background image

SKU 40400

For technical questions, please call 1-800-444-3353.

Page 3

Safety Warnings (continued)

7.

Dress properly

.  Do not wear loose clothing or jewelry as they can be caught in moving parts.

Protective, electrically non-conductive clothes and non-skid footwear are recommended when working.
Wear restrictive hair covering to contain long hair.

8.

Use eye and ear protection

.  Always wear ANSI approved impact safety goggles. Wear an ANSI

approved dust mask or respirator when working around metal, wood, and chemical dusts and mists.

9.

Do not overreach

.  Keep proper footing and balance at all times. Do not reach over or across running

machines.

10.

Maintain tools with care

.  Keep tools sharp and clean for better and safer performance. Follow

instructions for lubricating and changing accessories. Inspect tool cords periodically and, if damaged,
have them repaired by an authorized technician. The handles must be kept clean, dry, and free from oil
and grease at all times.

11.

Disconnect power

. Unplug tool when not in use.

12.

Remove adjusting keys and wrenches

.  Check that keys and adjusting wrenches are removed from

the tool or machine work surface before plugging it in.

13.

Avoid unintentional starting

.  Be sure the switch is in the Off position when not in use and before

plugging in.

14.

Stay alert

.  Watch what you are doing, use common sense. Do not operate any tool when you are tired.

15.

Check for damaged parts

.  Before using any tool, any part that appears damaged should be carefully

checked to determine that it will operate properly and perform its intended function. Check for
alignment and binding of moving parts; any broken parts or mounting fixtures; and any other condition
that may affect proper operation. Any part that is damaged should be properly repaired or replaced by
a qualified technician. Do not use the tool if any switch does not turn On and Off properly.

16.

Guard against electric shock

.  Prevent body contact with grounded surfaces such as pipes, radiators,

ranges, and refrigerator enclosures.

17.

Replacement parts and accessories

.  When servicing, use only identical replacement parts. Use of

any other parts will void the warranty. Only use accessories intended for use with this tool. Approved
accessories are available from Harbor Freight Tools.

18.

Do not operate tool if under the influence of alcohol or drugs

.  Read warning labels on

prescriptions to determine if your judgment or reflexes are impaired while taking drugs. If there is any
doubt, do not operate the tool.

19.

Use proper size and type extension cord

. If an extension cord is required, it must be of the proper

size and type to supply the correct current to the tool without heating up. Otherwise, the extension cord
could melt and catch fire, or cause electrical damage to the tool. This tool requires use of an extension
cord of 

0 to 15 amps 

capability (up to 50 feet), with wire size rated at 

16 AWG

. Longer extension cords

require larger size wire. If you are using the tool outdoors, use an extension cord rated for outdoor use
(signified by “WA” on the jacket).

20.

Maintenance

.  For your safety, service and maintenance should be performed regularly by a qualified

technician.

21.

Drain compressor every day.

  Do not allow moisture to build up inside the compressor.

22.

Make sure all equipment is rated to the appropriate capacity.

23.

Avoid explosions and fire

. Never place flammable objects near the compressor. Never spray water or

any flammable liquids towards the compressor.

Содержание Central Pneumatic 40400

Страница 1: ...product described herein 3491 Mission Oaks Blvd Camarillo CA 93011 Visit our Web site at http www harborfreight com Copyright 1999 by Harbor Freight Tools All rights reserved No portion of this manua...

Страница 2: ...tood by the operator that COMMON SENSE AND CAUTION ARE FACTORS WHICH CANNOT BE BUILT INTOTHIS PRODUCT BUT MUST BE SUPPLIED BY THE OPERATOR Safety Warnings Read all safety warnings before using this to...

Страница 3: ...parts or mounting fixtures and any other condition that may affect proper operation Any part that is damaged should be properly repaired or replaced by a qualified technician Do not use the tool if a...

Страница 4: ...e a good quality 30 weight non detergent compressor oil Change the oil after every 500 hours of operation 1 By checking the level of fluid in the Oil Sight part 20 you will be able to determine the oi...

Страница 5: ...wing 1 Push down on the ON OFF switch to turn the compressor off 2 Unscrew the Petcock 53 two to three turns 3 When all pressure is released close the Petcock 53 again Warning To reduce the risk of fi...

Страница 6: ...OR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OFTHE PRODUCT IN FAC...

Страница 7: ...a V n i a r D 1 4 1 r e n i a t e R l i O 1 4 4 e v l a V d e t a l u g e R 1 5 1 d o R g n i t c e n n o C 1 5 4 t e l t u O 1 6 1 e s a c k n a r C t e k s a G 1 6 4 h c t i w S e r u s s e r P r i...

Страница 8: ...SKU 40400 For technical questions please call 1 800 444 3353 Page 8 Assembly Diagram REV 01 06...

Отзывы: