Troubleshooting

problem

possible Causes

probable Solutions

Engine will not start

FUEL RELATED:
1.  No fuel in tank or fuel valve closed. 

 

 

2.  Choke not in START position, cold engine.
3.  Gasoline with more than 10% ethanol 

used. (E15, E20, E85, etc.) 

 

 

4.  Low quality or deteriorated, old gasoline. 

 

 

5.  Carburetor not primed.
6.  Dirty fuel passageways. 

7.  Carburetor needle stuck.  

Fuel can be smelled in the air.

8.  Too much fuel in chamber. This can be 

caused by the carburetor needle sticking. 

 

9.  Clogged Fuel Filter.

FUEL RELATED:
1.  Fill fuel tank with fresh 87+ octane stabilizer-treated 

unleaded gasoline and open fuel valve.

 

Do not use gasoline with more than 

10% ethanol (E15, E20, E85, etc.).

2.  Move Choke to START position.
3.  Clean out ethanol rich gasoline from fuel system.  

Replace components damaged by ethanol.  Use fresh 

87+ octane stabilizer-treated unleaded gasoline only. 

  

Do not use gasoline with more than 

10% ethanol (E15, E20, E85, etc.).

4.  Use fresh 87+ octane stabilizer-treated 

unleaded gasoline.

 

Do not use gasoline with more than 

10% ethanol (E15, E20, E85, etc.).

5.  Pull on Starter Handle to prime.
6.  Clean out passageways using fuel additive.  

Heavy deposits may require further cleaning.

7. 

Gently

 tap side of carburetor float 

chamber with screwdriver handle.

8.  Turn Choke to RUN position.  Remove spark plug and 

pull the start handle several times to air out the chamber.  

Reinstall spark plug and set Choke to START position.

9.  Replace Fuel Filter.

IGNITION (SPARK) RELATED:
1.  Engine Switch at OFF position.
2.  Spark plug cap not connected securely.
3.  Spark plug electrode wet or dirty.
4.  Incorrect spark plug gap.
5.  Spark plug cap broken.
6.  Incorrect spark timing or 

faulty ignition system.

IGNITION (SPARK) RELATED:
1.  Turn Engine Switch to ON position.
2.  Connect spark plug cap properly.
3.  Clean spark plug.
4.  Correct spark plug gap.
5.  Replace spark plug cap.
6.  Have qualified technician diagnose/

repair ignition system.

COMPRESSION RELATED:
1.  Cylinder not lubricated.   

Problem after long storage periods.

2.  Loose or broken spark plug.   

(Hissing noise will occur  

when trying to start.) 

3.  Loose cylinder head or damaged 

head gasket.  (Hissing noise will 

occur when trying to start.)

4.  Engine valves or tappets 

mis-adjusted or stuck.

ENGINE OIL RELATED:
1.  Low engine oil. 

2.  Engine mounted on slope, 

triggering low oil shutdown.

SPARK ARRESTOR RELATED:
1.  Spark Arrestor clogged with soot.

COMPRESSION RELATED:
1.  Pour tablespoon of oil into spark plug hole.  Crank 

engine a few times and try to start again.

2.  Tighten spark plug.   

If that does not work, replace spark plug.   

If problem persists, may have head 

gasket problem, see #3.

3.  Tighten head.   

If that does not remedy problem, replace head gasket. 

4.  Have qualified technician adjust/

repair valves and tappets.

ENGINE OIL RELATED:
1.  Fill engine oil to proper level.  Check engine 

oil before EVERY use.

2.  Operate engine on level surface. Check engine oil level. 

SPARK ARRESTOR RELATED:
1.  Clean and replace Spark Arrestor.

Follow all safety precautions whenever diagnosing or servicing the generator or engine.

Содержание Predator 9500

Страница 1: ...his is a poison you cannot see or smell NEVER use inside a home or garage EVEN IF doors and windows are open Only use OUTSIDE and far away from windows doors and vents When unpacking make sure that th...

Страница 2: ...ement 459cc Compression Ratio 8 5 1 Engine Type Horizontal Single Cylinder 4 stroke OHV Cooling System Forced air cooled Fuel Type 87 octane stabilizer treated unleaded gasoline Capacity 6 8 Gallons E...

Страница 3: ...of Eye Injury Wear ANSI approved safety goggles with side shields Read the manual before set up and or use Symbol Property or Statement WARNING marking concerning Risk of Hearing Loss Wear hearing pro...

Страница 4: ...Operating Precautions 1 CARBON MONOXIDE HAZARD Using a generator indoors CAN KILL YOU IN MINUTES Generator exhaust contains carbon monoxide This is a poison you cannot see or smell OFF run STarT LOW O...

Страница 5: ...ator unattended when it is running Turn off the generator and remove safety keys if available before leaving the work area 24 The generator can produce high noise levels Prolonged exposure to noise le...

