C. Loss of Power

Minimizing Smoke During Loss of Power Using Battery 

Back-up
Harman® strongly recommends installing battery back-

up to minimize entry of smoke into the room in the 

event of power loss.

Your  pellet/biomass  burning  appliance  relies  on  a 

combustion blower to remove exhaust. A power failure will 

cause the combustion blower to stop. This may lead to 

exhaust seeping into the room. Vertical rise in the venting 

may provide natural draft. It is, however, no guarantee 

against leakage.

There are two Harman® approved battery back-up 

options for your appliance:
Uninterruptible Power Supply (UPS)

  battery  back-ups 

are  available  online  or  at  computer  and  office  equipment 

stores. Your Harman® appliance may be plugged directly 

into a Harman® approved UPS:

•  The  APC  (American  Power  Conversion)  model 

#BE750G and the TrippLite model INTERNET750U are 

tested and approved. Other brands or models may not 

be compatible.

When power is lost, a fully charged UPS will power a safe, 

combustion  blower  only  shut-down.  Your  appliance  will 

pulse the blower every few seconds to clear exhaust until 

the fire is out.

 NOTE: The UPS provides safe shut-down 

only. It is not intended for continued operation.

•  The Surefire 512 connects to a 12 volt deep cycle battery 

that will run your appliance for up to eight (8) hours. It 

includes a trickle charge feature that keeps your battery 

charged when power is available. NOTE: If the power is 

out for longer than battery life, smoke leakage may still 

occur unless your stove has been safely shut down.

Your appliance will recognize when power is restored. What 

happens depends on ESP temperature and whether it is 

equipped with automatic ignition:

 

In “Automatic” Mode

, units will respond to the set point 

and ESP temperature and resume normal operation.

• 

In “Idle” Mode

, or for units without automatic ignition:

•  If the ESP is cool, the appliance will remain shut 

down.

•  If the fire is out and the ESP is still warm, the feeder 

may restart. Since the fire is out, the ESP temperature 

will not rise. The unit will then shut-down, and may 

flash a six-blink status error. (See ESP error codes)

•  If  the  fire  is  still  burning,  it  will  resume  normal 

operation.

Contact your dealer if you have questions about UPS 

compatibility with your appliance.

Use only Harman

®

 approved battery back-up devices. 

Other products may not operate properly, can create 

unsafe conditions or damage your appliance.

CAUTION

!

Always keep appliance doors and hopper lid closed 

and latched during operation and during power 

failures to minimize risk of smoke or burn-back.

D. Emergency Manual Ignition

Harman

®

 pellet stoves and inserts should be lit using the 

automatic ignition system. This is the safest and most 

reliable way for igniting the unit.  In the event the automatic 

igniter is not functioning, the steps below may be followed 

to manually light the stove or insert in the “Constant Burn” 

mode. Manual lighting is for emergency purposes only, 

and the igniter should be repaired or replaced as soon as 

practical.

WARNING

!

Only  use  firestarter  commercially  marketed  for  pellet 

stoves  and  inserts,  including  wax  coated  wood  chips, 

pellet starter gel and pellet igniter blocks. Use of any 

other type of firestarter is prohibited.

To  avoid  serious  injury  or  death  read  and  follow 

manufacturer’s warning and instructions for use of firestarter. 

Use of firestarter is only permitted when performing a cold 

start.
Never attempt to manually light a stove or insert that has 

been operated recently and is not at room temperature. 

If automatic ignition was attempted, be sure to give the 

stove or insert at least 30 minutes or longer to cool to room 

temperature.

Be sure that the stove or insert is in the “Igniter - Disabled” 

mode of operation.

Once  all  the  precautions  have  been  taken,  follow  these 

steps:

1.  On  the  touch  control,  select  the  Burn  Mode  icon  then 

select “Constant Burn”.

2.   Arrow back and select the Igniter icon then select “Manual” 

for the ignition method. Select the Home Icon to go back 

to the Main Menu.

3.  Fill burn pot with pellets, only half way. (Do Not Over Fill).

4.  Add firestarter to pellets following manufacturer’s 

instructions.

5.  Light pellet firestarter with a match, and close the door, 

touch the On/Off icon on the home screen. Operation will 

begin when the fire reaches the proper temperature.

WARNING

!

Содержание Absolute63

Страница 1: ...m as stove Alertchildrenandadultstohazardsofhightemperatures High temperatures may ignite clothing or other flammable materials Keep clothing furniture draperies and other flammable materials away HOT SURFACES Glass and other surfaces are hot during operation AND cool down WARNING Please read this entire manual before installation and use of this pellet fuel burning room heater Failure to follow t...

Страница 2: ...e sol non combustible sous l appereil qui s étend sur les côtes l avant et l arrière du poêle voir schéma Pour la distance à l avant mesurer à partir de la surface de la porte en verre ll est recommendé que la protection s étende jusque sous le conduit en cas d installation d un conduit horizontal ou sous le té en cas conduit vertical Do not remove this label Ne pas enlever cette étiquette Made in...

Страница 3: ... Parts 16 B Limited Lifetime Warranty 21 C Loss of Power Addendum 24 D Emergency Manual Ignition 24 E Troubleshooting 25 F Contact Information 26 1 Product Specifications and Important Safety Information A Appliance Certification Specifications 4 B Mobile Home Approval 4 C BTU Efficiency Specifications 4 D Appliance Safety 5 E Clear Space 5 F Helpful Hints 6 G Fuel Specifications 6 H Quick Start G...

Страница 4: ...n the maximum feed rate per hour multiplied by approximately 8600 BTU s which is the average BTU s from a pound of pellets This wood heater has a manufacturer set minimum low burn rate that must not be altered It is against federal regulations to alter this setting or otherwise operate this wood heater in a manner inconsistent with operating instructions in this manual This wood heater needs perio...

Страница 5: ...e present Use only specified components as replacement parts Other components may not allow your stove to operate as it was intended Contact your dealer for more information or visit www hpba org safety information To prevent unintended operation when not using your stove for an extended period of time summer months vacations trips etc Unplug stove from receptacle Due to high temperatures this sto...

Страница 6: ...te the residence Before using the appliance have the venting system thoroughly inspected and replace any damaged components With any hearth appliance installation of smoke detectors is recommended on every level of the home Possible causes of smoke detector activation Paint curing process Open a window near the appliance for the first few hours of burning Exhaust being drawn back inside the dwelli...

Страница 7: ...y other fuel will void your warranty G Fuel Specifications Cont Storage Wood pellets should be left in their original sealed bag until ready to use to prevent moisture Do not store fuel within the specified clearance areas or in a location that will interfere with routine cleaning and maintenance procedures BURNING COLORED PAPER CARDBOARD SOLVENTS TRASH AND GARBAGE OR ALTERING THE STOVE FOR HIGHER...

Страница 8: ...16 ___ 11 17 8 3 90 999000c H Quick Start Guide 2 Fill hopper with pellets 3 Adjust arrows to set room desired temperature 4 Touch the On Off Power Icon Refer to Touch Manual for all other operations Initial start up Only 1 Select Language ...

Страница 9: ...arge flame at start up This is normal Flame will settle down once the fire is established Missed Ignition Ensure there are pellets in burnpot Ensure holes in burnpot are clear of obstructions above the igniter See Burnpot Maintenance Check to see if the ignitor is getting hot if not replace ignitor See manual ignition instructions for emergency heating needs I Frequently Asked Questions With prope...

Страница 10: ... will disappear in 30 seconds Replace the 2 AA batteries in the Wireless Remote Sensor If Wireless Remote Sensor batteries die the Back Up Sensor will continue to heat your home Check and close the front and ash doors for the stove to continue to heat Close the hopper lid for the stove to continue to heat Fill the hopper with pellets Press check mark to reset If you did not fill the hopper the mes...

Страница 11: ...E THE STOVE MUSTBE COMPLETELYOUTBEFORE YOU VACUUM THE STOVE LIVE PELLET EMBERS IF SUCKED INTO THE VACUUM WILL LIGHT THE VACUUM ON FIRE AND MAY ULTIMATELY CAUSE A HOUSE FIRE Follow the detailed instructions found in this section for each step listed in the chart below Shock and Smoke Hazard Turn unit to the off position let appliance completely cool and combustion fan must be off Now you can unplug...

Страница 12: ...t ashes into a steel non combustible container with tight fitting lid outside Use provided paint brush Vacuum loose ash from around igniter and inside burn pot Stove MUST be turned off cold and unplugged from power supply for Yearly Cleaning Yearly4 Brush vacuum the combustion fan and venting exhaust path Wear protective gloves 1 Put ashes into a steel non combustible container with tight fitting ...

Страница 13: ... Cleaning Glass Once unit is cold use a non abrasive glass cleaner on glass and wipe clean Scrape and Vacuum Heat Exchanger Cleaning the Heat Exchanger Clean the heat exchanger with scraper as shown in Figure 2 2 Brush or scrape the inside of the stove to remove fly ash Remove the ash pan and dispose of ashes in an approved manner according to local codes Cleaning the Burn Pot Vigorously scrape th...

Страница 14: ...re 2 6 Note The hot lead cold lead connection must always be pulled to the rear of the feeder body before operation Use caution when cleaning burn pot clean out chamber Do not damage the high temperature igniter wires WARNING Clean Ash Accumulation Figure 2 6 Yearly Maintenance Cleaning the Combustion Fan Chamber The combustion inlet cover is located behind the ash pan that must be removed to prop...

