Harbor Freight Tools 66163 Скачать руководство пользователя страница 7

SKU 66163 

For technical questions, please call 1-800-444-3353. 

Page 7

pLEASE READ ThE 

FOLLOWing CAREFULLY

THE  MAnufACTuRER  AnD/oR  DisTRibuToR 

HAS PROVIDED THE PARTS LIST AND ASSEMBLy 

DIAGRAM  IN  THIS  MANUAL AS A  REFERENCE 

TOOL ONLy.  NEITHER THE MANUFACTURER OR 

DISTRIBUTOR  MAKES  ANy  REPRESENTATION 

OR  WARRANTy  OF ANy  KIND TO THE  BUyER 

THAT HE OR SHE IS QUALIFIED TO MAKE ANy 

REPAIRS  TO  THE  PRODUCT,  OR  THAT  HE  OR 

SHE IS QUALIFIED TO REPLACE ANy PARTS OF 

THE PRODUCT.  IN FACT, THE MANUFACTURER 

AnD/oR  DisTRibuToR  ExPREssly  sTATEs 

THAT ALL REPAIRS AND PARTS REPLACEMENTS 

SHOULD BE UNDERTAKEN By CERTIFIED AND 

LICENSED  TECHNICIANS,  AND  NOT  By  THE 

BUyER.  THE BUyER ASSUMES ALL RISK AND 

LIABILITy ARISING OUT OF HIS OR HER REPAIRS 

TO THE ORIGINAL PRODUCT OR REPLACEMENT 

PARTS THERETO, OR ARISING OUT OF HIS OR 

HER INSTALLATION OF REPLACEMENT PARTS 
THERETO.

problem

possible Cause

possible Solution

Auto Vacuum does not turn on.

No input power.

1. 

Vehicle’s battery low.

2. 

Blown fuse.

3. 

Make sure 12 Volt Power Plug is 

1. 

properly connected to vehicle’s 12 volt 

cigarette lighter outlet.
Make sure vehicle’s battery is fully 

2. 

charged.
Replace the fuse.

3. 

Low or no suction.

Clogged Container and/or nozzle 

1. 

openings.
Container full.

2. 

filter and/or impeller area clogged.

3. 

Clean out Container and/or nozzle 

1. 

openings.
Empty Container.

2. 

Clean out filter and/or impeller area.

3. 

TROUBLEShOOTing

Record product’s Serial number here: 
note:

  If product has no serial number, record month and year of purchase instead.

note:

  Some parts are listed and shown for illustration purposes only, and are not avail-

able individually as replacement parts.

Cleaning, Maintenance, and 

Lubrication

BEFORE EACH USE, inspect the 

1. 

general condition of the Auto Vac-

uum.  Check for misalignment or 

binding of moving parts, cracked or 

broken parts, damaged electrical wir-

ing, and any other condition that may 

affect its safe operation.
AFTER USE,

2. 

 clean the external 

surfaces of the tool with a clean cloth.  

Refer to previous instructions for 

cleaning the Container (2), Filter Sup-

port (8), Filter (9), and Impeller area.

3. 

WARNING!  If the 12 Volt Power 

Cord/Plug (11) of this Auto Vacuum is 

damaged, it must be replaced only by 

a qualified service technician.

Содержание 66163

Страница 1: ...reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools Diagrams within this manual may not be drawn proportionally Due to continuing improvements actual product may differ slightly from the product described herein Tools required for assembly and service may not be included For technical ...

Страница 2: ...ol indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE is used to address practices not related to personal injury CAUTION without the safety alert symbol is used to address practices not related to personal injury General Safety Warnings WARNING Read all safety warnings and instructions Failure to follow the warnings and instructions may result in ...

Страница 3: ...tool Carrying power tools with your finger on the Power Switch or energizing power tools that have the Power Switch on invites accidents Do not overreach Keep proper d footing and balance at all times This enables better control of the power tool in unexpected situations Dress properly Do not wear loose e clothing or jewelry Keep your hair clothing and gloves away from moving parts Loose clothes j...

Страница 4: ...s Maintain labels and nameplates 2 on the Auto Vacuum These carry important safety information If un readable or missing contact Harbor Freight Tools for a replacement Avoid unintentional starting 3 Pre pare to begin work before turning on the Auto Vacuum Do not leave the tool unattended 4 when it is plugged into a vehicle s cigarette lighter accessories out let Turn off the tool and unplug it fro...

Страница 5: ...o the tool Note For additional information regarding the parts listed in the following pages refer to the Assembly Diagram near the end of this manual To pick up 1 solids attach either the Long Nozzle 6 or the short Nozzle 10 to the Collector 2 as follows a To attach the sort Nozzle 1 push the short end of the Nozzle into the opening at the front end of the Col lector making sure that the deflec t...

Страница 6: ...Reassemble the Auto Vacuum and e store it in a clean dry safe location out of reach of children and other unauthorized persons See Figure B Maintenance And Servicing Procedures not specifically explained in this manual must be performed only by a qualified technician To prevent serious injury from accidental operation Turn the Power Switch 5 of the Auto Vacuum to its OFF position and unplug the to...

Страница 7: ...operly connected to vehicle s 12 volt cigarette lighter outlet Make sure vehicle s battery is fully 2 charged Replace the fuse 3 Low or no suction Clogged Container and or Nozzle 1 openings Container full 2 Filter and or Impeller area clogged 3 Clean out Container and or Nozzle 1 openings Empty Container 2 Clean out Filter and or Impeller area 3 TROUBLESHOOTING Record Product s Serial Number Here ...

Страница 8: ...AGRAM Part Description Qty Part Description Qty 1 Motor 1 7 Liquid Pick Up Nozzle 1 2 Collector 1 8 Filter Support 1 3 Container Release Button 1 9 Filter 1 4 Power On Light 1 10 Small Crevise Nozzle 1 5 Power Switch 1 11 12 Volt Power Plug 1 6 Large Crevise Nozzle 1 1 2 3 4 5 6 7 10 11 8 9 ...