background image

6

Manual Start Up

Starting  First  Fire

Igniter Switch to"MANUAL" (down position)

Make sure the unit is plugged into a 120

VAC, 60 HZ electrical source. The power light
should be the only light lit.

1.  Turn  FEED ADJUSTER  to  desired  feed

rate

. No. 4 is good for most pellets.

4

2. Turn the MODE SELECTOR

 to “OFF” and

then to the desired mode.

  This will reset

control and start the combustion motor.

3. Turn the TEMPERATURE DIAL to the de-

sired setting.

4. Clean burn pot with scraper if necessary.

5

5. Fill burn pot with pellets, only level with

front edge.

 (Do Not Over Fill).

6. Add starting gel on top of the pellets.

 Stir

gel into pellets for fast lighting.

7. Light starting gel with a match, and close

the door.  

Operation will begin when the fire

reaches the proper temperature.

3

8. Fill hopper with pellets and remove ashes

as required.

1, 6

1. Fines are small pieces of broken pellets (sawdust). Fines
do not flow easily and often build up on the hopper funnel
bottom angles. These fines can be pushed into the feeder
opening and then fill the hopper with pellets. As the system
works, they will be burned.
2. The "TEST" cycle will operate the feeder motor for exactly
one minute. Turning to "TEST" again and again may purge too
much fuel into the burn pot causing excessive smoke on start-
up.
3. The firebox low pressure switch will not allow the auger
motor or the igniter element to operate if the view door or the
ash pan door are open.
4. Adjust Feed Rate. If this is your first fire or you are trying
different pellets, set the feed adjuster to #4, Fig. 5. This is a
conservative number and will probably need to be increased.
After you know a feed rate setting that works well, use that
setting. Remember, if your feed rate is too high you may waste
fuel.
5. This is usually a weekly maintence procedure. Cleaning the
burn pot with the scraper with a small amount of new fuel in the
bottom is not a problem. First, scrape the ashes on the front of
the burn pot into the ash pan. Then scrape the holed surface
downward into the burn pot. When the stove is ignited these
scrapings will be pushed out by the feeder.
6. The ash pan can hold the ashes from approximately 1 ton of
premium fuel. This  means the ashes will only  need to be
emptied a few times a year.
7. Setting the feed adjuster # for maximum burn: With the unit
burning in "AUTO", turn to "Stove Mode" and put the fan on "H".
Set the Temperature Dial to #7. Allow the unit to burn for about
30 minutes and check ash on front of burn pot. Fig. 9. If the ash
line is larger than 1", turn the feed adjuster from #4 to #5. Allow
another 30 minutes of burn time and check again. If , at #6
setting,  a 1"  or less  ash bed  is not  obtainable, i t  is not  a
problem. The 1" ash bed is only a maximum burn rate and at
most normal settings the ash bed will be larger.

Fig. 6

Fig. 7

1"

See Note 7.

NEVER USE GASOLINE, GASOLINE-TYPE LANTERN
FUEL, KEROSENE, CHARCOAL LIGHTER FLUID, OR
SIMILAR LIQUIDS TO START OR 'FRESHEN UP' A
FIRE IN THIS HEATER. KEEP ALL SUCH LIQUIDS
WELL AWAY FROM THE HEATER WHILE IN USE.

Warning

Notice when using Optional Battery Back-Up:

If  a  power  outage  is  expected,  change  the  toggle
switch to Manual Mode. The Harman 502H Battery
Backup  is  incapable  of  powering  the  igniter.  If  an
automatic  ignition  is  attempted  while  the  stoves  is
being powered by the battery back up, it may cause
damage  to  both  the  stove  and  the  battery  backup
unit.

Fig. 5

Evaluation notes were added to the output document. To get rid of these notes, please order your copy of ePrint IV now.

Содержание Accentra The Harman Accentra Pellet Insert

Страница 1: ...OR YOURSAFETY FOLLOW INSTALLATIONDIRECTIONS CONTACT LOCAL BUILDING OR FIRE OFFICIALSABOUT RESTRICTIONSAND INSTALLATION INSPECTION REQUIREMENTS INYOUR AREA CONTACT YOUR LOCAL AUTHORITY SUCH AS MUNICIPA...

Страница 2: ...you get just the right amount of heat 24 hours a day This remarkable technology lets you fill the hopper set the desired temperature and walk away TheAccentra insert lights automatically brings the ro...

Страница 3: ...otor or the igniter element to operate if the view door is open 4 Adjust Feed Rate If this is your first fire or you are trying different pellets set the feed adjuster to 4 Fig 1 This is a conservativ...

Страница 4: ...om temperature Therefore as it gets colder more pellets will be burned automati cally The distribution blower speed will vary according to the position of the mode selector pointer and fire size Ignit...

Страница 5: ...d will probably need to be increased After you know a feed rate setting that works well use that setting Remember ifyourfeed rateis too high you may waste fuel 5 This isusually a weekly maintence proc...

Страница 6: ...et at 5 or less the distribution fan will not operate A 5 on the temperature dial and a 5 on the feed adjuster is approximately 80 output It is not necessary to oper ate the distribution blower below...

Страница 7: ...e Test Runsall motorsatfull speed forone minute to check operation After two minutes the stove will go to minimum burn and the blowers will alternate fromhigh to low every minute to remind you that yo...

Страница 8: ...y underneath the cast top are 2 1 4 flange head bolts See Fig 12 These bolts pull the cast top and lid assembly down onto the hopper gasket to seal the hopper They also allow for a small amount of fro...

Страница 9: ...in place Note The heat exchanger covers will tilt to the front when the center medallion is removed pproximatlely 12 but the left side tube requires the total length of the brush to be used Removing t...

Страница 10: ...ide wings should be standing up aligned with the side of the mounting frame and slid inward towards the center Note The wings mount on the rear side below the notch and on the front side above the not...

Страница 11: ...ireplace face 6 You must now decide whether to install the room sensor as a wall sensor or as a return air sensor Harman highly recommends that the room sensor be installed If you are installing the r...

Страница 12: ...or as a return airsensor Insert the sensor end of the wire from the rear of the mounting frame through the hole as shown in fig 24 Tyrap the sensor end so that the sensing tip is in the middle of the...

Страница 13: ...ationis used with orwithout outside air make sure the flue pipe termination clearances are followed as per the manufacturers recommendations 16 Place the stove body on the mounting shell gasketed rail...

Страница 14: ...dy is latched into place and the front door is closed Connecting the power cord The white from the mounting frame connects to the white of the insert body The black from the mounting frame connects to...

Страница 15: ...ck for tears or signs that the gasket is not sealing properly Fig 36 19 Inspect the silicone sponge gasket on the top edge of the hopper If it is okay put the cast top hopper lid assembly see Fig 35 i...

Страница 16: ...els open and close freely for good control board access 22 Slide the stove body into the mounting frame Note The two spring latches on the bottom right and left side of the body must be in the proper...

Страница 17: ...tion area This is the area that comes closest to the mounting frame as the unit is slid in and out of the frame 11pin socket on rear ofcontrol board 6 amp glass fuse Fig 40 Hopper lid foam gaskets Cas...

Страница 18: ...fire is lit check and record the high and low draft readings A simple draft test should be performed after completing the flue pipe installation To record the results for future reference 1 Plug unit...

Страница 19: ...ough the 5 holes in the base plate shown in Fig 26 2 The unit must also be connected for the out s ide a ir S e e pa ge 21 All mobile home ins ta lla tions re quire the us e of o uts ide a ir this wil...

Страница 20: ...rtical 90o or T 2 0 Vertical 45o 1 0 Horizontal 90o or T 4 0 Horizontal 45o 2 0 Longruns of flex orPL vent pipe installeddirectly vertical fromtheflue stub may require more frequent cleaning due to fl...

Страница 21: ...vent pipe wall and ceiling pass through fittings to go through combustible wallsand ceilings Be sure to usea starting collar toattach the venting sys tem to the stove The starting collar must be seal...

Страница 22: ...e event of a power failure A 4 inch stainless steel flex pipe is needed for the flue pipe and3 aluminumor Stainless Steel Flex Pipe is used for the intake In Canada and some places in the US it is re...

Страница 23: ...llent venting for nor mal operation and in a fireplace with inadaquate flue space or a height of over 30 feet A 3 or 4 PL vent pipe should be used with an optional swivel flue stub NOTE The flue stub...

Страница 24: ...t would be the responsibility of the installer to supply something to fill this space and be strong enough to support the front of the insert As for the size and position of the existing chim ney and...

Страница 25: ...n the UL label Fig 55 Fig 56 Accentra Insert Zero Clearance Cabinet Be sure to use ap provedpellet ventpipe wall and ceiling pass through fittings to go through com bustible wallsand ceilings Be sure...

Страница 26: ...red fromthe horizontalcenter line of the regu lator 1 I The clearance to service regulator vent outlet must be a minimum of 6 feet 1 J The clearance to a non mechanical air sup ply inlet to the buildi...

Страница 27: ...If the ashes are disposed of by burial in soil or otherwise locally dispersed they should be retained in the closed container until all cinders have thoroughly cooled Soot and fly ash Formation and n...

Страница 28: ...connectors These connections between the hot leads the wires inside the burn pot and the cold leads the wires from the control board are always pulled to the inside rear of the feeder body Not coiled...

Страница 29: ...rear flange of the burnpot They should be checked for blockage and cleaned with a vacuum if necessary Note The bottom of the flame guide has 2 notches that match the holes Cleaning the Heat Exchanger...

Страница 30: ...blade by pulling it directly away from the blower housing The cord on the motor is long enough to allowthe motor to be set down on the black plastic fan cover This allows for easy access to inspect a...

Страница 31: ...igniter element This switch is connected into the AC high voltage wires therefore the control may show the feeder motor and igniter lights on but they are not 31 The Control Board ESP combination is...

Страница 32: ...e FIRE HAS GONE OUT 1 No pellets in hopper 2 Draft setting is too low 3 Something is restricting fuel flow 4 Feed motor or draft motor has failed 5 Power failure or blown fuse SMOKE IS VISIBLE COMING...

Страница 33: ...side Air Size 3 inches Fuse Rating 6 amp BTU Range 0 to 42 000 Feed Rate 75 lbs hr on minimum on maintenance 5 lbs hr on maximum Vent Size 4 inch Pellet Vent Pipe standard 3 inch Pellet Vent Pipe opti...

Страница 34: ...35 Accentra Insert Wiring Diagram J2...

Страница 35: ...52007514 HCS 3 8 16x 3 30 1371608713 Bearing Retainer 2 00 04035 Auger 3 50 00365 Intake Air Box Assembly 1 10 674045 Differential Pressure Switch 3 20 9301 Feeder Body Weldment 1 10 00910 Slide Plate...

Страница 36: ...3 21 00661 Combustion Blower 3 21 08639 Distribution Blower 3 21 47120 Tailpipe Insulator 3 44 674102 White Black Control Knob 3 3 31 00968 Control Knob Shaft 3 3 31 00982 Front Glass w gasket 3 40 67...

Страница 37: ...and venting problems are not covered Damage and or repairs including but not limited to remote controls filters fuses knobs glass ceramic brick panels ceramic fiber afterburners door packing tile cera...

Отзывы: