![Harman AMX DXLINK DX-TX-DWP-4K Скачать руководство пользователя страница 43](http://html1.mh-extra.com/html/harman/amx-dxlink-dx-tx-dwp-4k/amx-dxlink-dx-tx-dwp-4k_hardware-reference-manual_4033893043.webp)
IRL File Transfers
43
Hardware Reference Manual – DXLink™ Twisted Pair 4K Transmitters/Receivers
IRL File Transfers
Overview
IMPORTANT:
The information in this Chapter does not pertain to any of the 4K HDMI Wallplate TX as the device does not provide IR
communication ports.
The NetLinx Studio software application (available for free download from www.amx.com) provides the ability to transfer IR Library
files to NetLinx devices such as DXLink Modules.
When a DXLink Module is being used in conjunction with a switcher, the switcher’s integrated Master is used for the IRL file transfer.
FIG. 24 shows a Receiver Module bound to the integrated Master in an Enova DGX 1600 in NetLinx Studio’s OnLine Tree. Follow the
instructions on the top of page 43 to prepare for IRL file transfer and the instructions on page 44 for the actual transfer.
Preparing for IRL File Transfers
To prepare for IRL file transfers:
1.
Check to be sure #3 Toggle on the bottom of the Module is set to ON.
2.
Verify that you have the latest version of NetLinx Studio on your PC.
If the version is not the latest
–
Use the Web Update option in NetLinx Studio’s Help menu to obtain the latest version.
Or
Go to www.amx.com and login as a Dealer to download the latest version.
3.
Download the applicable IRL file from www.amx.com (Partners / Search Devices) to your PC.
4.
Verify the following:
a.
Verify that an Ethernet/RJ-45 cable is connected from the switcher’s integrated Master to the network (e.g., from the
LAN 100/1000 port on the Enova DGX to a LAN).
b.
Verify that the target Module is connected via its DXLink connector to a DXLink Input or Output Board (respectively) on
the switcher.
c.
Verify that the switcher is powered on.
5.
Launch NetLinx Studio and open the OnLine Tree.
6.
Bind the target Module to the integrated Master:
a.
Select and right-click the Module in the Online Tree.
b.
From the context sensitive menu, select Network Bind/Unbind Device.
c.
Verify that the check box is selected. If not selected, select it now.
FIG. 24
NetLinx Studio – Integrated Master, Enova DGX 1600, and DXLink Receiver
Ports 1-7 on DXLink Receiver
Device number
DXLink Receiver
Enova DGX 3200
Integrated Master