Страница 6: ...shields among other guards 3 Keep all electrical equipment clean and dry Replace any wiring where the insulation is cracked cut abraded or otherwise degraded Replace terminals that are worn discolore...

Страница 7: ...ied electrician if you are not qualified to do so 2 To ground the Generator connect a 4 AWG grounding wire not included from the Grounding Terminal on the Control Panel to a grounding rod not included...

Страница 8: ...Fuel Gauge Control Panel Air Filter Spark Plug Battery Access Panel Combination Switch Oil Fill Access Door Figure B Generator Components WARNING TO PREVENT SERIOUS INJURY Follow Parallel Kit instruc...

Страница 9: ...10W 30 oil is recommended for general use 6 Thread the Oil Fill Cap Dipstick back in clockwise and replace the Oil Fill Access Door NOTICE Do not run the engine with too little oil Engine will shut of...

Страница 10: ...ngine starts Do not let the Starter Handle snap back against the housing Hold it as it recoils so it doesn t hit the housing 5 After the engine starts allow to run for 20 seconds then turn the Combina...

Страница 11: ...T SERIOUS INJURY AND DEATH FROM CARBON MONOXIDE INHALATION The Carbon Monoxide sensor is an additional layer of protection only Do not use the Generator in any area or situation that will allow carbon...

Страница 12: ...s 12VDC circuit protection is tripped reduce the load and press the Reset Button next to the outlet Connecting 120VAC Loads to the Generator Calculate Power Draw Power draw can be calculated by multip...

Страница 13: ...Generator again 5 Restart the Engine and reconnect devices while being careful to not overload Generator Low Oil Indicator 1 If the Engine oil level is too low the LOW OIL light turns on and the Engi...

Страница 14: ...al conditions use the following procedure to shut off the Generator 1 Turn all electrical load devices off and unplug them from the Generator If the Economy Switch is ON turn it to the OFF position 2...

Страница 15: ...Maintenance and Lubrication Schedule Note This maintenance schedule is intended solely as a general guide If performance decreases or if equipment operates unusually check systems immediately The main...

Страница 16: ...e CAUTION Oil is very hot during operation and can cause burns Wait for engine to cool before changing oil 1 Make sure the Engine is stopped and is level 2 On the right side of the Generator loosen th...

Страница 17: ...oil 5 Install the cleaned filter 6 Secure the Air Filter Cover and replace the Access Panel before use Spark Arrestor Maintenance TO PREVENT SERIOUS INJURY AND FIRE Operate only with proper spark arr...

Страница 18: ...with a fuel stabilizer additive Follow fuel stabilizer manufacturer s recommendations for use Refer to Checking and Filling Fuel on page 16 Aged gasoline that has not been treated with stabilizer ahe...

Страница 19: ...r Reinstall spark plug and set Choke to START position 9 Replace Fuel Filter IGNITION SPARK RELATED 1 Engine Switch at OFF position 2 Spark plug cap not connected securely 3 Spark plug electrode wet o...

Страница 20: ...technician service magneto 7 Secure spark plug cap Engine stops when under heavy load 1 Dirty air filter 2 Engine running cold 1 Clean element 2 Allow engine to warm up prior to operating equipment E...

Страница 21: ...S LISTS AND ASSEMBLY DIAGRAMS IN THIS MANUAL AS A REFERENCE TOOL ONLY NEITHER THE MANUFACTURER OR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED...

Страница 22: ...Plate Assembly 2 47 Handle Tube Front Handle Tube 1 48 Handle Tube Front Handle Tube 1 49 Hex Flange Bolt M6 1 43 50 Right Plate Assembly 2 51 Plug Drain Bolt Plug 2 52 Right Window Assembly 1 Part D...

Страница 23: ...Page 23 For technical questions please call 1 888 866 5797 ITEM 57080 Safety Operation Maintenance Setup Assembly Diagram Generator...

Страница 24: ...Pin 15 20 62 1 46A Connecting Rod Assy 1 47A Hex Flange Bolt M12 1 5 2 Part Description Qty 48A Aluminum Washer 2 49A Crankcase 1 50A Metal Clip 1 51A Oil Alert 1 52A Speed Governor 1 53A Metal Clip 1...

Страница 25: ...Page 25 For technical questions please call 1 888 866 5797 ITEM 57080 Safety Operation Maintenance Setup Assembly Diagram Engine...

Страница 26: ...in addition to the Retail Warranty above In California new equipment that uses small off road engines must be designed built and equipped to meet the State s stringent anti smog standards HFT must war...

Страница 27: ...retail store or by HFT paying for shipping the product for repair 5 Notwithstanding the provisions herein warranty services or repairs must be provided at all retail stores that are franchised to ser...

Страница 28: ...Fuel Cap 3 Fuel Lines for liquid fuel and fuel vapors 4 Fuel Line Fittings 5 Clamps 6 Pressure Relief Valves 7 Control Valves 8 Control Solenoids 9 Electronic Controls 10 Vacuum Control Diaphragms 11...

Отзывы: