For technical questions, please call 1-888-866-5797.

Item 56701 

        

Pump 

Cord

Float 

Switch 

Cord

Sewage Cover

Vent

Float 

Switch

Pump

Figure B:  Pump Position

4.  Attach a discharge pipe to the Pump Outlet.

Note:

 Wrap all threaded connections 

with PTFE thread seal tape.

5.  Check Valve is sold separately. Install 

according to manufacturer instructions.

6.  To prevent excessive cycling from backflow of water, 

install a check valve onto the discharge pipe.  This 
prevents water from flowing back after the pump 
shuts off.  Mount the check valve according to check 
valve label to avoid the valve flapper getting stuck.

To main waste line  

(sewer or septic tank)

GFCI-

Protected 

Receptacle

Float 

Switch 

Cord

Pump Cord

Vent

Check 

Valve

Pump 

Outlet

1

/

8

 Air 

Bleed 

Hole

Discharge 

Pipe

Figure C:  Outlet Pipe and Plug

IMPORTANT:

  Drill a 

1

/

8

 diameter air bleed hole 

through the Discharge Pipe just above the lower Base 

to prevent Pump ″airlock″.  A small spray of water out 

of this hole is normal while the Pump is running.

7.  Connect additional Discharge Pipe as needed to 

direct the discharge to the main waste line for the 
sewer or septic tank.  The discharge should be kept 
as short as possible with a minimum number of turns.

IMPORTANT:  Do not exceed the 
Maximum Head Lift @ 0 Flow of the Pump.

Operation

After reading these instructions, consider the following points before starting the pump:

1.  Verify that the pump rests on the floor of the basin.

2.  Verify that the discharge pipe is properly connected.

3.  Verify that the electrical connection 

is 120 VAC, 60 Hz.

4.  Verify that the electrical socket is GFCI 

protected and in good condition. Test 
GFCI protected outlet before use.

5.  Verify that water and moisture cannot 

get near the power supply socket.

6.  Verify that the pump is installed so 

as to prevent running dry.

Maintenance

TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION: 
Unplug the Pump from its electrical outlet before performing any 
inspection, maintenance, or cleaning procedures.

If the pump is moved during operation, flush it out with clean water after every use.

Содержание DRUMMOND 56701

Страница 1: ...eipt in a safe and dry place for future reference 19f When unpacking make sure that the product is intact and undamaged If any parts are missing or broken please call 1 888 866 5797 as soon as possible Copyright 2019 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Har...

Страница 2: ... If there is danger of flooding the electrical connections must be taken to higher ground 5 Circulation of caustic fluids as well as the circulation of abrasive materials must be avoided at all costs 6 The pump must be protected from frost 7 The pump must be protected from running dry 8 Access by children should also be prevented with appropriate measures 9 To prevent death from electric shock pum...

Страница 3: ...revent death from electric shock pump must be connected only to a GFCI protected outlet WARNING If the power cord or plug is damaged do not use the pump The power cord or plug may only be repaired by a certified electrician Areas of use 1 This pump is designed to be used for Pumping domestic sewage effluent wastewater groundwater and other nonexplosive noncorrosive liquids with up to 2 diameter so...

Страница 4: ...all spray of water out of this hole is normal while the Pump is running 7 Connect additional Discharge Pipe as needed to direct the discharge to the main waste line for the sewer or septic tank The discharge should be kept as short as possible with a minimum number of turns IMPORTANT Do not exceed the Maximum Head Lift 0 Flow of the Pump Operation After reading these instructions consider the foll...

Страница 5: ...d examine check valve Pump won t start or run 1 Check power connections and circuits fuses 2 Float Switch failed 3 Impeller clogged 4 Defective motor 1 Consult an electrician 2 Replace Float Switch 3 Clean out dirt and debris from impeller 4 Have a qualified service technician repair or replace Excessive noise or vibration 1 Worn bearings 2 Debris in impeller 3 Discharge pipe restricted 1 Have a q...

Страница 6: ...ARTS THERETO OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO Parts List Part Description Qty 1 Cross Flange Screw 2 2 Power Cord 1 2 1 Sheathing Block 1 3 Pin Insertion 1 3 1 Insert 3 4 Ring 1 5 Sealing Bolt 1 6 O Ring 1 7 Cross Flange Screw 6 8 Spring Washer 10 9 Cross Flange Screw 1 10 Clamp 1 11 Cable Sheath 1 12 Upper Pump Cover 1 13 Screw Assembly 2 14 Capacitor 1 15 Gr...

Страница 7: ...Page 7 For technical questions please call 1 888 866 5797 Item 56701 Assembly Diagram ...

Страница 8: ...damages so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS To take advantage of this warranty the product or part must be returned to us with transportation charges prepaid Proof of purchase date and an explanation of the complaint must accompany the merchand...

Отзывы: