Harman Stove Company Harman Clarity 828i Скачать руководство пользователя страница 16

16

Appendix B: 

De-rating for High Altitude

For U.S. installations, the Clarity Fireplace Insert

is approved for elevations up to 2000 feet using the
factory-installed  burner  injectors.  At  elevations
above  2000  feet,  U.S.  codes  require  a  decrease  in
the input rating by changing the burner injectors to
a  smaller  size.  The  chart  below  lists  by  part  num-
bers the appropriate injectors for both LP and natu-
ral gas at various altitudes.

For  Canadian  installations,  the  Clarity  Fireplace

Insert is approved for elevations up to 1370 meters
(4500  feet).

 For high altitude installations above 1370 meters (4500

feet), consult the local gas  distributor or the authority
having jurisdiction for proper rating methods.

NOTE:  The  difference  in  altitude  derating  require-

ments for the U.S. and Canada is simply a result of dif-
ferences  in  testing  standards  between  the  two  coun-
tries.

If the installer must convert the unit to adjust for vary-

ing altitudes, an information sticker like the one below
must  be  filled  out  and  affixed  to  the  appliance  at  the
time of conversion.

THE  CONVERSION  SHALL  BE  CARRIED  OUT

BY  A  MANUFACTURER'S  AUTHORIZED  REP-
RESENTATIVE  IN  ACCORDANCE  WITH  THE
REQUIREMENTS  OF  THE  MANUFACTURER,
PROVINCIAL  OR  TERRITORIAL  AUTHORI-
TIES  HAVING  JURISDICTION  AND  IN  AC-
CORDANCE  WITH  THE  CURRENT  EDITION
OF  THE  REQUIREMENTS  OF  THE  CAN/CGA-
B141.1  OR  CAN/CGA-B141.2  INSTALLATION
CODES.

LA CONVERSION DOIT ETRE EFFECTUÉE
CONFORMÉMENT AUX RÉGLEMENTATION
PROVINCIAUX EN CAUSE ET AUX
EXIGENCES DES CODES D'INSTALLATION
CAN/CGA-B149.

NATURAL GAS

Front

Harman

Center

Harman

Rear

Harman

Nominal Btu

Altitude

Injector Part  No.

Injector Part  No.

Injector Part  No.

Input Rate

0-2000'

47

Standard

56

Standard

44

Standard

40,000

2000-3000'

47

3-40-25848

56

Standard

45

3-40-25840

38,400

3000-4000'

48

3-40-25849

56

Standard

45

3-40-25841

36,900

4000-5000'

49

3-40-25849

56

3-40-25857

46

3-40-25842

35,400

5000-6000'

49

3-40-25850

57

3-40-25857

47

3-40-25842

34,000

6000-7000'

50

3-40-25850

57

3-40-25857

47

3-40-25843

32,600

7000-8000'

50

3-40-25851

58

3-40-25858

48

3-40-25843

31,300

8000-9000'

51

3-40-25851

58

3-40-25858

48

3-40-25844

30,100

PROPANE

Front

Harman

Center

Harman

Rear

Harman

Nominal Btu

Altitude

Injector Part  No.

Injector Part  No.

Injector Part  No.

Input Rate

0-2000'

57

Standard

71

Standard

55

Standard

40,000

2000-3000'

59

Standard

71

Standard

55

3-40-25854

36,900

3000-4000'

57

Standard

71

Standard

56

3-40-25854

36,900

4000-5000'

58

3-40-25857

71

Standard

56

3-40-25854

35,400

5000-6000'

59

3-40-25857

71

Standard

56

3-40-25855

32,600

6000-7000'

59

3-40-25857

71

Standard

57

3-40-25855

32,600

7000-8000'

60

3-40-25858

71

Standard

57

3-40-25856

30,100

8000-9000'

61

3-40-25858

71

Standard

58

3-40-25856

30,100

Evaluation notes were added to the output document. To get rid of these notes, please order your copy of ePrint IV now.

Содержание Harman Clarity 828i

Страница 1: ...FOLLOW INSTALLATIONDIRECTIONS CONTACT LOCAL BUILDING OR FIRE OFFICIALSABOUT RESTRICTIONSAND INSTALLATION INSPECTION REQUIREMENTS INYOUR AREA CONTACT YOUR LOCAL AUTHORITY SUCH AS MUNICIPAL BUILDING DEP...

Страница 2: ...ne or other flammable vapors and liquids in the vicinity of this or any other appliance ADVETISSEMENT Quinconque ne re spect pas la lettre les instructions dans le pr sent manuel risque de d clencher...

Страница 3: ...ION 11 How to Light the Fire 11 How to Turn Off the Fire 12 MAINTENANCE 12 Removing the Glass 12 Replacing the Gasket 12 Inspecting the Venting 13 Cleaning the Glass 13 Cleaning the Log Set and Firebo...

Страница 4: ...ICING AN APPLIANCE MUST BE REPLACED PRIOR TO OPERATING THE APPLIANCE S ASSURER QUE LE BR LEUR ET LE COMPARTIMENT DES COMMANDES SONT PROPRES VOIR LES INSTRUCTIONS D INSTALLATION ET D UTILISATION QUI AC...

Страница 5: ...o sidewall or combustible trim 10 254 mm Unit to mantel and combustible trim unprotected 12 305 mm In addition to these clearances adequate acces sibility clearance for servicing and proper operation...

Страница 6: ...d vent safety switch which will shut down the main burner if the heater is not properly venting The safety switch will automatically reset after the heater has cooled down The switch will continue to...

Страница 7: ...the front is disengaged Lift the glass door slightly and remove it from the stove Set the glass door aside in a safe place where it will not be damaged WARNING Do not abuse the glass on the Clarity Fi...

Страница 8: ...unds from entering into the gas train apply compounds only to the male pipe threads and only to the first two threads CAUTION TEST ALL JOINTS FOR LEAKS PROPANE NATURAL Inlet Log Positions When Assembl...

Страница 9: ...r for the length of the wire RECOMMENDED WIRE GAUGES Maximum Wire Length Gauge 100 14 60 16 40 18 25 20 15 22 INSTALLING THE INSERT BEFORE OPERATING Gas Pressure Requirements Correct gas pressure and...

Страница 10: ...re according to the directions on page 11 and allow the heater to burn for approximately 15 minutes The flames will increase in length and become more yellow in color as the unit heats up Three adjust...

Страница 11: ...gas control knob slightly and turn it clockwise to OFF NOTE The knob cannot be turned from PILOT to OFF unless it is pushed in slightly Do not force it 6 Wait five 5 minutes to clear out any gas If yo...

Страница 12: ...he latches that secure the door frist remove the two side trim panels Each is held in place by a magnet at the bottom and a magnet at the top Remove the left side trim panel first by pulling the top s...

Страница 13: ...ragile a vacuum cleaner may be used on the firebox If at any time the logs cannot be removed or installed without forcing the cause must be found The logs must never be forced Follow this sequence 1 R...

Страница 14: ...justers Right Trim Panel Blower Speed Switch Right Wing Top Trim Panel Top Wing Right Wing Right Trim Panel Valve Door Ait Inlet Grill Remove to connect thermostat Cord Channel Optional Sunrise Gold F...

Страница 15: ...page 12 2 Disconnect the electrical connections and the gas line fitting from the module 3 Remove the cross log the front logs and the two ember strips following the directions on page 7 4 Pull the mo...

Страница 16: ...ON AND IN AC CORDANCE WITH THE CURRENT EDITION OF THE REQUIREMENTS OF THE CAN CGA B141 1 OR CAN CGA B141 2 INSTALLATION CODES LA CONVERSION DOIT ETRE EFFECTU E CONFORM MENT AUX R GLEMENTATION PROVINCI...

Страница 17: ...rd so that it disengages lift the front edge up then remove it 8 Remove the center burner 9 Remove the front burner 10 Remove the 1 4 20 fasteners and retainer clip that secure the rear burner then re...

Страница 18: ...hen installed must be electrically groundedin accordance with localcodes or in the absence oflocalcodes with thecurrent edition of the NationalElectrical Code ANSI NFPA 70in the United States orthecur...

Страница 19: ...ner Tube 3 40 08225 29 Rear Burner Tube 3 40 08226 30 Burner Plate 1 10 08577 31 1 4 20x5 8SelfTap 3 30 1252006216 32 Burner Retainer 2 00 4211 33 1 4 20x1 bolt 3 30 1252010013 34 AirDeflector 1 10 08...

Страница 20: ...20 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 Burner Assembly...

Страница 21: ...21 36 35 37 40 43 44 41 42 45 39 51 47 48 49 50 55 52 53 58 59 60 61 62 64 57 46 56 54 38 63 65...

Страница 22: ...old Pressure in w c kPa 1 7 0 42 5 9 1 47 Minimum Inlet Pressure in w c kPa 5 0 1 25 11 0 2 74 Maximum Output Btu hr 0 1370 m 27 600 28 400 AFUE seasonal efficiency minimum venting 64 9 67 0 Steady St...

Страница 23: ...d Damage and or repairs including but not limited to remote controls filters fuses knobs glass ceramic brick panels ceramic fiber afterburners door packing tile ceramic log sets paint batteries or bat...

Отзывы: