13.  Avoid substantially overloading which will trip 

the circuit breaker. Slightly overloading the 
generator may not trip the circuit breaker, 
but will lead to premature generator failure.

14.  Do not attempt to connect or disconnect 

load connections while standing in water, 
or on wet or soggy ground.

15. 

Do not touch electrically energized parts of 

the generator and interconnecting cables or 
conductors with any part of the body, or with 
any non-insulated conductive object.

16.  Connect the generator only to a load that is 

compatible with the electrical characteristics 
and running wattage of the generator.

17.  Insulate all connections and disconnected wires.
18.  Guard against electric shock.   

Prevent body contact with grounded surfaces such 
as pipes, radiators, ranges, and refrigerators.

19.  Only use a suitable means of transport and 

lifting devices with sufficient weight bearing 
capacity when transporting the generator.

20.  Secure the generator on transport vehicles to 

prevent it from rolling, slipping, and tilting.

21.  Industrial applications must follow 

OSHA requirements.

22.  Do not leave the generator unattended when it is 

running.  Turn off the generator (and remove safety 
keys, if available) before leaving the work area.

23.  The generator can produce high noise levels.  

Prolonged exposure to noise levels 

above 85 dBA is hazardous to hearing. 

Wear ear protection when operating the generator 
or when working nearby while it is operating.

24.  Keep access doors on enclosures locked.
25.  Wear ANSI-approved safety glasses 

and hearing protection during use.

26.  People with pacemakers should consult their 

physician(s) before use.  Electromagnetic fields in 
close proximity to a heart pacemaker could cause 
pacemaker interference or pacemaker failure.  
Caution is necessary when near the 
engine’s magneto or recoil starter.

27.  Use only accessories that are recommended 

by Harbor Freight Tools for your model.  
Accessories that may be suitable for one 

piece of equipment may become hazardous 

when used on another piece of equipment.

28.  Do not operate in explosive atmospheres, 

such as in the presence of flammable 
liquids, gases, or dust.  Gasoline-powered 
engines may ignite the dust or fumes.

29.  Stay alert, watch what you are doing and 

use common sense when operating this 
generator.  Do not use while tired or under the 
influence of drugs, alcohol or medication.

30.  Dress properly.  Do not wear loose clothing or 

jewelry.  Keep hair, clothing and gloves away 
from moving parts.  Loose clothes, jewelry or 
long hair can be caught in moving parts.

31.  Parts, especially exhaust system components, 

get very hot during use.  Stay clear of hot parts.

32.  Do not cover the generator during operation.
33.  Keep the generator and surrounding 

area clean at all times.

34.  Do not smoke, or allow sparks, flames, 

or other sources of ignition around the 
equipment, especially when refuelling.

35.  Use the equipment, accessories, etc., 

in accordance with these instructions and in 
the manner intended for the particular type of 
equipment, taking into account the working 
conditions and the work to be performed.  
Use of the equipment for operations different from 

those intended could result in a hazardous situation.

36.  Do not operate the equipment with known 

leaks in the engine’s fuel system.

37.  When spills of fuel or oil occur, they must be 

cleaned up immediately.  Dispose of fluids and 
cleaning materials as per any local, state, or 
federal codes and regulations.  Store oil rags in 
a bottom-ventilated, covered, metal container.

38.  Keep hands and feet away from moving parts.   

Do not reach over or across 
equipment while operating.

39.  Before use, check for misalignment or binding of 

moving parts, breakage of parts, and any other 
condition that may affect the equipment’s operation.  

if damaged, have the equipment serviced 
before using.

  Many accidents are caused 

by poorly maintained equipment.

40.  Use the correct equipment for the application.  

Do not modify the equipment and do not use the 
equipment for a purpose for which it is not intended.

Operating precautions (continued)

Содержание Predator 63584

Страница 1: ...This is a poison you cannot see or smell NEVER use inside a home or garage EVEN IF doors and windows are open Only use OUTSIDE and far away from windows doors and vents When unpacking make sure that the product is intact and undamaged If any parts are missing or broken please call 1 888 866 5797 as soon as possible Copyright 2017 by Harbor Freight Tools All rights reserved No portion of this manua...

Страница 2: ...orizontal Single Cylinder 4 stroke OHV Cooling System Forced air cooled Fuel Type 87 octane stabilizer treated unleaded gasoline Capacity 2 6 Gallons Engine Oil Type SAE 10W 30 Capacity 20 fl oz Run Time 25 Load with full tank 11 hr Sound Level at 23 feet 25 load 57 dB Bore x Stroke 70mm x 55mm Spark Plug Type F7RTC Torch or equivalent Gap 0 027 0 031 Valve Clearance Intake 0 004 0 006 Exhaust 0 0...

Страница 3: ... of Eye Injury Wear ANSI approved safety goggles with side shields Read the manual before set up and or use Symbol property or Statement WARNING marking concerning Risk of Hearing Loss Wear hearing protection WARNING marking concerning Risk of Respiratory Injury Operate engine OUTSIDE and far away from windows doors and vents WARNING marking concerning Risk of Fire while handling fuel Do not smoke...

Страница 4: ...haust contains carbon monoxide This is a poison you cannot see or smell OFF run STarT LOW OiL OVErLOaD OuTpuT paraLLEL OuTLETS rESET aC 120V rESET DC 12V ESC THrOTTLE OFF run STarT LOW OiL OVErLOaD OuTpuT paraLLEL OuTLETS rESET aC 120V rESET DC 12V ESC THrOTTLE NEVER use inside a home or garage EVEN IF doors and windows are open OFF run STarT LOW OiL OVErLOaD OuTpuT paraLLEL OuTLETS rESET aC 120V ...

Страница 5: ...ded by Harbor Freight Tools for your model Accessories that may be suitable for one piece of equipment may become hazardous when used on another piece of equipment 28 Do not operate in explosive atmospheres such as in the presence of flammable liquids gases or dust Gasoline powered engines may ignite the dust or fumes 29 Stay alert watch what you are doing and use common sense when operating this ...

Страница 6: ...e worn discolored or corroded Keep terminals clean and tight 4 Do not alter or adjust any part of the equipment or its engine that is sealed by the manufacturer or distributor Only a qualified service technician may adjust parts that may increase or decrease governed engine speed 5 Wear ANSI approved safety goggles heavy duty work gloves and dust mask respirator during service 6 Maintain labels an...

Страница 7: ...included from the Grounding Terminal on the Control Panel to a grounding rod not included The grounding rod must be an earth driven copper or brass rod electrode which can adequately ground the Generator 3 Refer to local regulations for ground source information Electric Starter Battery Connection For the electric start function the included 12VDC Battery must be connected before first use 1 Remov...

Страница 8: ...pEraTiOn MainTEnanCE SETup Fuel Cap Battery access Door Control panel Handle Starter Handle Wheel Lock Figure B Generator Front Exhaust Spark plug air Filter Oil Fill access Door Oil Drain Bolt rear Cover Oil Fill Cap access panel Carburetor Figure C Generator rear and interior ...

Страница 9: ...88 866 5797 ITEM 63584 SaFETy OpEraTiOn MainTEnanCE SETup Figure D Display Screen Symbology Symbol Meaning Normal u AC Overvoltage u AC Undervoltage i Generator Output Overcurrent Generator Output Short Circuit Inverter Overheating Maintenance Time ...

Страница 10: ... 10W 30 oil is recommended for general use 6 Thread the Oil Fill Cap Dipstick back in clockwise and replace the Oil Fill Access Door nOTiCE Do not run the engine with too little oil Engine will shut off if engine oil level is too low Oil Fill access Door Full Level xx xx xxx Oil Fill Cap Dipstick Checking and Filling Fuel WarninG TO prEVEnT SEriOuS inJury FrOM FirE Fill the fuel tank in a well ven...

Страница 11: ...ract fully and then pull it quickly Repeat until the Engine starts Do not let the Starter Handle snap back against the housing Hold it as it recoils so it doesn t hit the housing if engine does not start Check engine oil level Engine will not start with low or no engine oil Check spark arrestor cleanliness Engine will not start if spark arrestor is clogged For warm engine turn Combination Switch t...

Страница 12: ...uminates when the Engine starts and the Generator produces power Allow the Engine to run for several seconds then move the Combination Switch slowly to its RUN position note Moving the Combination Switch too fast could stall the Engine iMpOrTanT Allow the Engine to run at no load for five minutes after each start up so that the Engine can stabilize Break in period a Breaking in the Engine will hel...

Страница 13: ... calculated by multiplying volts and amps The resulting number is wattage Never exceed the running wattage for the Generator or any outlet amperage rating Refer to appliance tool owner s manuals to determine the wattage of electrical load devices Long power cords and extension cords draw additional power Keep cord length at a minimum Wattage Estimates Refer to your device documentation for start u...

Страница 14: ... again 5 Restart the Engine and reconnect devices while being careful to not overload Generator Low Oil indicator 1 If the Engine oil level is too low the LOW OIL light turns on and the Engine will automatically shut off 2 The Engine cannot be restarted until the proper amount of oil has been added Add the appropriate type of oil until the oil level is at the proper level SAE 10W 30 oil is recomme...

Страница 15: ...rn the Combination Switch OFF Under normal conditions use the following procedure to shut off the Generator 1 Turn all electrical load devices off and unplug them from the Generator 2 If the Economy ESC Switch is ON turn it to the OFF position 3 Turn the Combination Switch OFF STarT OFF run EMErGEnCy SHuT OFF unplug Loads 1 ESC THrOTTLE On OFF 2 STarT OFF run 3 ...

Страница 16: ... Maintenance and Lubrication Schedule note This maintenance schedule is intended solely as a general guide If performance decreases or if equipment operates unusually check systems immediately The maintenance needs of each piece of equipment will differ depending on factors such as duty cycle temperature air quality fuel quality and other factors note The following procedures are in addition to th...

Страница 17: ...e air Engine Oil Change CauTiOn Oil is very hot during operation and can cause burns Wait for engine to cool before changing oil 1 Make sure the Engine is stopped and is level 2 On the left side of the Generator loosen the Screw and remove the Oil Fill Access Door as shown to the right 3 Lift and tilt the Generator Remove the Drain Plug on the bottom of the machine then set the Generator back down...

Страница 18: ... in lightweight oil briefly then squeeze out the excess oil 4 Install the cleaned filter 5 Secure the Air Filter Cover and replace the Access Panel before use Spark arrestor Maintenance TO prEVEnT SEriOuS inJury anD FirE Operate only with proper spark arrestor installed Operation of this equipment may create sparks that can start fires around dry vegetation a spark arrestor may be required The ope...

Страница 19: ...t spark plug may damage the engine 5 When installing a new spark plug adjust the plug s gap to the specification on the Specifications chart Do not pry against the electrode the spark plug can be damaged 6 Apply anti seize material to Spark Plug threads Install the new spark plug or the cleaned spark plug into the engine Gasket style Finger tighten until the gasket contacts the cylinder head then ...

Страница 20: ...Change engine oil b Clean out area around spark plug Remove spark plug and pour one tablespoon of engine oil into cylinder through spark plug hole c Replace spark plug but leave spark plug cap disconnected d Pull Starter Handle to distribute oil in cylinder Stop after one or two revolutions when you feel the piston start the compression stroke when you start to feel resistance 4 STOraGE arEa Cover...

Страница 21: ...several times to air out the chamber Reinstall spark plug and set Choke to START position 9 Replace Fuel Filter IGNITION SPARK RELATED 1 Spark plug cap not connected securely 2 Spark plug electrode wet or dirty 3 Incorrect spark plug gap 4 Spark plug cap broken 5 Incorrect spark timing or faulty ignition system IGNITION SPARK RELATED 1 Connect spark plug cap properly 2 Clean spark plug 3 Correct s...

Страница 22: ...hanical problems 1 Fill fuel tank with fresh 87 octane stabilizer treated unleaded gasoline Do not use gasoline with more than 10 ethanol E15 E20 E85 etc 2 Do not exceed equipment s load rating 3 Have qualified technician diagnose and service engine Engine backfires 1 Impure or low quality gasoline 2 Engine too cold 3 Intake valve stuck or overheated engine 4 Incorrect timing 1 Fill fuel tank with...