Harbor Freight Tools Predator 63966 Скачать руководство пользователя страница 13

Page 13

For technical questions, please call 1-888-866-5797.

ITEM 63966 
        

S

AFETY

S

ETU

p

Op

ERA

TION

M

AINTENANCE

Connecting Electrical Loads

Familiarize yourself with the engine controls, power panel and how to start the engine before using 
the Generator. Calculate the wattage of the products you will use with the Generator and verify 
that the Generator can handle the total load. 

WARNING!  

Connect only properly wired plugs 

to the Generator.  A plug that is spliced onto a 
different cord may be hazardous.  Only a qualified 
electrician should wire a plug onto a cord. 

NOTICE:  

Never exceed the rated capacity for this Generator, 

as serious damage to the Generator and/or appliances, 
tools, and equipment could result from an overload.  Starting 
and running wattage requirements should always be 
calculated when matching this Generator’s wattage capacity to the appliance, tool, or equipment.

Use the DC12 V Receptacle to power 12 VDC equipment.

 

WARNING! 

Do not charge batteries without a proper charge controller.  Do not overcharge.

a.  Connect the items that require the most wattage first.
b.  Connect “inductive” load appliances, tools, and equipment next.  Inductive 

loads are small hand tools and some small appliances.  

c.  Connect any lights next.
d.  Voltage sensitive appliances, tools, and equipment should be the last to be connected to the Generator.  

Plug voltage sensitive items such as TVs, DVD players, microwaves, and cordless telephones into a  
UL

®

 Listed voltage surge protector (not included).  Then, connect the surge protector into the Generator.

IMpORTANT!

  Failure to connect and operate appliances, tools, and equipment in this sequence can cause 

damage to the Generator, appliances, tools, and equipment and will 

void 

the Warranty of this Generator.

Note:  

If Engine speed or voltage fluctuates with a load below the Generator’s 

running watts, move the Choke Lever to the halfway position.

Evenly distributed 

over outlets:

IF ANY CIRCUIT BREAKERS TRIp CHECK THE FOLLOWING:

1.  Make sure that 

ALL circuit breakers

 are reset 

before starting the Generator again.

2.  Adjust the plugs so the loads are  

shared across outlet circuits.

To achieve rated output from the Generator, 
distribute loads over outlets.

St

1,000

400

200 

 

1,200

Tot

al R

unn

ing

 Wa

tts  

 

 

 

 

4,20

0

Lar

ges

t Ad

diti

ona

l St

art-

up 

Wa

tts

1,200

artu

p Wa

tts 

nee

ded

 for

 all

 loa

ds 

 

 

 

 

5,40

0

Must be 

less than 

5,500

Must be 

less than 

6,500

Содержание Predator 63966

Страница 1: ...receipt in a safe and dry place for future reference 18a Using a generator indoors CAN KILL YOU IN MINUTES Generator exhaust contains carbon monoxide This is a poison you cannot see or smell NEVER use inside a home or garage EVEN IF doors and windows are open Only use OUTSIDE and far away from windows doors and vents When unpacking make sure that the product is intact and undamaged If any parts ar...

Страница 2: ...out any precautions that must be taken Access shall be through the use of a special tool or lock and key or other means of security and shall be controlled by the authority responsible for the location 2 Gasoline fuel and fumes are flammable and potentially explosive Use proper fuel storage and handling procedures Do not store fuel or other flammable materials nearby 3 Have multiple ABC class fire...

Страница 3: ...ring use Let engine cool down after use 8 Never store fuel or other flammable materials near the engine 9 Fire Hazard Do not fill gas tank while engine is running Do not operate if gasoline has been spilled Clean spilled gasoline before starting engine Do not operate near pilot light or open flame 10 If the plugged in product operates abnormally or unusually slow immediately stop using the Generat...

Страница 4: ...er piece of equipment 28 Do not operate in explosive atmospheres such as in the presence of flammable liquids gases or dust Gasoline powered engines may ignite the dust or fumes 29 Keep grounded conductive objects such as tools away from exposed live electrical parts and connections to avoid sparking or arcing These events could ignite fumes or vapors 30 Stay alert watch what you are doing and use...

Страница 5: ...adable or missing contact Harbor Freight Tools for a replacement 8 Have the equipment serviced by a qualified repair person using only identical replacement parts This will ensure that the safety of the equipment is maintained Do not attempt any service or maintenance procedures not explained in this manual or any procedures that you are uncertain about your ability to perform safely or correctly ...

Страница 6: ...ded fill level 8 Gallons Engine Oil Type SAE 10W 30 above 32 F 5W 30 at 32 F or below Capacity 1 16 Quart Spark Plug Type NHSP Torch F6TC Gap 0 028 0 031 Valve Clearance Intake 0 004 0 006 Exhaust 0 006 0 008 Run Time 50 load Up to 14 5 hr Available accessories Wheel kit sold separately The emission control system for this Generator s Engine is warranted for standards set by the U S Environmental ...

