DC Voltage Measurements

Measure DC conductors carrying up to 250 VDC.

1. 

Turn the Range Selector Switch 
to 250 DCV setting.

2. 

Follow the directions above under 
“AC Voltage Measurements”, only 
use the DC settings instead.

DC Current Measurements

Measure DC conductors carrying up to 5 amperes.

1. 

Turn the Range Selector Switch 
to the 5A position.

2. 

Always start with the highest range 
if the amperage is unknown.

3. 

Plug the red lead into the 5ADC (Top) 

Jack. Plug the black lead into the COM 
(Bottom) Jack.  Switch the Multimeter ON.

4. 

Carefully touch the exposed 
conductors with the tips of the probes 
to measure the amperage.

Note:

 Amperage is always tested in 

series with the circuit under test.

5. 

Read measurement. 

6. 

If the reading is less than .2 AMPs, 

switch the red lead to the VΩmA (Center) 
Jack and set the Range Selector 

Switch to the 200 mA setting.

7. 

When testing is complete, remove Test 
Leads and store with multimeter.

Resistance Measurements

Measure circuit resistance up to 2000K Ohms.

1. 

Warning: Never measure resistance on a 
circuit with voltage running through it.

2. 

Turn the Range Selector Switch 

to the 200 Ω position.

3. 

Plug the red Test Lead into the 

VΩmA (Center) Jack. Plug the black 

Test Lead into the Com (Bottom) 

Jack.  Switch the Multimeter ON.

4. 

Short the Test Leads together. The 
meter should read “0” Ohms. 

5. 

Touch the exposed conductors 
with the tips of the Test Leads.

6. 

Read measurement.

7. 

If the reading is “1”, set the Range Selector 

Switch to the next higher Ohm (Ω) position.

Transistor (hFE) Measurements

Test transistors to ensure proper function.

1. 

Turn the Range Selector Switch 
to the hFE position.  

2. 

Switch the Multimeter ON.

3. 

Insert the transistor pins into the appropriate 
hFE jack (NPN or PNP) according to the 
EBC (Emitter, Base, Collector) sequence.

4. 

The meter will show the 
approximate hFE value.

Содержание 7 function

Страница 1: ...rence 17f When unpacking make sure that the product is intact and undamaged If any parts are missing or broken please call 1 888 866 5797 as soon as possible Copyright 2017 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools Diagrams within this manua...

Страница 2: ...Frequency 45 to 450 Hz DC Amps Ranges 200mA 2000mA 20mA 5A Accuracy 0mA 200mA 1 2 2D 5A 3 2D DC Voltage Ranges 200mV 2000mV 20 200 250V Accuracy 200mV 0 5 1D 2000mV 200V 1 2D 250V 1 2D AC Voltage Ranges 200 250V Accuracy 45 450 Hz 1 2 10D Resistance Ranges 200 2000 20K 200K 2000K Ohm WARNING SYMBOLS AND DEFINITIONS ...

Страница 3: ...necting the meter in series when measuring current 7 Connect the common COM test lead first and disconnect it last 8 Hold the probes with fingers behind guards 9 Avoid electrical shock Use extreme caution when working near uninsulated conductors or bus bars Prevent body contact with grounded surfaces such as pipes radiators ranges and cabinet enclosures when testing voltages 10 Observe work area c...

Страница 4: ... voltage to the Test Leads when the Multimeter is in the Ohms testing setting Damage can occur to the multimeter 27 Do not switch between testing modes with the multimeter connected to a circuit 28 Never attempt to use the meter at a setting combination marked as blank on the scale 29 Prior to testing capacitors resistance diodes or continuity disconnect all power to the circuit and discharge all ...

Страница 5: ...nd VΩmA Center Jacks and the Multimeter is in an Ohms testing setting Damage can occur to the multimeter or the fuse may blow 3 Do not switch between testing modes with the multimeter connected to a circuit AC Voltage Measurements Measure AC conductors carrying up to 250 VAC 45 450 Hz 1 Turn the Range Selector Switch to 250 ACV setting Always start with the highest range if the voltage is unknown ...

Страница 6: ...the VΩmA Center Jack and set the Range Selector Switch to the 200 mA setting 7 When testing is complete remove Test Leads and store with multimeter Resistance Measurements Measure circuit resistance up to 2000K Ohms 1 Warning Never measure resistance on a circuit with voltage running through it 2 Turn the Range Selector Switch to the 200 Ω position 3 Plug the red Test Lead into the VΩmA Center Jac...

Страница 7: ...lack Test Lead into the Com Bottom Jack Switch the Multimeter ON 3 Connect the red probe to the positive terminal of the battery and the black to the negative terminal 4 The battery amperage under a load of 370 mW will be displayed to a resolution of 1mA 5 Normal amperage For a standard 9V 6LR61 battery 25 mA 6 For a 1 5 V AA LR6 battery 4 mA 7 To prevent accidents turn off the tool and disconnect...

Страница 8: ...perty or for incidental contingent special or consequential damages arising from the use of our product Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS To take adva...

Отзывы: