Harman AMX NI-2100 Скачать руководство пользователя страница 28

Connections and Wiring

28

NI-2100/3100/4100 - Hardware Reference Guide

LAN Port Descriptions (Cont.)

Port type

Description

Standard Port #

ICSP

Peer-to-peer protocol used for both Master-to-Master and Master-to-device communications.
For maximum flexibility, the Master can be configured to utilize a different port than 1319, or disable 

ICSP over LAN completely from either Telnet or the Program Port located on the rear of the Master 

itself.
This type of communication is used by the various AMX product for communication amongst 

themselves.

1319 (UDP/TCP)

integration!

Solutions

This feature on the Master uses, by default, port 10500 for the XML based communication protocol. 

This port is connected to by the client web browser’s JVM when integration! Solutions control pages are 

retrieved from the on-board Master’s web server.
For maximum flexibility, the on-board Master can be configured to utilize a different port than 10500 or 

to disable integration! Solutions completely.

10500 (TCP)

Содержание AMX NI-2100

Страница 1: ...HARDWARE REFERENCE GUIDE NETLINX INTEGRATED CONTROLLERS NI 2100 NI 3100 NI 4100...

Страница 2: ...nd the point where they exit from the apparatus 11 ONLY USE attachments accessories specified by the manufacturer 12 USE ONLY with a cart stand tripod bracket or table specified by the manufacturer or...

Страница 3: ...allation of Compact Flash Upgrades 16 Closing and Securing the Outer Housing 17 Installing Into An Equipment Rack 17 Rack Mount Safety Instructions 17 Connections and Wiring 19 Setting the Configurati...

Страница 4: ...Hub OUT Port Connections and Wiring 24 Relay Port Connections and Wiring 25 Relay Connections 25 Input Output I O Port Connections and Wiring 25 IR Serial Port Connections and Wiring 26 NetLinx Contro...

Страница 5: ...easier by automatically identifying and communicating with devices which support this beaconing technology Features NI Controllers Features NI 2100 NetLinx Integrated Controllers Name FG Features NI...

Страница 6: ...standardizing device and function definitions default touch panel button assignments and control and feedback methods NI Controllers Features Cont NI 4100 NetLinx Integrated Controllers Name FG Featur...

Страница 7: ...ial channels 1 4 are transmitting control data on Ports 5 8 The LED indicator for each IR port remains lit for the length of time that IR Serial data is being generated I O yellow Lights when the I O...

Страница 8: ...tate of the AxLink port Power Port 2 pin 3 5 mm mini Phoenix male connector Operating Environment Operating Temperature 0 C 32 F to 50 C 122 F Operating Humidity 20 to 85 RH Heat Dissipation Typical 2...

Страница 9: ...3100 NI 3100 256 can be upgraded to provide one ICSHub and two ICSNet ports by installing the optional ICSNet daughter card FG2105 10 see Other AMX Equipment NI 3100 ICS 64MB Controller with ICSNet FG...

Страница 10: ...le of voltage sensing Input format is software selectable with interactive power sensing for IR ports IR Serial Ports 9 16 8 IR Serial control ports support high frequency carriers of up to 1 142 MHz...

Страница 11: ...te installed control card firmware NOTE Verify you are using the latest NI firmware for the on board Master Verify you are using the latest version of NetLinx Studio available for download from www am...

Страница 12: ...nels 1 8 are active The LED for each I O port reflects the state of that particular port NetLinx Control Card Slots 1 4 Accepts up to 4 compatible NetLinx Cards NXC COM2 NXC I O10 etc Rear Panel Compo...

Страница 13: ...rol devices Green AxLink LED indicates the state of the AxLink port Power Port 2 pin 3 5 mm mini Phoenix male connector CardFrame DIP Switch Sets the starting address for the Control Cards in the Card...

Страница 14: ...100 Only The 8 position CardFrame Number DIP switch located on the rear of the NI 4100 sets the starting address the device number in the D P S specification for the Control Cards installed in the Car...

Страница 15: ...ts 5 Re secure the faceplate by inserting the three faceplate screws by turning them in a clockwise direction and securing the front plate to the Integrated Controller 6 Re apply power and other conne...

Страница 16: ...rd and gently pry the card out of the slot Repeat this process on the opposite card removal groove This alternating action causes the card to wiggle away from the on board connector pins 4 Slip your f...

Страница 17: ...k should be such that the amount of air flow required for safe operation of the equipment is not compromised Mounting the equipment in the rack should be such that a hazardous condition is not achieve...

Страница 18: ...g the installation test the incoming wiring by connecting the Controller s connectors to their terminal locations and applying power Verify that the unit is receiving power and functioning properly Di...

Страница 19: ...or control problems If necessary place the on board Master in PRD mode and use the NetLinx Studio program to resolve the communication and or control problems with the resident NetLinx program Then d...

Страница 20: ...needed pins Modes and Front Panel LED Blink Patterns The following table lists the modes and blink patterns for the front panel LEDs associated with each mode These patterns are not evident until afte...

Страница 21: ...ower supply to provide power through the rear 2 pin 3 5 mm mini Phoenix PWR connector Use the power requirements referenced in the product s Specifications table to determine the power draw The incomi...

Страница 22: ...2 pin 3 5 mm mini Phoenix cable Match the wiring locations of the on both the power supply and the terminal connector 2 Tighten the clamp to secure the two wires Do not tighten the screws excessively...

Страница 23: ...figure gives a visual representation of the wiring specifications for the RS 232 422 485 Device connectors Refer to the rear of the unit for more detailed connector pinout information The table below...

Страница 24: ...re bi directional ICSHub OUT Port Connections and Wiring The NI Controller must be equipped with the available ICSNet connectors for this functionality to be active The following table describes the p...

Страница 25: ...V without harm When used for outputs the I O port acts as a switch to GND and is rated for 200mA 12 VDC The NI 2100 can use up to 4 I O ports The NI 3100 and NI 4100 can use up to 8 I O ports The PWR...

Страница 26: ...using a short cable length 10 feet NetLinx Control Card Slot Connector NI 4100 only FIG 16 shows the 20 pin male connector that provides connection to the NetLinx Control Cards FIG 15 IR SERIAL male I...

Страница 27: ...it uses SSL as a mechanism to configure and diagnose a NetLinx system This port value is used for secure Telnet communication Note SSH version 2 is only supported 22 TCP Telnet The NetLinx Telnet serv...

Страница 28: ...m Port located on the rear of the Master itself This type of communication is used by the various AMX product for communication amongst themselves 1319 UDP TCP integration Solutions This feature on th...

Страница 29: ...assume responsibility for errors or omissions AMX also reserves the right to alter specifications without prior notice at any time The AMX Warranty and Return Policy and related documents can be view...

Отзывы: