5 - Operation
44
Minimum Height Mode
Minimum height mode is normally used only for systems with five sensors (severe terrain kit). Since the five sensor system
has two wing sensors that average the height, it is possible to have a boom tip close to the ground while still maintaining
an acceptable average height. The minimum height defines the lowest height in which a single sensor on the wings is
allowed to go.
The relative "
Rel
" setting defines the number as the distance below the target height. The fixed "
Fixd
" setting defines
the number as the distance above the ground.
1.
To access the minimum height mode settings, toggle "SENSOR DISPLAY" from the run screen until you see "
More?
".
Toggle "AUTO (YES)" to accept.
2.
Toggle "SENSOR DISPLAY" again until you see "
Other?
". Toggle "AUTO (YES)" to accept.
3.
Use the "+/-" switch to change the settings.
Valve and Air Temperature
Pressing and holding "SETUP" will cycle the display between the valve block temperature "
VT
" and the air temperature
"
AT
".
Metric (cm height) = Celsius
Imperial (inch height) = Fahrenheit
MHM Rel
Minimum Height Mode
MHS 50
Minimum Height Soil mode
MHC 50
Minimum Height Crop mode
Units cm
Units (cm or inches)