background image

Page 8

For technical questions, please call 1-888-866-5797.

Items 68285 68284 

        

Sa
FE
ty

Op
E

ra
ti

O

n

Maint

E

nanc

E

S

E

tup

tool Set up

tO prEVEnt SEriOuS inJury FrOM acciDEntaL OpEratiOn: 
turn the rotation Switch of the tool to its 

 position and unplug the tool from its 

electrical outlet before assembling or making any adjustments to the tool.

tO prEVEnt SEriOuS inJury: 
DO nOt OpEratE WitH any GuarD DiSaBLED, DaMaGED, Or rEMOVED.   

Wear anSi-approved splash-resistant safety goggles, niOSH-approved dust mask/respirator under 
face shield, and heavy-duty LEatHEr gloves, and other appropriate protective equipment when 
setting up the Drain cleaner. For extra protection from chemicals and bacteria on the appliance and 
in the work area, wear latex, rubber or other liquid barrier gloves under 

the heavy-duty LEatHEr work gloves. Before use, inspect gloves to be sure they are free of defects or 
loose sections that could be caught in the Drain cleaner cable.  rubber soled, non-slip shoes can help 
prevent slipping and electric shock, especially on wet surfaces.

tO prEVEnt SEriOuS inJury FrOM ELEctric SHOcK, tWiStED/BrOKEn caBLES, cHEMicaL BurnS, 
inFEctiOnS anD OtHEr cauSES anD prEVEnt Drain cLEanEr DaMaGE: 
Before each use, inspect Drain cleaner and correct any problems.

1.  Once the Drain Cleaner is assembled, check 

the appliance and Cutting Tools for any signs of 
wear and damage. If necessary, replace worn or 
damaged parts prior to using the Drain Cleaner. 
Dull or damaged Cutting Tools can lead to binding, 
Cable breakage, and slow the drain cleaning.

2.  Verify Drain Cleaner is unplugged and inspect 

the power cord, Ground Fault Circuit Interrupter 
(GFCI) and plug for damage.

 

If the plug has 

been modified, is missing the grounding prong 
or if the cord is damaged, to avoid electrical 
shock, do not use the appliance until the cord 
has been replaced by a qualified electrician.

3.  Clean any oil, grease or dirt from all equipment 

handles and controls.

 

This helps prevent the 

appliance or control from slipping during use.

4.  Verify Foot Switch is attached to Drain Cleaner.

5.  Verify Drain Cleaner is properly assembled. 

Inspect the appliance for broken, worn, missing, 
misaligned or binding parts or any other condition 
which may prevent safe and normal operation.

6.  Make sure that switches and handles move 

smoothly between positions and lock in place.

7.  Rotate the Drum and make sure that 

it turns freely without binding.

8.  Check that all warning labels are present, 

firmly attached and readable. 

9.  Make sure Belt Guard is securely 

fastened to the Drain Cleaner.

10.  Check the Cable for any wear and damage. 

If any section of the Cable is worn or 
flattened, replace Cable before use.

11.  Verify Cable does not have multiple or excessive 

kinks (greater than 15°).  Kinks weaken the Cable 
and can cause Cable failure. Replace any cables 
that have multiple or excessively large kinks.

12.  Look for spaces between the Cable 

coils.  Kinking, stretching (pulling Cable 
by hand) or running the Cable in reverse 
can deform the Cable.  Cables with spaces 
between the coils should be replaced.

13.  Check for signs of excessive corrosion.  

Corrosion weakens the Cable, making it brittle. 
This can be caused by storing the Cable wet 
or using the Cable with corrosive chemicals 
(often found in chemical clog removers). 
Excessively corroded Cable should be replaced.

14.  Before use, fully retract the Cable with 

no more than 2″ of Cable outside of the 

appliance. This will the keep the Cable from 
“whipping” when the appliance is turned on.

15.  Set the Rotation Switch to the 

OFF

 position.

16.  With dry hands, plug cord into properly 

grounded outlet and move the 
Rotation Switch into the 

FOr

 position. 

17.  Move Power-Feed Lever to exactly between 

F

 and 

r

 settings, otherwise Cable will 

start moving in or out during this test.

18.  Press the Foot Switch and note the direction 

of rotation of the Drum. 

if the Foot Switch 

does not control the Drain cleaner’s 
operation, do not use the appliance until 
the Foot Switch has been repaired.

19.  The Drum should rotate clockwise when 

seen from the front of the Drum.  It will match 
the Drum direction arrow on the Drum.  

if 

the rotation is not correct, do not use the 
appliance until it has been repaired.

20.  After inspection, set the Rotation Switch to 

OFF

dry off your hands, and unplug the Drain Cleaner.

21.  Once you’ve verified that the Drain Cleaner is 

in good working order, inspect the work area 
where you will be using the appliance.

Содержание Hydrostar Drain Monster

Страница 1: ...e if product has no number Keep this manual and the receipt in a safe and dry place for future reference 20j When unpacking make sure that the product is intact and undamaged If any parts are missing...

Страница 2: ...the instructions before using the appliance 2 To reduce the risk of injury close supervision is necessary when an appliance is used near children 3 Do not contact moving parts 4 Only use attachments r...

Страница 3: ...ner while you are tired or under the influence of drugs alcohol or medication A moment of inattention while operating may result in serious personal injury 26 Prevent unintentional starting Turn switc...

Страница 4: ...o a 2 pole receptacle as shown in Figure B if a properly grounded outlet is not available Figure B Grounding adapter 5 The temporary adaptor should be used only until a properly grounded outlet can be...

Страница 5: ...Not Included inStaLLatiOn inStructiOnS read the EntirE iMpOrtant SaFEty inFOrMatiOn section at the beginning of this manual including all text under subheadings therein before set up or use of this p...

Страница 6: ...beginning of this manual including all text under subheadings therein before set up or use of this product user Operated controls Rotation Switch Cable Belt Guard Tool Holder item 61856 Belt Guard Kno...

Страница 7: ...ble retrieve a piece to inspect Once you can see the cause of the obstruction select the appropriate tool for the job Run the smallest available tool through the blockage to allow the backed up water...

Страница 8: ...ct the appliance for broken worn missing misaligned or binding parts or any other condition which may prevent safe and normal operation 6 Make sure that switches and handles move smoothly between posi...

Страница 9: ...o be lifted use proper lifting techniques or seek assistance if needed Use caution when moving equipment up and down stairs Wear appropriate footwear to help prevent slipping on floor 12 To prevent Ca...

Страница 10: ...ith one person controlling cable and another person controlling Foot Switch this can cause cable to kink twist or break which can also lead to serious personal injury 3 Make sure Rotation Switch is in...

Страница 11: ...until all the tension is released 3 Place Rotation Switch in OFF position Freeing Lodged cutting tool 1 Release Foot Switch and turn the Rotation Switch to OFF position 2 Pull back on the Cable to fr...

Страница 12: ...Feed Lever are within reach WarninG Only one person should operate the cable feed and the Foot Switch Do not operate the Drain cleaner with one person controlling the cable and another person controll...

Страница 13: ...g The Cable and tool will then need to be retrieved from drain and debris removed retrieving Drain cleaner cable 1 Once drain is clear turn on faucet or use a hose to flush debris out nOtE If water fl...

Страница 14: ...rum WarninG tO prEVEnt SEriOuS inJury Do not attempt to remove a rotating cable cleaning Lubrication 1 The Drain Cleaner should be cleaned as needed with hot soapy water and or disinfectants WarninG r...

Страница 15: ...et 3 3 Cable used is wrong size for drain pipe 4 4 Cable exposed to acid 5 5 Cable worn out 1 1 Do not force cable Let Cutting Tool do the work 2 2 Move Drain Cleaner to within 2 feet of drainpipe inl...

Страница 16: ...DED THE PARTS LIST AND ASSEMBLY DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY NEITHER THE MANUFACTURER OR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS...

Страница 17: ...Page 17 For technical questions please call 1 888 866 5797 Items 68285 68284 SaFEty OpEratiOn MaintEnancE SEtup 68285 assembly Diagram...

Страница 18: ...ption 24 Drum Shaft Retaining Pin 25 Retaining Pin Spring 26 Retaining Pin Screw Set Screw 27 Bolt 28 Tool Holder 29 Bolt 30 Motor 31 Handle 32 Belt Guard Knob 33 V Belt Pulley 34 Bolt 35 V Belt A1118...

Страница 19: ...Page 19 For technical questions please call 1 888 866 5797 Items 68285 68284 SaFEty OpEratiOn MaintEnancE SEtup 68284 assembly Diagram...

Страница 20: ...amages so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS T...