Encoder Configuration Options
34
N2312/N2322 User Manual
IR Page
Click the
IR
link at the top of any of the main web pages to access the page shown in
. This page allows you to upload and
execute IR Pronto codes so that other vendor’s devices can be controlled through the Encoder’s IR connector. Commands can be
saved for future use and executed later. The
IR Code
menu lists all saved IR commands. See
for option descriptions.
FIG. 28
IR Page
Logs Page
Click the
More
link at the top of any of the main web pages and select
Logs
. The
Logs
page
displays a command log that lists all TCP and UDP messages the unit receives. It also displays the web browser’s IP address and
gives you options to
Refresh
and
Reset
Logs
. When in need of assistance from tech support, use the
Debug
Log
section to capture
information useful for troubleshooting. Simply click
Start
Debug
Log
, wait at least one minute, and click
End
Debug
Log
to create
the file. You can then download and send it to tech support.
FIG. 29
Logs Page
TABLE 10
IR Page Options
Option
Description
IR Code
Create/select IR codes. Different vendors have different IR Pronto codes and can usually be found through a web
search. Copy/paste new IR commands directly into the input space.
Save button
Save the current code.
Delete button
Delete the current code.
Execute button
Activate the selected code through the Encoder’s
IR
connector.