14
PART
DESCRIPTION
PART #
F
Blade Bracket
104000-0318FL
G
Blade
108001-4043BK
M
Glass Bowl
991300-0547TR
Printed in China
WARRANTY
F
G
M
Harbor Breeze®
trademark of LF, LLC.
All rights reserved.
Lowes.com/harborbreeze
TROUBLE SHOOTING
Lowes.com/harborbreeze
15
CARE AND MAINTENANCE
registered
• To reduce the risk of fire, electric shock or injury to persons, care and maintain this fan.
•
IMPORTANT:
Shut off main power supply before beginning any maintenance.
• DO NOT use water or detergents when cleaning the fan or fan blades. A dry dust cloth or lightly
dampened cloth will be suitable for most cleaning.
• Clean fan housing with only a soft brush or lint-free cloth to avoid scratching the finish. Clean blades
with a lint-free cloth. You may occasionally apply a light coat of furniture polish to blades for added
protection.
• At least twice each year, tighten all screws and lower canopy to check mounting bracket screws and
downrod assembly.
• Bulb Replacement: Use three 40-watt max. G9 halogen bulbs only; CFLs and LEDs are not
recommended for this item.
The manufacturer warrants this fan to be free from defects in workmanship and material present at
time of shipment from the factory for lifetime limited from the date of purchase. This warranty applies
only to the original purchaser. The manufacturer agrees to correct such defect at no charge or at our
option replace the ceiling fan with a comparable or superior model.
To obtain warranty service, present a copy of your sales receipt as proof of purchase. All cost of
removal and reinstallation are the expressed responsibility of the purchaser. Any damage to the
ceiling fan by accident, misuse or improper installation, or by affixing accessories not produced by
the manufacturer of the fan, are at the purchaser’s own responsibility. The manufacturer assumes no
responsibility whatsoever for fan installation during the lifetime limited warranty. Any service
performed by an unauthorized person will render the warranty invalid.
Due to varying climatic conditions, this warranty does not cover changes in brass finish, rusting,
pitting, tarnishing, corroding or peeling. Brass finish fans maintain their beauty when protected from
varying weather conditions. Any glass provided with this fan is not covered by the warranty. Any
replacement of defective parts for the ceiling fan must be reported within the first year from the date
of purchase. For the balance of the warranty, call our customer service department at
1-800-643-0067 for return authorization and shipping instructions so that we may repair or replace
the ceiling fan. Any fan or parts returned improperly packaged is the sole responsibility of the
purchaser. There is no further expressed warranty. The manufacturer disclaims any and all implied
warranties.
The duration of any implied warranty which can not be disclaimed is limited to the lifetime limited
period as specified in our warranty. The manufacturer shall not be liable for incidental, consequential
or special damages arising at or in connection with product use or performance except as may
otherwise be accorded by law. This warranty gives you specific legal rights and you also have other
rights which vary from state to state. This warranty supersedes all prior warranties.
Note
: A small amount of “wobble” is normal and should not be considered a defect.
REPLACEMENT PARTS LIST
For replacement parts, call our customer service department at 1-800-643-0067, 8 a.m. - 6 p.m.,
EST, Monday - Thursday, 8 a.m. - 5 p.m., EST, Friday.
1. Chain switch is “off”.
2. Faulty wire connection.
3. Reverse switch not engaged.
1. Pull chain switch.
2. Turn power off. Loosen canopy;
check all connections.
3. Push switch firmly either way.
Noisy operation.
1. Blades are loose.
2. Cracked blade
3. Unapproved speed control.
1. Tighten all blade screws.
2. Replace blades (call customer
service).
3. Replace with an approved speed
control device.
PROBLEM
POSSIBLE CAUSE
CORRECTIVE ACTION
Excessive wobbling. 1. Blades are loose.
2. Blade brackets incorrectly
attached.
3. Unbalanced blades.
4. Fan not securely mounted.
5. Fan too close to vaulted ceiling.
1. Tighten all blade screws.
2. Reinstall blade brackets.
3. Use blade balancing kit included.
4. Turn power off. Carefully loosen
canopy and remount securely.
5. Lower fan or move it to another
location.
Fan blades do not