Harman®  •  300i Wood Insert Owner’s Manual_R13  •  2010 -___  •  04/15

Congratulations

, The Harman

®

 300i Woodburning Fireplace 

Insert you have selected is designed to provide the utmost 

in safety, reliability, and efficiency.

As the owner of a new Wood Insert, you’ll want to read and 

carefully follow all of the instructions contained in this owner’s 

manual. Pay special attention to all cautions and warnings.

This owner’s manual

 

should be retained for future reference. 

We suggest that you keep it with your other important 

documents and product manuals.
Your new Harman

®

 300i Woodburning Fireplace Insert will 

give you years of durable use and trouble-free enjoyment. 

Welcome to the Harman

®

 family!

read this manual before operating this appliance. 

please retain this owner’s Manual for future reference.

read the Installation Manual before making any installation or finishing changes.

listing label Information/location

The model information regarding your specific stove can be found on the 

rating plate usually located in the control area of the stove.

The Safety/ Certification label is attached by a chain under the ash 

lip. The label includes the appliance serial number and important 

safety information. Record the number here for future reference. 

Serial #:

 

008_______________________

purchase date: _____________________

A

B

C

D

300i Woodburning Fireplace Insert

Poêle Du Bois 300i

Date of Manufacture / Date de fabrication:

2014  2015  2016  JAN   FEB   MAR   APR   MAY   JUN   JUL   AUG   SEP   OCT   NOV   DEC

Made in U.S.A. of US and imported parts. / Fabriqué aux États-Unis-d’Amérique par des pièces d’origine américaine et pièces importées.

Floor Protector / Protecteur de plancher

8” / 200 mm

 18”

 / 450 mm

8” / 200 mm

P.N. 3-90-300100

MINIMUM CLEARANCE TO COMBUSTIBLE MATERIAL 

ECARTS MINIMUM DE SÉCURITÉ

Non-combustible floor protector / La protection de sol doit être 

constituée de matériau incombustible

Floor Protection must be a minimum R= 2.02

See Manufacturer’s instructions for additional floor protection guidelines.

BARCODE LABEL

008

Serial No.

N

o

 de série:

DO NOT REMOVE THIS LABEL / Ne pas enlever cette étiquette

U.S. ENVIRONMENTAL PROTECTION AGENCY

Certified to comply with July 1990 particulate emission standards.

Date of Manufacture/Date de fabrication:

Rev C

CAUTION:

 

HOT  WHILE  IN  OPERATION. DO  NOT  TOUCH. 

KEEP CHILDREN AND CLOTHING AWAY. CONTACT MAY CAUSE SKIN 

BURNS. SEE NAMEPLATE AND INSTRUCTIONS. KEEP FURNISHINGS 

AND OTHER COMBUSTIBLE MATERIALS A CONSIDERABLE DISTANCE 

AWAY FROM THIS APPLIANCE.

ATTENTION:

 

CHAUD LORS DU FONCTIONNEMENT. NE 

TOUCHEZ PAS L’APPAREIL.GARDEZ LES ENFANTS ET LES VÊTEMENTS ÉLOIGNÉS. 

TOUT CONTACT PEUT ENTRAÎNER DES BRÛLURES DE LA PEAU.  RÉFÉREZ-VOUS À 

LA PLAQUE SIGNALÉTIQUE ET AU MODE D’EMPLOI. GARDEZ LE MOBILIER ET LES 

AUTRES MATÉRIAUX COMBUSTIBLES BIEN À L’ÉCART DE L’APPAREIL.

Not Approved For Use in Mobile/Manufactured Homes

This appliance is also approved for installation into a shop.

“PREVENT HOUSE FIRES”

Install and use only in accordance with manufacturer’s installation and operation instructions 

and local codes. In absence of local codes, installation must meet minimum requirements 

of NFPA 211 in USA. Refer to manufacturer’s instructions and local codes for precautions 

required for passing chimney through a combustible wall or ceiling. 

Flue connector pipe must be 6” diameter, minimum 24 MSG blue steel. Chimney must be 

factory built 103HT or masonry construction with a tile liner.

Contact Local Building or Fire Officials About Restrictions and Installation Inspection 

In Your Area.

DO  NOT  CONNECT  THIS  APPLIANCE  TO  A  CHIMNEY  FLUE  SERVING  ANOTHER 

APPLIANCE.

FOR USE wITH SOlId wOOd FUEl ONly d

o not burn coal.

DO NOT Overfire - If Heater or chimney connector glows, you are overfiring.

Blowers: Electrical Rating 115 VAC, 60Hz, 1AMP Maximum 

Route power cord away from unit. 

Replace glass only with 5mm ceramic, available from your dealer.

Do not obstruct airflow under the appliance.

DANGER: Risk of Fire or Explosion - Do not burn garbage,  gasoline, drain oil or other 

flammable liquids.

WARNING! RISk OF FLAME OR SMOkE SPILLAGE: Fuel loading door must be fully 

open or fully closed during operation. 

Do not store fuel or combustibles within marked clearances. Inspect and clean chimney 

and connector regularly Under certain conditions of use, creosote buildup may occur 

rapidly. The Bypass Damper must be opened prior to opening the load door.

Do not install a grate or otherwise elevate the fire.

Pas approuvé pour utilisation dans le mobile / Manufactured Homes

Cet appareil est également homologué pour être installé dans un atelier.
«ÉVITEZ LES INCENDIES DE MAISON»

N’installez et n’utilisez cet appareil que selon le mode d’installation et le mode d’emploi du 

fabricant et les codes locaux. En l’absence de codes locaux, l’installation doit au minimum être 

conforme aux exigences de la norme NFPA 211 aux É.-U. Voir dans les recommandations du 

fabricant et dans les codes locaux les précautions quant au passage d’une cheminée à travers 

un mur ou un plafond combustible.

Le tuyau de raccord à la cheminée doit être d’un diamètre de 15,25 cm (6 po), au minimum 

en acier bleu 24 MSG. La cheminée doit être en métal 103HT d’usine ou construite en 

maçonnerie.

NE RELIEZ PAS CE POÊLE À UNE CHEMINÉE QUI SERT POUR UN AUTRE APPAREIL.

IL NE FAUT UTILISER QUE DU BOIS EN BUCHES. Ne chauffez pas TROP. Si l’appareil ou 

le raccord de cheminée rougit, c’est que le feu est trop puissant. Éloignez le cordon électrique 

de l’appareil.

DANGER: Risque de décharge électrique. Débranchez la prise avant tout entretien. Pour plus 

de détails, consultez le mode d’emploi.

Ne remplacez le verre que par du verre céramique de 5 mm à obtenir de votre détaillant.

L’appareil doit être installé avec ses pieds fixés. N’obstruez pas le passage d’air sous l’appareil.

DANGER: Risque d’incendie ou d’explosion. Ne brûlez pas d’ordures, d’essence, d’huile de 

vidange ni aucun autre liquide inflammable.

MISE EN GARDE:

 

Risque de la flamme ou fumée déversement, le combustible chargement 

porte doit être complètement ouverts ou fermés pour l’opération.

Gardez le carburant et les matériaux combustibles en dehors des dégagements prescrits.

Inspectez et nettoyez fréquemment les conduits et la cheminée.

Tests réalisés par OMNI-Test Laboratories, Inc.

Report #/Rapport #135-S-18-6, #135-S-18b-6.2

Tested to/Testé selon: July 2010, UL 1482-2010, UL 737-2007, 

and ULC-S628-93

Certified for U.S.A. and Canada/Certifié pour les 

é

tats-Unis 

et le Canada

C
D

B

A

Location

Inches Millimeters

Insert to combustible sidwall
Insert side to face trime
Insert top to (max) 12” Mantel
Insert top to face trim

29.6
13.6

30
20

762
345
762
508

Window opening to front
Window opening to side

Location

Inches Millimeters

18

8

450
200

Manufactured by/Fabriqué par: Hearth and Home Technologies

10.5”

6.75”

Model Name

Serial Number

Содержание 300i

Страница 1: ...adults to hazards of high temperatures High temperatures may ignite clothing or other flammable materials Keep clothing furniture draperies and other flammable materials away HOT SURFACES Glass and other surfaces are hot during operation AND cool down WARNING Please read this entire manual before installation and use of this wood burning room heater Failure to follow these instructions could resul...

Страница 2: ...ll or ceiling Flue connector pipe must be 6 diameter minimum 24 MSG blue steel Chimney must be factory built 103HT or masonry construction with a tile liner Contact Local Building or Fire Officials About Restrictions and Installation Inspection In Your Area DO NOT CONNECT THIS APPLIANCE TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE FOR USE wITH SOlId wOOd FUEl ONly do not burn coal DO NOT Overfire I...

Страница 3: ... Curing 14 The Combustion Process 14 15 Damper Bypass Operation 15 Air Control Operation 15 16 Overfiring 16 Building Maintaining a Fire 17 Operations as a Fireplace 17 Blower Operation 17 Table of Contents Safety Alert Key DANGER Indicates a hazardous situation which if not avoided will result in death or serious injury WARNING Indicates a hazardous situation which if not avoided could result in ...

Страница 4: ...ons 1 1 g hr EPA Default Efficiency 63 Actual Tested Efficiency 77 EPA BTU Output 34 900 BTU Input 72 100 Vent Size 6 Inch Recommend Log Lenght 20 Maximum Fuel Seasoned Cord Wood An efficiency based on EPA historical data of 78 Actual tested efficiency and data collected during EPA emissions test A range of BTU outputs based on EPA default efficiency and the burn rates from the low and high EPA te...

Страница 5: ...CE IF THIS APPLIANCE IS NOT PROPERLY INSTALLED OPERATED AND MAINTAINED A HOUSE FIRE MAY RESULT FOR YOUR SAFETY FOLLOW INSTALLATION DIRECTIONS CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA Fire Safety Maintain the designated clearances to combustibles Insulation must not touch the chimney You must maintain the designated air space ...

Страница 6: ... Flue pipe adapter Bypass Damper Control Door Latch Andirons Surround Top Surround Side Component Locations Appliance Dimension Diagram Dimensions are actual appliance dimensions Use for reference only 41 1042mm 40 1016mm 28 711mm 17 5 8 447mm 30 762mm 23 3 4 603mm 12 1 2 318mm 17 5 8 447mm 12 1 2 318mm 28 1 2 724mm 5 1 8 129mm ...

Страница 7: ...8 200mm 18 457mm Top View 8 200mm Floor protection in front of the raised hearth must be a minimum 3 8 9 5mm of 0 84k material An R value of 0 45 or higher is also acceptable The standards call for floor protection to extend a minimum of 18 457mm in front of the appliance door opening and 8 200mm to each side No additional floor protection required Floor Protection requirements Raised Hearth 6 152...

Страница 8: ...lue damper must be removed or locked in the open position Masonry Direct Connect Installation This method is less expensive than a full re line However you ll need to check with your local codes to be sure that this is an acceptable installation method as most municipalities require a full liner Hearth Home Technologies also recommends the installation of a full liner The connector pipe must be ma...

Страница 9: ... attempting any clearance reduction From the front of the insert the clearance to combustible materials such as furniture curtains or fuel is 48 1215mm in the U S and 60 1525mm in Canada The clearance from the top of the insert to a 12 305mm mantel is 30 762mm and to facing trim 1 1 2 38mm thick is 20 508mm The clearance from the side of the insert to facing trim 1 1 2 38mm thick is 13 5 8 345mm a...

Страница 10: ...ont of the fireplace opening Keep the height of the bracket at approximately 24 from the floor While sliding the insert into the fireplace guide the flue collar bracket onto the top of the insert The bracket will pull itself into position as the stove body comes back The bend on the front of the flue bracket and the hooks on the rear will secure the flue collar tightly to the insert When the flue ...

Страница 11: ...front To engage the front roller for movement you ll first need to remove the lower base cover As shown above the cover is installed with a screw at each end of it Remove these screws using a 5 16 socket or driver Slide the cover toward the front and set aside To engage the roller begin by lifting the roller up and forward in its brackets This will get the roller in its ready position Lift the fro...

Страница 12: ...de that you want the power cord remove the knockout from the surround panel and insert the power cord connectors through it Pull the insulated wire connections from the blower motor and in their place hook up the two female connectors from the cord Next attach the two male connectors from the cord to the insulated wire ends that were removed from the blower Plug the green wire from the power cord ...

Страница 13: ...installing the support brackets on each end of the top panel as shown Notice the bottom hole is the one that is threaded Next install the top panel by inserting the four 4 studs through the holes in the fin on the insert Secure with the provided nuts and a 11 32 nut driver Install the side panels as shown below using two button head screws at the top and one self tapping Tek screw at the bottom Th...

Страница 14: ...e glass by slamming the door shut or striking the glass with a heavy object Do not clean the glass while it is hot If the glass is broken or damaged do not operate the insert until it has been replaced See instructions in the Maintenance section CAUTION Hot while in operation keep children clothing and furniture away Contact may cause skin burns Andirons The andirons keep the fuel from coming in d...

Страница 15: ...om In this mode of operation the combustion gases go directly from the main combustion chamber to the flue collar and exit into the chimney Lift upward on the damper handle to open the bypass damper and push down to close it NOTE The bypass damper must be open for smokeless loading Air Control Shown In The Medium High Position Air Control Shown In The Medium Low Position Air Control The air contro...

Страница 16: ...zed fuel to retain the fire Close the door before taking the ashes outside for safe disposal Medium High Burn Rate air control set between the second and third notch This setting may be used to burn wood that is damp in order to keep it burning but will consume seasoned dry wood very fast High Burn Rate air control fully to the right This setting is for refueling and starting a fire Continuous bur...

Страница 17: ...ed by a few 2 3 50mm 80mm split pieces Lay the wood in a crossed pattern to allow maximum air flow Ignite the paper and close the loading door Allow this start up fire to burn for a few minutes keeping the bypass damper open Add about five more pieces of wood in the 2 3 50mm 80mm size range making sure that the fuel bed is all the way across the firebox and staggered to allow airflow Close the doo...

Страница 18: ... not use substitutes To replace the glass panel you will need to remove the door To do this open the door lift it straight up and place it face down on a flat surface Carefully remove damaged glass gasket material and hold down clips set aside Referring to the diagram note how the various components of the door system fit together Lay the load door face down on the flat surface Install the self ad...

Страница 19: ...cracks or damage should be repaired before further use of the insert Occasionally it will be necessary to remove the insert to inspect the appliance and the fireplace To remove the insert you will first need to remove the two bolts that secure the flue adapter to the top of the insert Slide the insert out of the fireplace for inspection Have any cracks or damage repaired before further use of the ...

Страница 20: ...0 ___ 04 15 Service Parts 300i Beginning Manufacturing Date Sept 2010 Ending Manufacturing Date Active Part number list on following page Wood Insert 1 70 300100 1 Black Ending Manufacturing Date June 2011 1 70 300100 2 Charcoal 1 70 300100 3 Golden re 1 2 3 4 5 6 7 8 9 10 12 23 27 22 14 17 16 18 19 21 24 26 25 20 13 11 15 4 15 ...

Страница 21: ...249107 Damper Shaft Retainers Hardware 1 00 249145 Y Adjuster w Hardware Pre 008700287 1 00 249142 Y Post 008700287 1 00 250153 4 Damper Linkage 1 10 249146 Y 5 Damper Shaft Cover 1 10 06918W 6 Flue Plate 1 10 300122W Y 7 Linkage Kit 1 00 300101 Y 8 Damper Arm Cover 2 00 300121P 9 Left Rear Side 2 00 300104B 10 Left Blower Bracket 2 00 300106 1B Screw HWH TEKS 10 X 3 4 Pkg of 100 3 30 5004 100 Y 1...

Страница 22: ...6714 Cast Door Painted 4 00 06920P Glass with Gasket 1 00 06932 Y Glass Clips Pkg of 4 2 00 05202 4 Y Latch Adjuster 2 00 06713D Gasket Glass 1 4 Round Black PSA 15 Ft 1 00 2312 Y Gasket Door 3 8 4 Strand White 30 Ft 1 00 00888 Y 20 Wooden Handle w Bolt 2 Sets 1 00 00247 Y Door Handle Assembly 1 00 249119 Y 21 1 SS Brick Clip Set Set of 2 1 00 249153 Y 21 2 Left Plate Assembly w Gasket 1 10 249117...

Страница 23: ...Y Screw HWH TEKS 10 X 3 4 Pkg of 100 3 30 5004 100 Y 23 Power Cord w VSC 3 20 300140 Y 24 Right Blower Bracket 2 00 300106 2B Screw HWH TEKS 10 X 3 4 Pkg of 100 3 30 5004 100 Y 25 Right Rear Side 2 00 300105B 26 Blower Right Side 3 21 32080 Y 27 Combustion Package with Gaskets 3 40 06999 Y Package Cover 2 00 06996B Y Gasket Brick Air Pkg of 4 3 44 2500202 4 Y Gacket Set Complete 3 44 06999 Y Ball ...

Страница 24: ...egins on the date of original purchase In the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier The warranty shall commence no later than 24 months following the date of product shipment from HHT regardless of the installation ...

Страница 25: ...THE EXPRESSED WARRANTY SPECIFIED ABOVE warranty eXclUsIons This warranty does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw and is not covered under warranty Damage to printed plated or enameled surfaces caused by fingerprints accidents misuse scratche...

Страница 26: ...________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ___________________________________...

Отзывы: