![Harken CLR 600 Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/harken/clr-600/clr-600_installation-and-maintenance-manual_4065514029.webp)
29
CLR Mooring Winch
Installation and Maintenance Manual - Mod.A
1. Before connecting the cable terminals to motor, remove the sheaths from the central spindles of the
motor contacts.
Refer to the following chart for wire size:
Total distance between winch and battery
Current
voltage
Under 16.4 ft
AWG
Under 5 m
mm
2
16.4 - 32.8 ft
AWG
5 m - 10 m
mm
2
32.8 - 49.2 ft
AWG
10 m - 15 m
mm
2
49.2 - 65.6 ft
AGW
15m - 20 m
mm
2
12 V
2
32
0
50
00
70
000
95
24 V
5
16
3
25
2
35
0
50
8.3 Electric motor installation procedure
2. Insert the cables coming from the Dual Function Control Box into the sheaths
3. Crimp the cable terminals
4. Unscrew nuts and remove washers from the central spindles of the motor contacts