32
USER MANUAL - DUX-8D
IDX Function
Command
Example
Action
1
To execute a
switch
CL#O#I#T
I#: #={0 ~8 }
O#: #={1~8, ALL}
Command:
CO8I2T
Return:
CO8I2T
Switches Input 2
to Output 8 on the
default level (normally
Level 0)
Command:
CO4:8I2T
Return:
CO4:8I2T
Switches Input 2 to
Outputs 4,5,6,7,8 on
Level 0
Command:
CO1:3 5 7:8I2T
Return:
CO1:3 5 7:8I2T
Switches Input 2 to
Outputs 1,2,3,5,7,8 on
Level 0
Command:
COALLI2T
Return:
COALLI2T
Switches Input 2 to All
Outputs
Command:
CO8I0T
Return:
CO8I0T
Disconnects output 8
(Switches none input
to Output 8)
2
To verify signal
status
SL#O#T
O#: #={1~8}
Command:
SO4T
Return:
SO4T( 6 )
Output 4 is connected
to input 6 on Level 0
Command:
SO8T
Return:
SO8T( )
Output 8 is not
connected to an input
on Level 0
SL#I#T
I#: #={1~8}
Command:
SI4T
Return:
SI4T( 1 2 6 )
Input 4 is routed to
outputs 1,2, and 6 on
Level 0
Command:
SI8T
Return:
SI8T( )
input 8 is not routed to
an output on Level 0