WARNING:   This appliance assembly contains burner orifices specifically for the input 
gas  and  Btu  rating.   Modifying  or  failure  to  use  the  factory  orifice  may  cause  property 
damage, personal injury or loss of life. 

 

1.  It is recommended that adults be present when this gas appliance is operating.  It is recommended that this unit 

is not left burning when unattended or while anyone is sleeping. 
 

2.  Do not use a natural gas set for propane or a propane set for natural gas. If the gas type is not correct. DO NOT 

INSTALL. Contact your dealer for immediate assistance. 
 

3.  There are many different local codes for gas fire logs.  The installation and the provision for combustion and 

ventilation air must conform to local codes and, or in the absence of local codes, with the National Fuel Gas 
Code ANSI Z223.1 

– (most current revision). 

 

4.  Gas log sets must be installed by personnel qualified for installing gas appliances. 

 

5.  This appliance must be installed  only  in a solid-fuel burning fireplace  with a  working flue and constructed  of 

noncombustible materials.   Solid fuels are not to be  burned in a fireplace  where  a decorative appliance has 
been installed. 

 

6.  A permanent free opening must be provided by either the fireplace chimney or chimney damper to vent flue 

gasses.  Any chimney damper must be fixed in a manner, which will maintain the permanent free opening at all 
times.    Use  Table  II  to  determine  the  minimum  permanent  free  opening  based  on  chimney  height  and  the 
appliance Btu input rating.  Refer to the Damper Stop section for additional directions. 

 

7.  The  minimum  free  opening  is  based  only  on  two  factors;  chimney  height  and  Btu  input  rating.    Many  other 

factors affect the fireplace drafting.  It is the homeowner’s responsibility to assure their fireplace has adequate 
draft.  If fumes or soot from the gas burning are evident in the room when the damper is fully open, it indicates 
that the fireplace draft is defective.  Do not operate your gas log set until the fireplace draft is corrected.  Consult 
your fireplace specialist. 

 

8.  A fireplace screen must be in place when the appliance is operating and, unless other provisions for combustion 

air are provided, the screen shall have an opening(s) for introduction of combustion air. 

 

9.  When glass fireplace doors are used, always operate gas log set with the doors fully open to allow for proper 

combustion air and to keep control valves from overheating. 

 

10.  The minimum inlet supply pressure for the purpose of input adjustment is 5.0 inches (natural gas) 11 inches 

(propane  gas)  in  water  column.   The maximum  inlet  supply  pressure  is  10.5  inches  (natural  gas)  13  inches 
(propane gas) in water column. 

 

11.  The appliance and its individual shut-off valve must be disconnected from the gas supply piping system during 

any pressure testing of that system at test pressures in excess of 1/2 psig (3.5kPa).  The appliance must be 
isolated from the gas supply piping system by closing its individual manual valve during pressure testing equal 
to or less than 1/2 psig (3.5kPa). 

 

12.  The fireplace chimney or venting system should be examined annually and cleaned as required by a qualified 

agency. 

 

13.  After burning for several hours the logs become fragile and should not be handled.  Knocking or rubbing logs 

can cause concrete to crumble and is not covered under the warranty. 

 

14.  To clean the logs, use a soft dry paintbrush for periodic dusting of the gas fire logs.   

 

15.  To clean the burner, shut off the gas supply, remove the burner pan media, and vacuum the burner ports.  After 

cleaning, replace burner pan media and light the pilot according to the lighting instructions. 

 
 
 

IMPORTANT PRE-INSTALLATION AND FIREPLACE SAFETY INFORMATION 

  2 
 

 

Содержание HC Series

Страница 1: ...taller service agency or the gas supplier NOTE This appliance is only for use with the type of gas indicated on the rating plate Solid fuels shall not be burned in a fireplace where a decorative appliance is installed This Hargrove vented gas log set is to be installed only in a solid fuel burning fireplace with a working flue and constructed of noncombustible material The installation including p...

Страница 2: ...to assure their fireplace has adequate draft If fumes or soot from the gas burning are evident in the room when the damper is fully open it indicates that the fireplace draft is defective Do not operate your gas log set until the fireplace draft is corrected Consult your fireplace specialist 8 A fireplace screen must be in place when the appliance is operating and unless other provisions for combu...

Страница 3: ...at will fit in a fireplace the width at the front of the fireplace is the critical dimension Table I below indicates the minimum front width for each size set TABLE II Free opening area of chimney damper for venting combustion products from decorative appliances for installation in vented fireplaces Minimum size of chimney flue is 8 diameter Minimum Permanent Free Opening Square Inches SPECIFICATI...

Страница 4: ...S LINE Ensure gas line is in safe condition and that it is adequate for the installation Check gas line sizing to ensure it is properly sized for the appliance For ease of installation gas line should be located on the right side of the fireplace when possible Turn the gas supply line off and you are ready to begin burner installation Attach the damper stop clamp to the fireplace damper blade Posi...

Страница 5: ...lator 4 SKC C Gas Control Valve 5 PG 5 8 Pedestal Grate 6 FCNW 18 x2 Non Whistling Gas Flex Connector 7 DS Damper Stop 8 RW Glowing Embers 9 VC Volcanic Cinder 10 SD 10 Sand NG sets only 11 VM Vermiculite LP sets only 12 49 6 6Z2 Orifice NG sets only 13 AM3 8x3 8 Air Mixer LP sets only NOTE Replacement parts can be ordered from your local Hargrove dealer 1 2 3 4 5 6 7 8 9 10 11 12 13 ...

Страница 6: ... for installation Connect to gas IMPORTANT The minimum inlet supply pressure for the purpose of input adjustment is 5 0 inches natural gas 11 inches propane gas in water column The maximum inlet supply pressure is 10 5 inches natural gas 13 inches propane gas in water column BURNER AND GRATE POSITIONING Check that the gas is turned off Center the burner on the fireplace floor The burner should be ...

Страница 7: ...s for leaks using a soapy solution NOTE if the pilot will not stay lit after several tries turn the control off and call a technician IMPORTANT These controls are factory preset and will not normally require additional adjustment of the pilot flame If field adjustment of the pilot flame is required adjust using the pilot adjustment screw The 90 degree pilot should produce 2 flames about 1 1 in 2 d...

Страница 8: ... logs carry a limited lifetime warranty against breakage in the original fireplace Warranty does not include labor This warranty is void if excessive handling after burning causes breakage All accessories and metal parts carry a two year limited warranty in the original fireplace Items will be replaced during this period for the cost of shipping VOLCANIC CINDER PLACEMENT The black volcanic cinders...

Страница 9: ...h has been underwater LIGHTING INSTRUCTIONS GAS OUTLET GAS INLET Pilot Adjustment Screw Pilot Gas Supply 4 Find pilot follow metal tube from the gas control behind the burner pan Pilot Burner Thermocouple 1 STOP Read the safety information above on this label 2 Push in gas control knob slightly and turn clockwise to OFF CONTROL KNOB NOTE Knob cannot be turned from PILOT to OFF unless knob is pushe...

Страница 10: ...ty Some states do not allow limitations on how long an implied warranty lasts so the above limitations may not apply to you 3 HARGROVE MANUFACTURING CORPORATION WILL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL SPECIAL OR CONTINGENT DAMAGES YOU MIGHT SUFFER AS A RESULT OF A CLAIM UNDER THIS WRITTEN WARRANTY OR ANY IMPLIED WARRANTY Some states do not allow the exclusion or limitation of incidental or...

Отзывы: