manualshive.com logo in svg
background image

Page 4

For technical questions, please call 1-888-866-5797.

Item 60801 60802 

        

Sa
FE
ty

Op
E

ra
ti

O

n

Maint

E

nanc

E

S

E

tup

air Source

1. 

 

never connect to an air source  

 

that is capable of exceeding  

 

200 psi.

  Over pressurizing the  

 

tool may cause bursting, abnormal  

 

operation, breakage of the tool or 

serious injury to persons.  Use only clean, dry, 
regulated compressed air at the rated pressure 
or within the rated pressure range as marked on 
the tool.  Always verify prior to using the tool that 
the air source has been adjusted to the rated air 
pressure or within the rated air-pressure range.

2. 

Never use oxygen, carbon dioxide, combustible 
gases or any bottled gas as an air source 
for the tool.

  Such gases are capable of 

explosion and serious injury to persons.

 SaVE tHESE inStructiOnS.

SyMBOLS anD SpEciFic SaFEty inStructiOnS

Symbol Definitions

Symbol

property or statement

pSi

Pounds per square inch of pressure

cFM

Cubic Feet per Minute flow

ScFM

Cubic Feet per Minute flow 
at standard conditions

npt

National pipe thread, tapered

npS

National pipe thread, straight

Symbol

property or statement

WARNING marking 
concerning Risk of Eye Injury.  
Wear ANSI-approved eye protection.

WARNING marking concerning Risk of 
Hearing Loss.  Wear hearing protection.

WARNING marking concerning 
Risk of Respiratory Injury.  Wear 
NIOSH-approved dust mask/respirator.

WARNING marking concerning 
Risk of Explosion.

Specific Safety instructions

1.  The warnings and precautions discussed in this 

manual cannot cover all possible conditions and 
situations that may occur.  It must be understood 
by the operator that common sense and caution 
are factors which cannot be built into this 
product, but must be supplied by the operator.

2. 

DO nOt DrOp tanK, riSK OF EXpLOSiOn.

3.  Attach all accessories properly to the Soda Blaster 

before connecting the air supply.  A loose 
accessory may detach or break during operation.

4.  Obey the manual for the air compressor 

used to power this Soda Blaster.

5.  Install an in-line shutoff valve to allow 

immediate control over the air supply in an 
emergency, even if a hose is ruptured.

Содержание CentralPneumatic 60801

Страница 1: ...rence 21b When unpacking make sure that the product is intact and undamaged If any parts are missing or broken please call 1 888 866 5797 as soon as possible Copyright 2021 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools Diagrams within this manua...

Страница 2: ...ult in minor or moderate injury Addresses practices not related to personal injury iMpOrtant SaFEty inStructiOnS inStructiOnS pErtaininG tO a riSK OF FirE ELEctric SHOcK Or inJury tO pErSOnS WarninG When using tools basic precautions should always be followed including the following General to reduce the risks of electric shock fire and injury to persons read all the instructions before using the ...

Страница 3: ... is able to lead to loss of control 2 Do not force the tool Use the correct tool for the application The correct tool will do the job better and safer at the rate for which the tool is designed 3 Do not use the tool if the switch does not turn the tool on or off Any tool that cannot be controlled with the switch is dangerous and must be repaired 4 Disconnect the tool from the air source before mak...

Страница 4: ...M Cubic Feet per Minute flow at standard conditions npt National pipe thread tapered npS National pipe thread straight Symbol property or statement WARNING marking concerning Risk of Eye Injury Wear ANSI approved eye protection WARNING marking concerning Risk of Hearing Loss Wear hearing protection WARNING marking concerning Risk of Respiratory Injury Wear NIOSH approved dust mask respirator WARNI...

Страница 5: ...controls cannot keep silica exposures below the NIOSH REL 7 Provide periodic medical examinations for all workers who may be exposed to crystalline silica 8 Post signs to warn workers about the hazard and to inform them about required protective equipment 9 Provide workers with training that includes information about health effects work practices and protective equipment for crystalline silica 10...

Страница 6: ... Specifications itEM 60801 60802 Maximum Air Pressure 90 PSI Air Inlet 1 4 18 NPT Average Air Consumption 8 5 CFM 90 PSI 7 CFM 90 PSI Abrasive Capacity 40 lb 15 lb Abrasive Type Sodium Bicarbonate media only components and controls tank air Valve air regulator Knob Media regulator Knob Media Valve Safety Valve pressure Gauge nozzle ...

Страница 7: ... pressure gauge dryer in line shutoff valve and quick coupler for best service an in line shutoff ball valve is an important safety device because it controls the air supply even if the air hose is ruptured the shutoff valve should be a ball valve because it can be closed quickly note An oiler system should not be used with this Soda Blaster The oil will mix with the material being propelled causi...

Страница 8: ...avoid clogging the Soda Blaster note The Nozzle size depends on grit of media used Change the nozzle as needed to suit the abrasive 1 Pull back on the blue Air Hose Connector 8 collar and pull out Air Hose 15 2 Hold collar on Tank 1 with a wrench and use another wrench to loosen Bushing 10 Wrenches not included 3 Remove entire media discharge assembly slowly being careful with the Pickup Tube 11 a...

Страница 9: ...al moving the Nozzle from side to side nOtE The flow rate of the media may be irregular when first started Provided the media is dry the flow rate will normalize in approximately one minute 5 Use Media Regulator Knob to adjust the media flow rate 6 Adjust the Air Regulator to adjust the air flow and pressure Do not set the pressure higher than 90 PSI 7 If the Soda Blaster requires more force to ac...

Страница 10: ...regular operation of the air operated Soda Blaster 1 BEFOrE EacH uSE inspect the general condition of the Soda Blaster Check for loose hardware or housing misalignment or binding of moving parts cracked or broken parts and any other condition that may affect its safe operation 2 Daily air Supply Maintenance Every day maintain the air supply according to the component manufacturers instructions Dra...

Страница 11: ... LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO record product s Serial number Here note If product has no serial number record month and year of purchase instead note Some parts are listed and shown for illustration purposes only and are not available individually as replacemen...

Страница 12: ...damages so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS To take advantage of this warranty the product or part must be returned to us with transportation charges prepaid Proof of purchase date and an explanation of the complaint must accompany the merchand...

Отзывы: