Harman TL300 7

The Stove

Doors

Your stove has a large glass-paneled door for loading and 

fire viewing, a separate smaller door for removing ashes, and 

a top loading door.  

Front Door

Before opening, always check for wood, embers, or ash 

that may be ready to fall out of the door. 

To open the glass door, open bypass damper first, by pulling 

forward on the top load door handle, to the first position. Then 

lift up on the front door handle to disengage the latch, and pull 

out. To close the door, push door closed with handle in the 

open position, then push handle down to engage the latch.  

Ash Door

To open the ash door, open the bypass damper first. Lift up 

on the ash door handle and pull it open. Close the door by 

pushing in and pushing the handle all the way down. 

Top Load Door

To open the top load door, pull forward on the top load 

door handle. The first position tells you the bypass damper is 

open. Continue pivoting the handle toward you until it locks 

the top load door open.

All  doors  must  be  closed  while  the  stove  is  in  normal 

operation, and the gaskets routinely examined for wear and 

replaced when necessary.  Good door seals are important for 

maintaining control of the stove.  Never operate with the ash 

door open. Operating the stove with the ash door open, or with 

a door improperly sealed, could create a serious overfiring 

condition (discussed later in this section).

General Considerations

Draft

Before you install and/or operate your TL300 wood stove, 

please read the entire contents of this manual. Pay particular 

attention to the explanation of draft and its effect on stove 

performance, in the installation section. By following the 

installation and operating guidelines, you will ensure proper 

draft and gain maximum efficiency and enjoyment from 

your stove.

Fuel

Your TL300  burns wood very efficiently.  Here are some 

guidelines concerning log size and moisture content that will 

help you obtain the best performance.

Select  dry  seasoned  wood.  For  example,  it  should  be 

checked or cracked on the ends and not exposed to rain or 

extremely damp conditions. Hardwoods are favored because 

they are heavier and contain more heating capacity (BTU’s) 

per load than do softwoods.  Wood should be split and stored 

under cover for “seasoning” - a year is recommended.  Your 

stove is not an incinerator - do not burn garbage, painted or 

treated wood, plastics, or other debris.

Keep the area around the stove free from clutter.  Keep 

all combustibles, including fuel, beyond the code-required 

clearance distance (48" or 1215 mm in the U.S., 1525 mm 

or 60" in Canada).  Never store fuel in front of the stove 

where it could interfere with door operation, safe loading, 

and ash removal.

Do not burn garbage or flammable fluids such 

as gasoline, naptha, or engine oil.

Specifications

NEVER OPERATE WITH MORE THAN 

ONE DOOR OPEN AT A TIME.

The glass used in your TL300 is manufactured to exact 

standards to withstand the high heat of the fire, but like all 

glass, it must be treated with common sense and care.  Never 

abuse the  glass by slamming the door shut or striking the glass 

with a heavy object.  If the glass is broken or damaged, do not 

operate the stove until it has been replaced (See instructions 

in Maintenance section.)

Grates 

The Harman TL300 has a unique grate system that consists 

of one bottom grate, and two front andirons.  The bottom grate 

has slots which allow the ash to fall into the ash pan by passing 

a poker back and forth across the grate. The andirons keep 

the fuel from coming into direct contact with the glass, and 

keep hot coals and embers from spilling out while reloading. 

Never build a fire directly against the glass. Andiron exten-

sions (included with each stove) clip onto the fixed andirons 

and serve to protect the glass when top loading is used as 

the primary loading method. The grates and andirons must 

remain in place at all times. Do not tamper with or change 

the configuration of this grate system.

CAUTION: 

Always wear fire retardant gloves 

when operating the stove.

SAFETY NOTICE

IF THIS HARMAN TL300 STOVE IS NOT 

PROPERLY  INSTALLED,  OPERATED 

AND MAINTAINED, A HOUSE FIRE MAY 

RESULT.  FOR YOUR  SAFETY,  FOLLOW  

INSTALLATION  DIRECTIONS.  CONTACT 

LOCAL  BUILDING  OR  FIRE  OFFICIALS 

ABOUT RESTRICTIONS AND INSTALLA-

TION  INSPECTION  REQUIREMENTS  IN 

YOUR AREA.

Содержание TL300

Страница 1: ...ble for installation in a mobile home us only IF THIS wood burning STOVE IS NOT PROPERLY INSTALLED A HOUSE FIRE MAY RESULT FOR YOUR SAFETY FOLLOW INSTALLATION DIRECTIONS CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA Contact your local authority such as municipal building department fire department fire prevention bureau etc to det...

Страница 2: ...2 Harman TL300 ...

Страница 3: ...re to follow instructions may result in property damage bodily injury or even death Index Hearth Home Technologies Inc 352 Mountain House Road Halifax PA 17032 U S A Introduction 4 Specifications 5 Installation 8 Venting 10 Operation Building a Fire 16 Maintenance 19 Options 21 Service Parts 22 Warranty 26 ...

Страница 4: ...EUblES oUAUtrES obJEStAriSqUE Listed soLid FueL FirepLace stove or room Heater appareiL de cHauFFage ou poeLe a combustibLe soLide Model Modele Tl300 Serial NuMber NuMero de Serie CLEARANCE TO COMBUSTIBLE SURFACES A Unit to Sidewall B Unit to Backwall C Chimney Connector to Sidewall D Chimney Connector to Backwall E Unit to Adjacent Wall F Chimney Connector to Adjacent Wall See manual for addition...

Страница 5: ...issions Emissons on Low Outside Air Size 525 Lbs 6 inch 18 in 20 in Max 1 500 3000 sq ft 1 1 Grams Per Hr 0 8 Grams Per Hr 3 or 4 inch SAFETY NOTICE IF THIS STOVE IS NOT PROPERLY INSTALLED A HOUSE FIRE MAY RESULT FOR YOUR SAFETY FOLLOW THE INSTALLATION DIRECTIONS CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA 223 mm 583 mm 326 mm 6...

Страница 6: ...6 Harman TL300 Specifications Andirons Grate Air Control Front Load Door Top Load Door Handle Ash Door Ash Door Latch Front Load Door Latch Top Load Door Top Load Opening ...

Страница 7: ...d to rain or extremely damp conditions Hardwoods are favored because they are heavier and contain more heating capacity BTU s per load than do softwoods Wood should be split and stored under cover for seasoning a year is recommended Your stove is not an incinerator do not burn garbage painted or treated wood plastics or other debris Keep the area around the stove free from clutter Keep all combust...

Страница 8: ... U S and 60 1524 mm in Canada Due to excessive heat build up at the wall passthrough using double wall pipe horizontal venting is only approved into a masonry chimney See Detailed Clearances on Page 9 Installation Mobile Home Installation The TL300 is approved for mobile home installations in the US only Mobile Home installation should be done in ac cordance with the Manufactured Home and Safety S...

Страница 9: ...Only Top vent vented out back wall with 90o elbow Masonry Chim ney Only 21 15 11 2 28 Top vent ceiling and sidewall clearances 28 17 Single Wall Pipe Top Vent Parallel Installation 20 Double Wall Pipe Parallel Installation 18 27 27 18 Corner Installation with Single and Double Wall Pipe 18 5 13 28 17 15 21 775 mm 500 mm 375 mm 775 mm 50 mm 575 mm 425 mm 600 mm 450 mm 775 mm 500 mm 575 mm 425 mm 70...

Страница 10: ...ize of the flue collar opening Do not use makeshift components No part of the chimney connector may pass through an attic or roof space closet or other concealed space or through a floor or ceiling Whenever possible avoid passing the connec tor through a combustible wall if you must use an approved wall pass through described later in this section Assemble the connector beginning at the flue colla...

Страница 11: ...hest point at which they exit from the roof Then the chimney must extend 2 ft 6 m above the highest point within a 10 ft 3 m radius Thus the 3 foot 2 foot 10 foot rule 3ft Above roof exit point 2ft Higher than anything within 10ft of the chimney NOTE The restriction of not venting more than one appliance to the same flue applies to the U S specifically While it is not recommended that you use the ...

Страница 12: ...pe is a piece of steel pipe used the same way In Canada a breech pipe has ridges or protrusions to lock it firmly into the refractory cement In either case the chimney connector vents to the chimney through the thimble or breech pipe Using a thimble the connector slides completely inside the masonry to the inner edge of the flue liner and may be eas ily removed for chimney and connector inspection...

Страница 13: ...Harman TL300 13 Venting Standard Ceiling Installation with Factory Built Chimney Cathedral Ceiling Installation with Factory Built Chimney ...

Страница 14: ... Minimum of three Sheet Metal Screws per Joint of Chimney Connector Mantel and Trim Protection Floor Protection in Accordance with Solid Fuel Appliance Listing Airtight insulated Clean out Chimney Breach Fireplace Conversion with Non Combustible Wall Floor Protection Combustible Floor Damper Closed and Sealed with Non Combus tible Material ...

Страница 15: ...sembly 1 Clearance for Exterior Chimney or 2 Clearance for Interior Chimney and 2 Clearance for NFPA 211 Type Approved Thimbles Floor Protecion in Accordance with Solid Fuel Appliance Listing Check with your local building codes for clearance Combustible Wall Sheetrock Airtight insulated Clean out Combustible Floor Floor Protection 15 Damper Closed and Sealed with Noncombustible Material Mantel Tr...

Страница 16: ... burned This represents most of the wood s heating capacity The final stage is the charcoal stage where the charcoal burns the remaining heat content out of the fuel Ash re mains after the burning is complete Within the primary firebox two or more of these stages of combustion are occurring simultaneously Operation The Combustion Process Two important controls the top load door handle and the air ...

Страница 17: ...do not have the proper coal bed Open the bypass damper and continue with the process until a significant coal bed is formed To regulate the speed of the optional convection blower adjust the variable speed control from low to high by turning the knob located on the blower The blower speed should be matched to the air control lever setting When the air setting is low the blower should always be at ...

Страница 18: ...r until all cinders have thoroughly cooled This could take days Never use the ash disposal container for other trash Wood ash can be added to your garden or compost g Building and Maintaining the Fire Cont As you begin to operate your stove at higher tem peratures you will notice a hot or unpleasant smell this is just the paint going through the curing process and will disappear after a few fires ...

Страница 19: ... The inside of the fire chamber should be examined for damage to the refractory lining material grates and casting If any bricks have been damaged replace them with Harman replacement parts NOTE Be sure not to insert anything such as a fire poker into the Combustion Package Doing this may cause severe damage to the combustion package See below Glass Replacement If the stove s glass is cracked or b...

Страница 20: ...ut the added ramp tension needed to keep the damper held in the closed position To adjust the ramp the stove MUST be allowed to go out and cool down After the stove has cooled off remove the stove pipe from the stove collar and close the damper Using a flashlight look into the collar About mid point of the damper plate on the backside you will see the adjustment bolt for the ramp tension See figur...

Страница 21: ...tional The TL300 is designed to accommodate the use of outside air introduced directly to the stove The opening is located at the back of the stove pedestal base You ll notice there is a rounded hole with the etching of a larger hole The size needed depends on the length of pipe be ing used see below Check with your local building inspector to find out requirements determining if outside air is ne...

Страница 22: ... list on following page Wood Stove 1 90 06900 1 black 1 90 06900 2 charcoal 1 90 06900 3 goldenfire 1 90 06900 4 Metallic blue 1 90 06900 5 honey glo 1 90 06900 10 Mojave red 1 90 06900 12 Forest green beginning Manufacturing date aug 2007 ending Manufacturing date active ...

Страница 23: ...2 req 3 31 08724 Gasket Top Load Door 1 00 10050 Y Hinge Spacer Qty 2 req 2 00 40021L Lid Hinge Set Bottom 1 00 40022 Y 8 Left Side Shield 2 00 06926P Y 9 Andrion and Andiron Extensions 2 00 05222 1 Y Screw 5 16 18 x 3 4 Grade 5 Zinc Plated Hex Cap Pkg of 100 3 30 1125 100 Y Washer 5 16 Zinc Plated USS Flat Pkg of 100 3 30 0204 100 Y 10 Front Load Door Assembly 1 10 06920A Door Latch 1 00 249119 Y...

Страница 24: ... 2 Wooden Knob 3 40 06956 Y 18 3 Damper Linkage Arm Weldment Includes knob cap 1 10 06937W Y 18 4 Damper Pivot Gear Pkg of 2 2 00 06924 2 18 5 Damper Idler Gear 2 00 06923L Y 18 6 Damper Arm Gear Weldment 1 10 06916W Y 18 7 Damper Shaft Cover Weldment 1 10 06918W 18 8 Damper Linkage Weldment 1 10 249146 Y Hardware Package Includes Drive Arm Washer Pusher Block Bushing Wave Washer Screws 1 00 06901...

Страница 25: ...et Brick Left 3 40 00103 Y 19 6 Side Brick Bracket Pkg of 2 1 00 06945 Y 19 7 Fire Brick 6 x 12 Qty 4 req Pre 551 4 40 86125 Y Post 551 3 40 86125 Y 19 8 Brick Insulation Qty 2 req 3 40 06944 Y 19 9 Grate 2 00 06925B Y 19 10 Inlet Brick Right 3 40 00104 Y 19 11 Right Inside Plate Assembly 1 10 249118A Y 19 12 Shoe Brick Gasket 3 44 06951 Y 19 13 Shoe Brick 3 40 00100 Y Harman Gold Label Pkg of 5 3...

Страница 26: ...26 Harman TL300 This page intentionally left blank ...

Страница 27: ......

Страница 28: ......

Страница 29: ...Harman TL300 29 Notes ...

Страница 30: ...30 Harman TL300 Notes ...

Страница 31: ......

Страница 32: ...Proudly Printed On 100 Recycled Paper ...

Отзывы: