RGA 2-72
INSTALLATION AND OPERATION GUIDE FOR
HARGROVE
GAS LOGS
PROPANE GAS
ADEQUATE FIREPLACE VENTILATION IS REQUIRED FOR SAFETY.
GAS LOGS MUST BE INSTALLED BY PERSONNEL QUALIFIED FOR
INSTALLING GAS APPLIANCES.
NOTE!
READ INSTRUCTIONS FULLY BEFORE INSTALLING OR OPERATING.
INSTALLERS LEAVE THESE INSTRUCTIONS WITH THE CONSUMER!
Hargrove Manufacturing Corporation uses refractory material to create ceramic logs. Each log is hand
finished to assure the most realistic, detailed log available. The gas log burner system is designed to
burn like wood with a yellow smoky flame. For this reason the gas log set must be burned only in a
fully vented, non-combustible fireplace with the
damper completely open
and the chimney free of
any obstructions or restrictions. The fireplace must be designed and approved to burn wood. The
minimum permanent, free opening provided by the fireplace chimney must be 8” in diameter (50
square inches). The realistic yellow flame produces carbon monoxide and soot. Under normal
conditions these products are exhausted up the chimney. If fumes or soot from the gas burning are
evident in the room when the damper is fully open, it indicates that the fireplace draft is defective. Do
not operate your gas log set until the fireplace draft is corrected.
ADEQUATE VENTILATION IS REQUIRED.
IT IS THE HOMEOWNERS RESPONSIBILITY TO ASSURE
THEIR FIREPLACE HAS ADEQUATE DRAFT.
WARNING: IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A
FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL
INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY
IF YOU SMELL GAS:
1. OPEN WINDOWS
2. DON’T TOUCH ELECTRICAL
SWITCHES
3. EXTINGUISH ANY OPEN FLAMES
4. IMMEDIATELY CALL YOU GAS
SUPPLIER
THE SIZE CHART BELOW INDICATES THE
MINIMUM SIZE FIREPLACE OPENINGS IN,
WHICH DIFFERENT SIZE GAS LOG SETS
CAN BE INSTALLED.
FLAMMABLE VAPORS MAY BE DRAWN
BY AIR CURRENTS FROM OTHER AREAS
OF YOUR HOUSE TO THIS APPLIANCE.
FIREPLACE SIZES
GAS LOG
SET SIZE
DEPTH
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR
OTHER FLAMMABLE VAPORS AND LIQUIDS
IN THE VACINITY OF THIS OR ANY OTHER
APPLIANCE.
FRONT
WIDTH
16”
13”
20”
18”
13”
22”
24”
14”
28”
30”
14”
34”
36”
15”
40”
For models tested through OMNI-Test Laboratories,
Inc., to RGA2-72. For model number and O-TL seal
refer to attached name plate.