Settings Pages
39
Modero G4 Touch Panels - Configuration & Programming Manual
Security Profile Features
Each of the settings on this page has different features for touch panel security:
A transition from one security mode to another will reset the Protected/Web Control/remote login password to the default value for
the current security mode (please refer to the default passwords above). A transition to Secure or DoD mode will disable G4 Web
Control. Although the security password features are immediate, a reboot must occur for all the new security mode features to take
full effect.
NOTE:
Changing the security setting will also change the G4 Web Control password. This must be reset from the G4 WebControl
before you can access the panel via VNC.
Install Firmware
The
Install Firmware
page (FIG. 51) allows the touch panel to be reloaded with its original factory-loaded firmware, installed with a
previous version of the current firmware, or to install new firmware from an external storage disk, such as a USB stick.
Resetting to Factory-Installed Firmware
In certain circumstances, it may be necessary to uninstall the current firmware on a touch panel and return the panel to its original
factory default firmware. To reset the touch panel to its original factory firmware via the
Settings
pages:
1.
From the
Install Firmware
page, select the
Factory
field.
2.
A System Message window appears, asking “Are you sure you want to install the following firmware?”, with the version
“Factory Firmware” listed below (FIG. 52).
Security Profile Features
Standard:
• Factory default, shipped in this configuration.
• Default Password is
1988
.
• Remote login uses Telnet.
Secure:
• Default Protected Setup Password is
Amx1234!
.
• Minimum password requirement is 8 characters with at least one numeric character.
• Remote login uses SSH.
• Remote login user name is
amx
.
• Login failure attempt pauses 4 seconds before another login attempt is allowed.
• After 3 consecutive unsuccessful SSH login attempts, login lockout is enabled for 15 minutes.
• Login and logout audit logging is enabled.
DoD:
• Default Protected Setup Password is
Amx1234!
.
• Minimum password requirement is 8 characters with at least one numeric character, one uppercase character, one lower
case character, and one special character, with no duplicate adjacent characters.
• Remote login uses SSH.
• Remote login user name is
amx
.
• Login failure attempt pauses 4 seconds before another login attempt is allowed.
• After 3 consecutive unsuccessful SSH login attempts, login lockout is enabled for 15 minutes.
• Login and logout audit logging is enabled.
• DoD login banner is enabled.
FIG. 51
Install Firmware page
Install Firmware Page
Factory:
Select this to revert the panel back to its original factory-loaded firmware.
Previous:
Select this to re-install the last previously loaded firmware version.
New:
Select this to install new firmware from an external disk, such as from a USB stick.
Note: if the panel does not detect an external disk containing firmware, this will be greyed out.