Страница 15: ...tances Wash the surface with cool water and rinse thoroughly You may wish to use a non abrasive cleaner specifically designed for use on stove glass In any case dry thoroughly before relighting your stove Inspect all Gaskets While the unit is cool inspect all door gaskets to insure proper seal The gasket should be continuous without frays or tears having plyable gasket means having a correct seal ...

Страница 16: ...nce Material Service Parts Absolute63 Beginning Manufacturing Date Dec 2016 Ending Manufacturing Date Active Part number list on following page Pellet Stove 11 17 1 90 999000 1 Matte Black 1 90 999000 14 Majolica Brown 1 3 4 2 5 6 7 8 9 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 10 ...

Страница 17: ...ete Latch 1 00 0669697 5 16 X 1 2 Ball Plunger Pkg of 3 3 31 5500 3 Bulk 5 16 Push Retainer Pkg of 100 3 31 94807 100 Hopper Lid Hinge w Hardware 1 00 777771 Y Hopper Lid Hinge Pin Plates w Hardware 1 Set 1 00 777560 4 Cast Top Black 4 00 999132S Majolica Brown 1 00 999132 14 5 Hopper Assembly 1 10 999157A Y Gasket Hopper Throat 3 44 677185 Y Gasket 3 8 X 1 2 20 Feet 1 00 375501 Y 6 Left Side Cast...

Страница 18: ...1 4 Gasket 3 16 RD Blk LD W PSA 10 Feet 1 00 1186258229 Y 11 5 Glass w Gasket 1 00 999146 Y 11 6 Glass Clips w Hardware 1 Set 1 00 999145 Y 11 7 Load Door Hinge w Hardware 1 Set 1 00 999114 Y 11 8 Gasket 3 8 4 Strand 30 Feet 1 00 00888 Y 12 Ashlip Black 3 00 999129P Majolica Brown 1 00 999129 14 13 Ash Door Handle Assembly 1 Set 1 00 777149 Y Rollers Hardware 1 Set 1 00 77723 Y 14 Ash Door Complet...

Страница 19: ...st 3 00 247237 Y 25 Rear Cover Right 1 00 999125 Y 26 Rear Cover Left 1 00 999126 Y 27 Feeder Assembly 27 1 Feeder Body 1 10 680021W Y 27 3 Slide Plate Assembly 1 10 677121A Y 27 3 Feed Cover Gasket 2 Sets 1 00 677122 Y 27 4 Pusher Arm 1 10 677131W Y Pillow Block Pkg of 4 3 31 3614087 4 Y 27 5 Auger 3 50 00565 Y Gasket Auger Pkg of 5 1 00 888196 27 6 Bearing Retainer w Hardware 1 00 04035 Y Cam Be...

Страница 20: ...pot ITEM DESCRIPTION COMMENTS PART NUMBER 5A Ceramic Fuse Pkg of 5 1 00 05237 Y Burn Pot Scraper Pkg of 10 2 00 777692 10 Communication Cable 3 20 72662 Y Differential Switch 3 20 6866 Y Draft Meter Assembly 1 00 00637 Draft Meter Bolt Tube 1 00 04004 ESP Probe Red Red 3 20 00844 Y External Temp Extension 3 20 70607 Y Flue Tube Cleaning Brush 3 40 00126 Bottom Heat Shield 1 00 999144 Y Control Boa...

Страница 21: ... or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier However the warranty shall commence no later than 24 months following the date of product shipment from HHT regardless of the installation or occupancy date The warranty period for parts and labor for covered components is produced in the following table The term Limited Lifeti...

Страница 22: ...ome changes in color of interior and exterior surface finishes may occur This is not a flaw and is not covered under warranty Damage to printed plated or enameled surfaces caused by fingerprints accidents misuse scratches melted items or other external sources and residues left on the plated surfaces from the use of abrasive cleaners or polishes Repair or replacement of parts that are subject to n...

Страница 23: ...ot limited to improper chimney or venting installation LIMITATIONS OF LIABILITY The owner s exclusive remedy and HHT s sole obligation under this warranty under any other warranty express or implied or in contract tort or otherwise shall be limited to replacement repair or refund as specified above In no event will HHT be liable for any incidental or consequential damages caused by defects in the ...

Страница 24: ... The unit will then shut down and may flash a six blink status error See ESP error codes If the fire is still burning it will resume normal operation Contact your dealer if you have questions about UPS compatibility with your appliance Use only Harman approved battery back up devices Other products may not operate properly can create unsafe conditions or damage your appliance CAUTION Always keep a...

Страница 25: ... Smoke smell Seal the vent pipe joints and connection to stove with silicone The exhaust vent is the only part of the system that is under positive pressure Fire has gone out No fuel in hopper Draft is too low blocked flue Something is restricting fuel flow Hopper lid not closed properly Feed motor or combustion fan has failed Smoke is visible coming out of vent Air fuel ratio is too rich Feed rat...

Страница 26: ...____ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ _______________________________________________________________________...

Отзывы: