Proceed as follows to connect the charging station to the mains:
1
Make sure again that all
line circuit breakers
and
current circuit breakers
in the
supply line are
deactivated
.
2
Remove the housing cover of the charging station.
2.1
Unscrew the two screws on the lower side of the lid
2.2
Carefully lift off the housing cover
2.3
Carefully lift off the touch guard and pull out the plug connection of the LED-
indicators. You can then remove the touch guard.
3
Now switch off the circuit breaker in the charging station (switch position 0 OFF).
4
Insert the supply line from below into the corresponding cable gland. Then clamp
the stripped wires of the supply line into the supply line terminals according to the
terminal labeling (max.10 mm²). The
underlined phases
indicate the terminals for
the
right-hand charging connection.
Incorrect connection of the wires can cause damage to the charging station!
Caution:
In the case of a Wallbox with two charging points and only one supply
line,
type B or type EV RCD
must be pre-installed in the supply line.
Observe jumpers!
Installation and operating manual
cPH2
charging station
Version: 1.0.9
16
Figure 1: dual supply line
L1
L1
L1
L1
L2
L2
L2
L2
L3
L3
L3
L3
N
N
N
N
PE
PE
PE
PE
Figure 1: single supply line
L1
L1
L1
L1
L2
L2
L2
L2
L3
L3
L3
L3
N
N
N
N
PE
PE
PE
PE