Harman AMX AXB-232++ Скачать руководство пользователя страница 5

AXB-232++

5

AXB-232++ - Instruction Manual

AXB-232++

Overview

The AXB-232++ RS-232/422/485 Interface (FG5761-10) is an AxLink bus controller that provides remote control for devices that 

require a variety of control protocols. The AXB-232++ extends RS-232, RS-422, or RS-485 control to remote sources over the 4-

wire AxLink data/power bus. Onboard processing and memory allows the controller to take on complex tasks by itself, reducing the 

processing burden for the Axcess control system. For example, the control system can use simplified commands for generic video 

switcher or code control, a modular driver program in the AXB-232++ can process control for specific makes and models. 

Specifications

The following table lists the specifications for the AXB-232++.

FIG. 1  

AXB-232++ front panel

Specifications

Power

12 VDC @ 160 mA

Processor

On board 32-bit processor and 384K (of non-volatile memory) run Axcess programs independent of the 

control system. This relieves the AxLink bus and controller for the processing time for controlling those 

devices. (Requires Axcess Version 3.0 or higher.)

Asynchronous data 

standards

• Baud rates - 

300

600

1200

2400

4800

9600

19200

 and 

38400

56400

 is supported via the BAUDMED Send Command (see the 

Send_Commands

section on page 12 fo

details).

115200

 is supported via the BAUDHIGH Send Command (see the 

Send_Commands

section on page 12 for 

details).

• Data bits - 7, 8, and 9
• Stop bits - 1 and 2
• Parity - 

None

Odd

Even

Mark

 and 

Space

Buffers

• 1KB input buffer
• 1KB AxLink buffer

Front Panel

AxLink LEDs

Green AxLink status indicator:

Full-Off 

indicates no power is being received or the controller is not functioning properly.

One blink per second

 power is active and AxLink communication is functioning.

Full-On

 indicates power is active and AxLink data communication is not functional.

RX LED (Red)

Blinks to indicate the AXB-232++ is receiving RS-232, RS-422, or RS-485 data.
The RX LED blinks even if the data being received is incorrect.

TX LED (Red)

Blinks to indicate the AXB-232++ is sending RS-232, RS-422, or RS-485 data.

DEVICE DIP Switch

An eight-position DIP switch used to set the device number for the AXB-232++. Refer to 

Setting the DEVICE 

DIP switch, on 

page 8, and 

Setting Jumper JP5 To Set the RS-422 Port For RS-485 Use

section on page 7 for 

more information.

RS232/422 DIP Switch An eight-position DIP switch used to set the communication parameters for the RS-232/422 device. Refer to 

Setting the RS-232/422 DIP switch

, on page 8, for more information.

Front

Rear

Содержание AMX AXB-232++

Страница 1: ...INSTRUCTION MANUAL AXB 232 RS 232 422 485 INTERFACE...

Страница 2: ...nd the point where they exit from the apparatus 11 ONLY USE attachments accessories specified by the manufacturer 12 USE ONLY with a cart stand tripod bracket or table specified by the manufacturer or...

Страница 3: ...S 232 422 DIP Switch 8 Wiring Devices to the AXB 232 9 Preparing Captive Wires 9 Wiring Guidelines 9 Using AxLink 9 Using AxLink and External Power Supply 9 Using RS 232 9 Using Hardware Handshaking 1...

Страница 4: ...Send_String Escape Sequences 14 27 17 time 14 27 18 1 14 27 18 0 14 27 19 time 14 27 20 0 14 27 20 1 14 AXB 232 Program Statements 15 Xmodem Timing Commands 15 AxLink Master Statements 15 Reserved Cha...

Страница 5: ...9600 19200 and 38400 56400 is supported via the BAUDMED Send Command see the Send_Commands section on page 12 for details 115200 is supported via the BAUDHIGH Send Command see the Send_Commands sectio...

Страница 6: ...ector Receives power and data via the AxLink bus and AxLink system controller 4 pin male Internal Jumpers Sets differential input termination and enables RS 485 output Supports XON XOFF software and h...

Страница 7: ...oss RS422 receive data pins 5 6 1 Disconnect the RS 232 422 485 connectors 2 Unscrew the two screws on the rear panel and remove the panel 3 Slide the circuit board out of the enclosure 4 Locate the J...

Страница 8: ...front panel see FIG 1 on page 5 The AXB 232 supports the following asynchronous data standards The table below shows the RS 232 422 DIP switch numbers functions and their corresponding values DEVICE D...

Страница 9: ...umption supplied voltage and the wire gauge used for the cable The table below lists wire sizes and maximum lengths allowable between the AXB RS232 and Central Controller The maximum wiring lengths fo...

Страница 10: ...6 Using RS 422 When communicating via RS 422 connect the wiring as shown in FIG 7 Using RS 485 When communicating via RS 485 connect the wiring as shown in FIG 8 FIG 6 Hardware handshaking wiring FIG...

Страница 11: ...ou replace the batteries incorrectly Replace batteries with the same or equivalent type recommended by the manufacturer Dispose of the used batteries according to the manufacturer s instructions Never...

Страница 12: ...Enables 300 baud rate when the DIP switch is set to 300 baud setting default Syntax BAUDLOW Example SEND_COMMAND AXB232 BAUDLOW BAUDMED Enables 57 600 baud rate when the DIP switch is set to 300 baud...

Страница 13: ...eceive buffer waiting to be sent to the Master If RXCLR is sent while RTS is low RTS returns high Syntax RXCLR Example SEND_COMMAND AXB232 RXCLR RXOFF AXB 232 does not pass on received characters to t...

Страница 14: ...k character of 1mS 27 18 1 Sets the ninth data bit to 1 for all of the following characters to be transmitted Syntax 27 18 1 Example SEND_STRING AXB232 27 18 1 Used in conjunction with the B9MON comma...

Страница 15: ...ster Sends a message that channel is off OFF 1 channel Turns off a channel This command has no external effect It can be used as status ON 0 channel Sends a PUSH to the Master Sends a message that cha...

Страница 16: ...EVEL AXB_232 level variable Places the variable into the CREATE_LEVEL variable if it were defined in the AXB 232 DEFINE_START section SEND_STRING AXB_232 string Places the string into the CREATE_BUFFE...

Страница 17: ...assume responsibility for errors or omissions AMX also reserves the right to alter specifications without prior notice at any time The AMX Warranty and Return Policy and related documents can be view...