To avoid ESD (Electrostatic Discharge) damage to sensitive components, make sure you are properly grounded before 

touching any internal materials. 
When working with any equipment manufactured with electronic devices, proper ESD grounding procedures must be 

followed to make sure people, products, and tools are as free of static charges as possible. Grounding straps, conductive 

smocks, and conductive work mats are specifically designed for this purpose. 
Anyone performing field maintenance on AMX equipment should use an appropriate ESD field service kit complete with at 

least a dissipative work mat with a ground cord and a UL listed adjustable wrist strap with another ground cord. 

WARNING

: Do Not Open! Risk of Electrical Shock. Voltages in this equipment are 

hazardous to life. No user-serviceable parts inside. Refer all servicing to qualified 

service personnel. 
Place the equipment near a main power supply outlet and make sure that you can 

easily access the power breaker switch. 

 

This appliance is labeled in accordance with European Directive 2012/19/EU concerning waste of electrical and electronic 

equipment (WEEE). This label indicates that this product should not be disposed of with household waste. It should be 

deposited at an appropriate facility to enable recovery and recycling. 

 

 

ESD WARNING

 

 

WARNING

: This product is intended to be operated ONLY from the voltages listed on the back panel or the recommended, or 

included, power supply of the product. Operation from other voltages other than those indicated may cause irreversible 

damage to the product and void the products warranty. The use of AC Plug Adapters is cautioned because it can allow the 

product to be plugged into voltages in which the product was not designed to operate. If the product is equipped with a 

detachable power cord, use only the type provided with your product or by your local distributor and/or retailer. If you are 

unsure of the correct operational voltage, please contact your local distributor and/or retailer. 

FCC AND CANADA EMC COMPLIANCE INFORMATION:

 

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 

(1)

 

This device may not cause harmful interference, and (2) this device must accept any interference received, including 

interference that may cause undesired operation. 

NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of 

the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential 

installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in 

accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee 

that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or 

television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct 

the interference by one or more of the following measures: 

•Reorient or relocate the receiving antenna. 
•Increase the separation between the equipment and receiver. 
•Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 
•Consult the dealer or an experienced radio/TV technician for help. 

Approved under the verification provision of FCC Part 15 as a Class A Digital Device. 
Caution: Changes or modifications not expressly approved by the manufacturer could void the user's authority to operate this 

device. 
CAN ICES-3 (B)/NMB-3(B) 

EU COMPLIANCE INFORMATION:

 

Eligible to bear the CE mark; Conforms to European Union Low Voltage Directive 2006/95/EC; European Union EMC Directive 

2004/108/EC; European Union Restriction of Hazardous Substances Recast (RoHS2) Directive 2011/65/EU. 
You may obtain a free copy of the Declaration of Conformity by visitin

http://www.amx.com/techcenter/certifications.asp

WEEE NOTICE:

 

Содержание AMX NMX-ENC-N2312

Страница 1: ...INSTRUCTION MANUAL N2300 SERIES N2312 ENCODERS N2322 DECODERS DIGITAL MEDIA DISTRIBUTION SWITCHING SOLUTION NMX ENC N2312 NMX DEC N2322...

Страница 2: ...of important operating and maintenance servicing instructions in the literature accompanying the product The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert t...

Страница 3: ...r retailer If you are unsure of the correct operational voltage please contact your local distributor and or retailer FCC AND CANADA EMC COMPLIANCE INFORMATION This device complies with part 15 of the...

Страница 4: ...ge 18 Option 2 Assigning IP Addresses to Multiple Units using CSV files 18 Switching and Scaling Options 20 Seamless Switching 20 Control Options 21 Primary Control Options 21 N Command Controllers 21...

Страница 5: ...Page 52 Logs Page 52 Security Page 53 EDID Page 53 LLDP Page 54 NetLinx Page 54 Chapter 5 Troubleshooting 56 Series Default Local Host Play Troubleshooting Screens 57 Appendix A NetLinx Control 59 In...

Страница 6: ...nd Decoders Input and output scaling performed in Encoders or Decoders for maximum flexibility Power over Ethernet PoE eliminates the need for a local power supply and speeds installation Units can st...

Страница 7: ...coder 33 60 kHz typically 39 kHz IR receiver required not included ID button Recessed pushbutton Press to send notification out on the network to identify the unit the notification causes a pop up dia...

Страница 8: ...ector which provides a serial control interface Full duplex communication Available terminal speed settings 1200 to 115200 baud rate AUDIO 5 pin terminal Phoenix connector which provides user selectab...

Страница 9: ...a digital source connect the source to the Encoder s HDMI IN port using a video cable with an HDMI connector or adapter For video encoding of an analog source connect the source to the Encoder s VGA...

Страница 10: ...d Connecting Encoders to the Network and Configuring Stream Settings on page 15 for more information on these connections FIG 5 Installing Mounting Wings Rack Mounting N2300 Series Stand Alone Units A...

Страница 11: ...ure8 FIG 8 Fully Populated Card Cage 6 For proper airflow cover any unused card slots with faceplate blanks Blanks are sold separately part number N9210 7 Make sure the Card Cage s power cord is plugg...

Страница 12: ...y network segment or link Matrix switches as large as 1200x800 have been constructed on a house network using N Series equipment Alternatively many customers choose to deploy on physically separate ne...

Страница 13: ...ent N2312 N2322 User Manual 13 4 Scroll down in the list to the Internet Protocol Version 4 TCP IPv4 option Highlightit and click the Properties button 3 Double click the wiredinterface to your AV net...

Страница 14: ...nd output on the HDMI ports however some display devices e g many monitors do not support embedded audio When using such a display use the AUDIO port for separate transmission of sound and turn HDMI A...

Страница 15: ...to a PoE enabled switch In non PoE applications connect a 12V regulated power supply N9312 to the two pin terminal block plug connector labeled 12V 2A NOTE In order for the unit to receive PoE it mus...

Страница 16: ...Video Matrix Page 4 Double click the Encoder s name in the list The Login page is displayed see Figure 12 If prompted use the following default login credentials to log in for the first time These can...

Страница 17: ...st connected to the network an IP address is assigned automatically based on the network DHCP server If no DHCP server is found the unit will use Auto IP mode with an IP address pre configured to 169...

Страница 18: ...Multiple Units using CSV f iles N Able has the ability to export and import CSV files Once units are auto discovered in N Able the CSV file can be exported into Excel where parameters such as IP addre...

Страница 19: ...escribed in Step 3 and Step 4 you can now connect to the appropriate AV source s This connection from an Encoder HDMI IN port female to an input source is accomplished using either an HDMI cable or DV...

Страница 20: ...t is 3840x2160 and the Decoder scaler is set to 1080p50 60 Any other attempts at downscaling are not recommended supported Seamless Switching The N2300 Series supports seamless switching capability if...

Страница 21: ...h video stream etc Additional software bundles free with N Command allow you to easily create attractive touch panels for N Series and third party equipment control as well as build software design wa...

Страница 22: ...d port 5 Using N Able click the Unit Management tab 6 Click the Auto Discover button to discover your new devices if you have not already done so 7 Once discovery is complete and you see the new units...

Страница 23: ...GUI you can access all other main pages by clicking the links in the top navigation bar Figure 17 shows the navigation bar and provides hot links to the sections of this chapter which describe each ma...

Страница 24: ...is page is divided into several sections and has links to other dialog boxes for additional configuration options Refer to the following sections for detailed descriptions Device Settings Section on p...

Страница 25: ...Encoder must have a unique stream number just like every channel must have a unique channel number e g Food Network and HGTV cannot both be on channel 201 Video Source Select which input port is encod...

Страница 26: ...N Able or N Command from occurring This does not prevent a control system from making changes or a user from manually making changes Gratuitous ARP Enable the Encoder to send a periodic Address Resol...

Страница 27: ...ables a multicast format which interleaves video and audio streams In order for N Series devices to communicate with each other their multicast settings must be compatible Discovery Packet Transmit En...

Страница 28: ...y entered DHCP is the default setting However using DHCP beyond initial setup is generally not recommended If the device is set to DHCP and fails to receive an address from the DHCP server in time it...

Страница 29: ...rce IP Shows the IP address of the currently connected device or displays Disconnected if no connection exists Port 50002 can only accept a single external connection at a time If a device is currentl...

Страница 30: ...version Displays the date code for the currently running version of the web interface Kernel Displays the current kernel revision Factory Restore button Click to restore the device to the original fac...

Страница 31: ...des more information on HostPlay option descriptions FIG 25 HostPlay Page TABLE 7 HostPlay Page Options Option Description Playlists 1 8 View the images assigned to each of the eight PlayLists On the...

Страница 32: ...Application Programming Interface API commands Video Cable Connected Event Create delete test events to be performed when the Encoder is connected to a video source The Trigger Delay field specifies h...

Страница 33: ...urn a No Data message and fail to send the commands Also if NetLinx is enabled then the Serial web page shown below is inactive FIG 27 Serial Page TABLE 9 Serial Page Options Option Description Serial...

Страница 34: ...a web search Copy paste new IR commands directly into the input space Save button Save the current code Delete button Delete the current code Execute button Activate the selected code through the Enc...

Страница 35: ...ecurity Page EDID Page Click the More link at the top of any of the main web pages and select EDID to access the page shown in Figure 31 Every display has stored information that it communicates to th...

Страница 36: ...tal EDID button This overwrites the existing EDID To return to the Encoder s default click Reset Digital EDID NOTE The source will need to be disconnected while modifying EDID settings Analog EDID sec...

Страница 37: ...eb pages and select NetLinx to access the page shown in Figure 33 Options are described in Table 12 This page allows you to prepare your N2312 Encoder for NetLinx driven configuration This is explaine...

Страница 38: ...to connect This setting is dependent upon the Master Mode selected see above If Master Mode is set to Auto the System Number is set and the system discovers the Central Controller s IP address If Mast...

Страница 39: ...section on page 23 you can access the GUI main pages by clicking the links in the top navigation bar Figure 34 shows the navigation bar and provides hot links to the sections of this chapter which des...

Страница 40: ...page is divided into several sections and also has links to other dialog boxes for additional configuration options Refer to the following sections for detailed descriptions Device Settings Section o...

Страница 41: ...AV matrix Each decoder can dial in a different active channel Audio Stream View edit the current audio receive stream number Audio Follows Video Enable to force the Audio Stream to the same as the vid...

Страница 42: ...4 Settings Page Advanced Settings Option Description Notes Settings Lock Enable to lock the Decoder IP settings and stream number preventing automated processes from N Able or N Command from occurring...

Страница 43: ...w long until the command is repeated IGMP Joins on Stream Loss Enable to send Internet Group Management Protocol IGMP join messages when no incoming stream is detected IGMP Join Interval Delay in seco...

Страница 44: ...12 N2322 User Manual 44 Option Description Notes Disable P1 Completely disables the P1 port for all traffic Once disabled anything connected to the P1 port will no longer be available on the network S...

Страница 45: ...ually entered DHCP is the default setting However using DHCP beyond initial setup is generally not recommended If the device is set to DHCP and fails to receive an address from the DHCP server in time...

Страница 46: ...the IP address of the currently connected device or displays Disconnected if no connection exists Port 50002 can only accept a single external connection at a time If a device is currently showing th...

Страница 47: ...version Displays the date code for the currently running version of the web interface Kernel Displays the current kernel revision Factory Restore button Click to restore the device to the original fac...

Страница 48: ...d to the wall area auto Decoder decides the best scaling method fit Fits the video to the wall area changing the aspect ratio as needed stretch Stretches the video to fill the wall maintaining the asp...

Страница 49: ...1 See Table 21 for option descriptions FIG 43 LocalPlay Page TABLE 21 LocalPlay Page Options Option Description Playlist 1 8 View the images assigned to each of the eight PlayLists On the Settings pag...

Страница 50: ...plication Programming Interface API commands Video Cable Connected Event Create delete test events to be performed when the Decoder is connected to an output display The Trigger Delay field specifies...

Страница 51: ...urn a No Data message and fail to send the commands Also if NetLinx is enabled then the Serial web page shown below is inactive FIG 45 Serial Page TABLE 23 Serial Page Options Option Description Seria...

Страница 52: ...a web search Copy paste new IR commands directly into the input space Save button Save the current code Delete button Delete the current code Execute button Activate the selected code through the Dec...

Страница 53: ...ecurity Page EDID Page Click the More link at the top of any of the main web pages and select EDID to access the page shown in Figure 49 Every display has stored information that it communicates to th...

Страница 54: ...eb pages and select NetLinx to access the page shown in Figure 51 Options are described in Table 26 This page allows you to prepare your N2322 Decoder for NetLinx driven configuration This is explaine...

Страница 55: ...to connect This setting is dependent upon the Master Mode selected see above If Master Mode is set to Auto the System Number is set and the system discovers the Central Controller s IP address If Mast...

Страница 56: ...o LocalPlay If the LocalPlay screen does not appear check the display input settings and cabling As mentioned previously in this table you can change to the Local mode on the Decoder s Settings page I...

Страница 57: ...g this screen means that the Decoder CAN communicate with the Encoder across the network It is a good way to troubleshoot network communication between segments using only Encoders and Decoders withou...

Страница 58: ...is transmittingHDCP protected content to the Decoder Once the Decoder detects that the monitor is not HDCP compliant this screen is displayed If you suspect that this message was displayed in error pl...

Страница 59: ...e specifically the N Series Encoders Decoders and is designed to be used as a supplement to additional product documentation found on our website at amx com support_downloads Common Applications NetLi...

Страница 60: ...this page Batch Configurations Using N Able One of the many benefits of using N Able control is batch configuration This is especially useful in larger deployments Instead of using the individual uni...

Страница 61: ...hat the stream number can be 0 no stream Examples SEND_COMMAND 5002 1 0 CI 2 Command the Decoder to receive stream 2 CA stream Set the current Decoder Audio stream number IMPORTANT This command must b...

Страница 62: ...D_COMMAND DEV REBOOT Variables None Examples SEND_COMMAND 5002 1 0 REBOOT Reboots the device VIDOUT_OUTPUT Request the Encoder current stream number Syntax SEND_COMMAND DEV VIDOUT_OUTPUT Examples SEND...

Страница 63: ...arity data stop Variables baud baud rates are 115200 57600 38400 19200 9600 4800 2400 1200 parity N none O odd E even data 8 data bits stop 1 and 2 stop bits Example SEND_COMMAND 5002 3 0 SET BAUD 960...

Страница 64: ...b page See Figure 58 to see where to find these options IR Command Holdoff This is the delay between IR commands portions To set the IR Command Holdoff issue the following string command SEND_STRING D...

Страница 65: ...able to have both Immediate Leave units and daisy chaining on the same VLAN NOTE If Immediate Leave is disabled set IGMP Robustness to Default 2 Robustness can be adjusted generally from 2 10 The hig...

Страница 66: ...ponsibility for errors or omissions AMX also reserves the right to alter specifications without prior notice at any time The AMX Warranty and Return Policy and related documents can be viewed download...

Отзывы: