Before start-up, note the following:

The pump must be connected to a GFCI protected plug which has been installed according 
to regulations.  The plug must have a supply voltage of 120 VAC at 60 Hz.

CAUTION

This pump has been evaluated for use with water only.

WARNING

IMPORTANT!  For your own safety – 
before starting to run the pump, please have 
the following items checked by an expert:

1.  Risk of electric shock – This pump is supplied 

with a grounding conductor and grounding-type 
attachment plug.  To reduce the risk of electric shock, 
be certain that it is connected only to a properly 
grounded, grounding-type receptacle.

2.  Risk of electric shock – This pump has not been 

investigated for use in swimming pool areas.

3.  The electrical connections must be 

protected from moisture.

4.  If there is danger of flooding, the electrical 

connections must be taken to higher ground.

5.  Circulation of caustic fluids, as well as the circulation 

of abrasive materials, must be avoided at all costs.

6.  The pump must be protected from frost.

7.  The pump must be protected from running dry.

8.  Access by children should also be 

prevented with appropriate measures.

9. 

 WARNING: To prevent death from electric 

 

shock, pump must be connected only 

 

to a GFCI protected outlet.

10.  Do not use an extension cord with this item.

11.  People with pacemakers should consult their 

physician(s) before use.  Electromagnetic fields in 
close proximity to heart pacemaker could cause 
pacemaker interference or pacemaker failure.

12.  The warnings, precautions, and instructions 

discussed in this instruction manual cannot cover all 
possible conditions and situations that may occur.   
It must be understood by the operator that 
common sense and caution are factors 
which cannot be built into this product, but 
must be supplied by the operator.

Fluid Type

The Pump is designed for use with water with a maximum temperature of 95° F (35°C).  Do not use the pump 
for other fluids, especially not fuels, cleaning fluids, or other chemical products.

Содержание Drummond 57038

Страница 1: ... dry place for future reference 20f When unpacking make sure that the product is intact and undamaged If any parts are missing or broken please call 1 888 866 5797 as soon as possible Copyright 2019 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools ...

Страница 2: ...her ground 5 Circulation of caustic fluids as well as the circulation of abrasive materials must be avoided at all costs 6 The pump must be protected from frost 7 The pump must be protected from running dry 8 Access by children should also be prevented with appropriate measures 9 WARNING To prevent death from electric shock pump must be connected only to a GFCI protected outlet 10 Do not use an ex...

Страница 3: ...se call 1 888 866 5797 Item 57038 Specifications Horsepower 1 8 HP Electrical Rating 120VAC 60Hz 3 3A Power Cord Length 10 Maximum Flow 0 1575 GPH Maximum Head lift 0 Flow 25 Discharge Port 1 NPT Female Operating Water Depth Minimum 3 16 ...

Страница 4: ...ed only to a GFCI protected outlet WARNING TO PREVENT SERIOUS INJURY If the power cord or plug is damaged do not use the pump The power cord or plug may only be repaired by a certified electrician Areas of use 1 This pump is designed to pump clean water only 2 This pump is designed to be used for Removing water from flooded basements window wells garages flat roofs 3 This pump should NOT be used f...

Страница 5: ...otected outlet before use e Verify that water and moisture cannot get near the power supply socket f Verify that the Pump is installed so as to prevent it from running dry 2 After the Pump and discharge hose are placed connect the Power Cord into a 120 VAC 60Hz GFCI protected outlet Be sure the power cord reaches the outlet without any strain to the cord Discharge Hose 120 VAC 60Hz GFCI protected ...

Страница 6: ...oting Problem Possible Causes Possible Solutions Pump runs but will not deliver any water 1 Inlet Screen and or Impeller clogged 2 When starting the water height falls below the minimum level 3 16 3 Low line voltage 4 Check Valve sold separately stuck or installed backwards 1 Remove Base Clean dirt and debris from inlet screen and Impeller then reinstall Base 2 The water must be at least 3 16 deep...

Страница 7: ...HE MANUFACTURER AND OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS AND NOT BY THE BUYER THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO Parts List and Diagram Part D...

Страница 8: ...damages so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS To take advantage of this warranty the product or part must be returned to us with transportation charges prepaid Proof of purchase date and an explanation of the complaint must accompany the merchand...