10
Optional transducers
Revolutions and area-meter transducer
The south side of the
magnet must face the
transducer.
Distance between them
must be 5 to 7 mm.
An adjustable hose clamp
drilled with a 4.5 mm hole
can be used to attach the
magnet to the shaft.
Analog transducer
Input is 4 to 20 mA.
Transducer cables are fed through the Scanbox grommets. Connection
is directly to the Scanbox circuit board.
NOTE: A 2 metre cable extension set with plugs and sockets is avail-
able. HARDI ref. no. is 741610.
Cables
All the cables and wires must be routed so they do not get pinched,
snagged or melted. The transducer cables should be shortened if
necessary.
NOTE: Although the system meets standards EN 50081-1 (1992) for
generic emission and EN 50082-2 (1995) for generic immunity, some
communication systems (e.g. 2 way radio, cellular telephones) may
cause interference with the sprayer computer. Keep communication
system units and cabling away from the sprayer computer units and
cabling. If interference is noted, avoid using the communication system.
T165-0005
T165-0006
5-7 mm
5-7 mm
Connection pins