COMMANDER OPERATOR’S MANUAL
FAULT
System will not flush (pump,
control, and boom)
System will flush, but not
rinse.
Rinse nozzle has poor
output.
PROBABLE CAUSE
Various
Rinse valve
Various
CONTROL/REMEDY
Flush valve not in correct position.
P.T.O. not engaged
Rinse valve not in correct position.
Bad flush valve or suction side air leak.
Rinse valve not in correct position.
Chemical filler pressure selection not in
correct position (if so equipped.
Flush & Rinse™ System problems
Troubleshooting
FAULT
Filler hopper will not empty.
Filler hopper empties too
slow.
Filler hopper backfills when
bottom tank discharge valve
is open.
PROBABLE CAUSE
Various
Various
Various
CONTROL/REMEDY
Pressure selection valve not in correct position.
Sprayer pump not running.
Bottom tank discharge valve not open all the way.
Restrictor cone from pump supply not the
correct size: Black - 1302 & 363 pump
White - 463 pump
Restrictor cone from pump supply not the
correct size: Black - 1302 & 363 pump
White - 463 pump
Restrictor cone missing.
Restrictor cone on wrong side of the valve.
Chemical Filler problems