background image

5

HARDWARE CONTENTS 

(shown actual size)

 

Fiber

Blade

Washer

Qty. 15  

BB

CC

AA

Blade

Screw

Qty. 15

E3 Wire

Connector

Qty. 4 

 

Before beginning assembly and installation of product, make sure all parts are present. Compare  

 

 

parts with package contents list and hardware contents above. If any part is missing or  

 

 

damaged, do not attempt to assemble the product. Contact customer service for replacement parts. 

Estimated Assembly Time:

 

120

 

minutes

Tools Required for Assembly (not included):

 

Electrical Tape, Phillips Screwdriver, Pliers, Safety 

Glasses, Stepladder and Wire Strippers

Helpful Tools (not included):

 

AC Tester Light, Tape Measure, Do-It-Yourself-Wiring Handbook

 

(available at Lowe’s)

 and Wire Cutters

Bulbs Required (included): 3 candelabra base 60-watt max. bulbs

       
       

DANGER

When using an existing outlet box, make sure the outlet box is securely attached to 

the building structure and can support the full weight of the fan. Failure to do this can result in serious 
injury or death.

 The stability of the outlet box is essential in minimizing wobble and noise in the fan 

after installation is complete. 

      

CAUTION

: Be sure outlet box is properly grounded and that a ground wire (green or bare) is 

present.

After opening top of carton, remove mounting hardware package from foam inserts. Remove motor 
from packing and place on carpet or on foam to avoid damage to finish.

      

CAUTION

: Carefully check all screws, bolts and nuts on fan motor assembly to ensure that they 

are secured.

PREPARATION

 

Содержание CHESHIRE II

Страница 1: ...arts Before returning to your retailer call our customer service department at 1 800 527 1292 8 30 a m 5 p m CST Monday Friday Federal regulations require ceiling fans with light kits manufactured or...

Страница 2: ...on or foam inserts Should this fan need to be returned to the factory for repairs it must be shipped in its original packaging to ensure proper protection against damage that might exceed the initial...

Страница 3: ...arp edges To reduce the risk of fire electrical shock or personal injury wire connectors provided with this fan are designed to accept only one 12 gauge house wire and two lead wires from the fan If y...

Страница 4: ...Motor Housing Mounting 4 Screw preassembled O Motor Screw 10 preassembled P 5 4 M M Lock Washer 10 preassembled Q Vice preassembled 1 PART DESCRIPTION QUANTITY A Motor Housing 1 B Mounting Bracket 1...

Страница 5: ...self Wiring Handbook available at Lowe s and Wire Cutters Bulbs Required included 3 candelabra base 60 watt max bulbs DANGER When using an existing outlet box make sure the outlet box is securely atta...

Страница 6: ...unting bracket B to outlet box using screws spring washers and flat washers provided with the outlet box Fig 3 Pull wires from outlet box through center hole in mounting bracket B Note It is very impo...

Страница 7: ...not move or come out once in the correct position NOTE Make sure that motor assembly D does not swing from side to side too easily if it does check to be sure that the plastic lock tab C is FULLY INS...

Страница 8: ...HITE wire from ceiling Connect GROUND GREEN wire from mounting bracket to BARE GREEN wire from ceiling Fig 1A 1 FAN AND LIGHT CONTROLLED BY PULL CHAINS BLACK WHITE GROUND GREEN BARE WHITE BLUE WHITE F...

Страница 9: ...s on opposite side of box from the black and blue if applicable connections Turn spliced taped wires upward and gently push wires and wire connectors CC into outlet box CC CC 2 CC CC E3 Wire Connector...

Страница 10: ...osen these two motor housing mounting screws N Remove the other two motor housing mounting screws N Now lift motor housing A to mounting bracket B again aligning slotted holes in motor housing A with...

Страница 11: ...ing Plate If you wish to USE the light kit remove three screws from switch housing plate on underside of motor Locate BLUE or BLACK and WHITE wires in switch housing plate labeled FOR LIGHT and remove...

Страница 12: ...6 The pull chain extensions J supplied in one of the hardware packs or custom pull chain extensions sold separately may be attached to fan and light pull chains Fig 8 Install three candelabra base 60...

Страница 13: ...h on the switch housing plate for the proper fit Re insert screws that were previously removed Use a Phillips screwdriver to secure all screws Fig 2 Switch Housing Plate L Switch Housing Plate A 3 3 T...

Страница 14: ...ur comfort Note Wait for fan to stop before moving the reverse switch 3 E 3A In warmer weather setting the reverse switch in the LEFT position will result in downward airflow creating a wind chill eff...

Страница 15: ...n power off Loosen motor housing A and check all connections Noisy operation 1 Blades H are loose 1 Tighten all blade screws AA 2 Cracked blade H 2 Replace blade H 3 Full range dimmer switch 3 Replace...

Страница 16: ...e warranty Any replacement of defective parts for the ceiling fan must be reported within the first year from the date of purchase For the balance of the warranty call our customer service department...

Страница 17: ...Ring L Extra Switch Housing N Motor Housing Mounting Screw O Motor Screw P 5 4M M Lock Washer AA Blade Screw BB Fiber Blade Washer CC E3 Wire Connector For replacement parts call our customer service...

Отзывы: