-facing or 

rear-facing installation.
Use the four #10-32 screws supplied in the mounting kit to secure the controller to the 

rack.

DEFAULT USER NAMES AND PASSWORDS

User Name

Password

NetLinx Studio

netlinx

password

WebConsole

administrator

password

DEFAULT IP ADDRESSES

IP Address

Subnet

Static IP

192.168.1.3

255.255.255.0

ICSLAN

198.18.0.1

255.255.0.0

Link-local

169.254.x.y, where x and y are the least significant two octets of the MAC 

address.

NX-2200 PORT NUMBERS

RS-232

RS-422/485

IR/Serial

I/O

Relay

2-4

1

11-14

22

21