Страница 7: ...0 volt or 240 volt that is compatible with the electrical characteristics and rated capacities of the tools and equipment being used 3 ON OFF Circuit Breakers The circuit breaker protects the Generator from overloading The rating of the breaker and the load it protects are marked near the breaker Should any of the Circuit Breakers trip the Generator will stop the electricity output If this happens...

Страница 8: ...ssembly Diagram near the end of this manual Grounding The Generator must be properly grounded before use Have the unit grounded by a qualified electrician if you are not qualified to do so To ground the Generator connect a 6 AWG grounding wire not included from the Grounding Terminal on the Control Panel to a grounding rod not included that has been driven at least 24 inches deep into the earth Th...

Страница 9: ...atch any spilled fuel 5 Unthread the screws holding the solenoid in place CAUTION Carburetor bowl may have gas in it which will leak upon removing the solenoid bolt 6 Disconnect the solenoid and solenoid seal from the bolt 7 Unthread the bolt holding the fuel cup 8 Remove the bolt Bolt Seal fuel cup Fuel Cup Seal and Main Jet from the body of the carburetor assembly A carburetor screwdriver not in...

Страница 10: ...ut threading it in and remove it to check the oil level The oil level should be up to the full level as shown above 5 If the oil level is at or below the low mark add the appropriate type of oil until the oil level is at the proper level SAE 10W 30 oil is recommended for general use The SAE Viscosity Grade chart on page 17 in the Service section shows other viscosities to use in different average ...

Страница 11: ... If above test fails do not use receptacle until it is repaired or replaced d Press Reset button in for use RESET TEST RESET TEST Reset Button Test Button 120 Volt GFCI Receptacle 4 Plug in products 5 When finished using the Generator disconnect all electrical loads Note Do not allow Generator to run out of fuel with loads attached 6 Turn off the Engine 7 Allow the Generator and its Engine to comp...

Страница 12: ...ntly until resistance is felt Allow Cable to retract fully and then pull it quickly Repeat until the engine starts Note Do not let the Starter Handle snap back against the engine Hold it as it recoils so it doesn t hit the engine Note If engine does not start check engine oil level Engine will not start with low or no engine oil 5 Allow the Engine to run for several seconds Then if the Choke Lever...

Страница 13: ... Connect inductive load appliances tools and equipment next Inductive loads are small hand tools and some small appliances c Connect any lights next d Voltage sensitive appliances tools and equipment should be the last to be connected to the Generator Plug voltage sensitive items such as TVs DVD players microwaves and cordless telephones into a UL Listed voltage surge protector not included Then c...

Страница 14: ...ge Volts and amps can be multiplied together to get watts volts x amps watts To Calculate Additional Start Up Watts If They Are Not Listed For equipment with a motor Use the rated watts amount as an estimate of additional Start up Watts For most lights or heaters there are no additional start up watts Wattage Estimate Charts Note Wattages listed below are estimates for that type of equipment only ...

Страница 15: ...e engine in an emergency turn the Engine Switch off NOTICE Generator shut off under load may damage the Generator and attached equipment Stopping the Engine Under Normal Conditions 1 Before turning off the Engine turn off all electrical loads then unplug them 2 Turn the Engine Switch off 3 Close the Fuel Valve I O START OFF RESET TEST RESET TEST OFF I O ...

Страница 16: ...a qualified technician service the equipment instead Cleaning Maintenance and Lubrication Note This maintenance schedule is intended solely as a general guide If performance decreases or if equipment operates unusually check systems immediately The maintenance needs of each piece of equipment will differ depending on factors such as duty cycle temperature air quality fuel quality and other factors...

Страница 17: ...lug 4 Remove the drain plug and if possible tilt the crankcase slightly to help drain the oil out Recycle used oil 5 Replace the drain plug and tighten it 6 Clean the top of the Dipstick and the area around it Remove the Dipstick by threading it counterclockwise and wipe it off with a clean lint free rag Full level Full level 7 Add the appropriate type of oil until the oil level is at the full lev...

Страница 18: ... Term Storage When the equipment is to remain idle for longer than 20 days prepare the Engine for storage as follows 1 CLEANING Wait for Engine to cool then clean Engine with dry cloth NOTICE Do not clean using water The water will gradually enter the Engine and cause rust damage Apply a thin coat of rust preventive oil to all metal parts 2 FUEL To protect the fuel tank during storage fill the tan...

Страница 19: ...eral times to air out the chamber Reinstall spark plug and set Choke to START position 9 Replace Fuel Filter IGNITION SPARK RELATED 1 Spark plug cap not connected securely 2 Spark plug electrode wet or dirty 3 Incorrect spark plug gap 4 Spark plug cap broken 5 Circuit breaker tripped electric start models only 6 Incorrect spark timing or faulty ignition system IGNITION SPARK RELATED 1 Connect spar...

Страница 20: ...ded 3 Incorrect spark timing deposit buildup worn engine or other mechanical problems 1 Fill fuel tank with fresh 87 octane stabilizer treated unleaded gasoline Do not use gasoline with more than 10 ethanol E15 E20 E85 etc 2 Do not exceed equipment s load rating 3 Have qualified technician diagnose and service engine Engine backfires 1 Impure or low quality gasoline 2 Engine too cold 3 Intake valv...

Отзывы: