OPERATION
TO TURN OFF GAS TO APPLIANCE
TEMPORARY SHUTDOWN PROCEDURE:
To turn off main burner only, depress the knob and turn it
Clockwise
as far as it will go. Do not force.
COMPLETE SHUT-DOWN PROCEDURE:
Turn off all electrical power in firebox. Turn gas control knob
clockwise to the"OFF" position.
Controlling Heat Output
* The heat output can be controlled by the vent free burner
control knob.
Important Safeguards
1. To avoid personal injury, do not touch hot surfaces
when the appliance is operating. Touch only the piezo
igniter and control knob.
Hot Surfaces
a. Grate
b. Burner
c. Logs
d. Surfaces above the opening of the fireplace
2. Although your gas logs are very realistic in
appearance, it is not a real wood-burning fireplace and
must not be used for burning any material.
* To avoid irreparable damage to the appliance or
personal injury, matches, paper, garbage, or any
other material must not be placed or thrown on top
of the logs or into the flames.
Close supervision is necessary when the appliance is
being operated near children.
Avoid any drafts that alter burner patterns. Do not allow
fans to blow directly into the fireplace. Ceiling fans
may create drafts that alter burner flame patterns.
Sooting and improper burning will occur.
Cleaning and Servicing
Installation and repair should be done by a qualified service
person. The appliance should be inspected before use and at
least annually by a professional service person. More frequent
cleaning may be required due to excessive lint from carpeting,
bedding material, etc. It is imperative that control components,
burners and circulating air passageways of the appliance be
kept clean.
* If the flames show any unusual shapes or behavior,
or the burners fail to ignite properly, then the burner
holes may require cleaning.
WARNING:
TURN OFF VENT FREE BURNER
SYSTEM AND ALLOW TO COOL BEFORE CLEANING
OR SERVICING.
Annual Cleaning and Inspection
1. If removing logs, when reinstalling, refer to "Log
Assembly Diagram" for correct log placement.
2. Do not use cleaning fluids to clean logs or any part
of the heater.
3. Brush logs with a soft bristle brush or vacuum with
brush attachment.
4. Vacuum loose particles and dust from the front and
rear burner ports, gas control, piezo cover, and grate.
5. Inspect and clean ODS pilot for operation and
accumulation of lint at air intake holes.
6. Verify flame pattern and log
placement for proper operation.
7. Verify smooth and responsive ignition
of main burner and rear burner. Refer to
page 10 for pictorial sketch of proper
operation.
Remove
Lint
or
Particles
1. Dealer or qualified inspector - follow the above
steps for proper servicing and inspection.
Monthly Cleaning
Pg. 11