Appendix A: NetLinx Control

29

 N1512 Windowing Processor User Manual

Appendix A: NetLinx Control

Introduction

NetLinx Studio is commonly used by system programmers to streamline the integration, programming, organization, and support 

of their AMX equipment. As the cornerstone of AMX's system design software tools, NetLinx Studio offers programmers the most 

flexible application capable of generating the most sophisticated code possible. Now equipment in our latest N-Series Networked 

AV Product comes equipped with NetLinx support. This addendum introduces the new configuration aspects necessary to bring all 

of your NetLinx-compatible equipment up to speed with the latest functionality. This addendum covers NetLinx functionality as it 

applies to AMX’s N-Series product line - specifically the N1512 Windowing Processor - and is designed to be used as a supplement 

to additional product documentation found on our website at 

http://www.amx.com/techcenter/manuals.asp

.

Common Applications

NetLinx Studio is a Microsoft Windows program that integrates programming, organization, and support into one application for 

NetLinx system development.

NetLinx Configuration Using the Unit’s Webpage 

From any main page of the unit webpage, click the 

NetLinx

 tab. See 

Figure 22

Table 9

 provides descriptions for each configuration 

option. 

FIG. 22  

NetLinx Configuration Page

Click here to access NetLinx 

configuration options.

Configuration options available will depend 

on which 

Master Mode

 you choose. See 

Table 9

 for more details.

TABLE 9  

NetLinx Configuration Options

Command

Description

Enable

Click to enable/disable NetLinx on this device.

Device Status

This status field will show the device to be 

Online

Connected

Offline

, or 

Unknown

.

Master Mode

Select 

Auto

Listen

, or 

URL

.

IP/URL

Enter the address of the Master Controller.

Port

This field should always be set to 

1319

.

Device Number

Defaults to a dynamic device number. May be set to a static range (e.g., 8000).

Содержание AMX NMX-WP-N1512

Страница 1: ...USER MANUAL N1512 4X1 WINDOWING PROCESSOR HIGH RESOLUTION WINDOW PROCESSING OVER AN ETHERNET LAN NMX WP N1512...

Страница 2: ...outlet 10 PROTECT the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 ONLY USE attachments accessories spec...

Страница 3: ...rient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connec...

Страница 4: ...ssigning IP Addresses Individually using the Settings page 14 Option 2 Assigning IP Addresses to Multiple Units using CSV files 15 Control Options 15 Primary Control Options 15 N Command Controllers 1...

Страница 5: ...5 N1512 Windowing Processor User Manual Native Commands Port 1 31 Windowing Processor Pass Through Command Examples 32 Appendix B Minimum Network Requirements 33...

Страница 6: ...ected to active streams IMPORTANT To avoid creating a network loop never connect more than one P port to the same network segment To achieve larger stacked configurations additional Windowing Processo...

Страница 7: ...o reset but not lose power A reset does NOT affect the current settings Press and hold for 30 seconds to perform a factory restore Diagnostic LEDs LEDs 0 3 Lower row On solid green signifies receipt o...

Страница 8: ...r New N1512 Windowing Processor 8 N1512 Windowing Processor User Manual Application Example FIG 2 Windowing Processor Application Example Note Single line represents four independent connections from...

Страница 9: ...rovided here assume the following to be true 1 There are switches operational on the network N Series equipment can operate on many different brands of networking equipment The network itself needs to...

Страница 10: ...cally based on the network DHCP server If no DHCP server is found the unit will switch to Auto IP mode with a default IP address of 169 254 xxx xxx Before beginning installation you will need to make...

Страница 11: ...units in Auto IP mode will not self assign in the 169 254 0 xxx range NOTE If the computer has a statically assigned IP address click the Advanced button Then click Add to enter a unique 169 254 xxx...

Страница 12: ...r launch N Able to view all discovered units The N1512 units appear on the following tabs Unit Management tab Windowing Processor is listed in the Type field Video Matrix tab N1512 units are found on...

Страница 13: ...ce logged in you can change the password using the options on the Unit Settings page The Login page is only displayed if N Able s stored username password does not match the unit s username password A...

Страница 14: ...units using N Able Option 1 Log in to each unit individually and make the changes on the Unit Settings page Option 2 Export a comma separated value CSV file make changes to all units in the resulting...

Страница 15: ...t Control Options N Series control solutions N Command N Act and N Touch provide you with the most flexible management options available insuring you are getting the most from your digital media syste...

Страница 16: ...the Windowing Processor web interface refer back to the Logging in to the Windowing Processor s Web Interface section on page 13 From any main page in the GUI you can access all other main pages by c...

Страница 17: ...ging and dropping resizing etc You can fine tune adjustments by directly entering values in the fields on the right side of the screen Number tabs 1 4 Select the window for which you would like to vie...

Страница 18: ...rrange windows into one of the factory pre set choices Load Custom Preset dropdown Click to automatically arrange windows into one of the custom pre set choices saved to this Windowing Processor Backg...

Страница 19: ...Zoom Page Options Option Description Window Number tabs 1 4 Select the window for which you would like to view edit settings X1 Y1 Set pixel coordinates of cropping area top left X2 Y2 Set pixel coor...

Страница 20: ...to access the page shown in Figure 11 The Unit Settings page is divided into several sections Refer to the following sections for detailed descriptions Unit Setup Section on page 21 Stored Presets Sec...

Страница 21: ...rocessor Enable this option prior to viewing the output of the N1512 with a Decoder When enabled you can route AV streams in N Able or your other configuration choice to the four windows and route the...

Страница 22: ...t have MPC support Output Sync Enable to sync the Windowing Processor video output to the video stream input given by the Sync Stream setting described next Sync Stream Enter the video stream number t...

Страница 23: ...box Enable this checkbox if you want to append the current stored presets with the imported presets If this option is not enabled the import will overwrite the currently stored presets TABLE 6 Unit Se...

Страница 24: ...ssword for admin level access enter the current password in the field labeled Old Password and enter a new password in the New Password and Confirm Password fields Click Change PW to accept the new pa...

Страница 25: ...Sys Description Port ID and Port Description fields all reflect the information that was entered on the connected switch s web interface FIG 19 LLDP Page TABLE 8 Unit Settings Page Software Section O...

Страница 26: ...shown in Figure 20 The Logs page displays a command log that lists all TCP and UDP messages the unit receives It also displays the web browser s IP address and gives you options to Refresh and Reset...

Страница 27: ...l NetLinx Page Click the NetLinx link at the top of any of the main web pages to access the page shown in Figure 21 This page allows you to prepare your Windowing Processor for NetLinx driven configur...

Страница 28: ...d sources connected to all four U ports Are the AV sources properly routed to windows of the N1512 Is the network configured appropriately for N1000 AV traffic Did you assign unique IP addresses for e...

Страница 29: ...tional product documentation found on our website at http www amx com techcenter manuals asp Common Applications NetLinx Studio is a Microsoft Windows program that integrates programming organization...

Страница 30: ...e NetLinx On button and click the OK button at the bottom of the screen FIG 24 Enabling NetLinx on Multiple Units NOTE Items are not filtered In other words if you send a NetLinx command to a device t...

Страница 31: ...st be sent to D P S port 1 Syntax SEND_COMMAND DEV CA stream Variables stream The target stream number from 0 to 32767 Set to 0 for the audio stream to follow the video stream Examples SEND_COMMAND 50...

Страница 32: ...1 960 0 1919 539 SEND_STRING DEV setz 1 2 SEND_STRING DEV winon 2 SEND_STRING DEV set 2 stream window 2 SEND_STRING DEV setbordcol 2 255 255 255 SEND_STRING DEV bordoff 2 SEND_STRING DEV winset 2 0 5...

Страница 33: ...iate Leave also know as Fast Leave etc depending on switch manufacturer NOTE If Immediate Leave is disabled set IGMP Robustness to Default 2 Robustness can be adjusted generally from 2 10 The higher t...

Страница 34: ...sponsibility for errors or omissions AMX also reserves the right to alter specifications without prior notice at any time The AMX Warranty and Return Policy and related documents can be viewed downloa...

Отзывы: