LIMITED LIFETIME WARRANTY

The manufacturer warrants this fan to be free from defects in workmanship and materials present at 

time of shipment from the factory for a lifetime from the date of purchase by the original purchaser. 

The retailer also warrants that all other fan parts, excluding any glass or plastic blades, to be free 

from defects in workmanship and material at the time of shipment from the factory for a period of one 

year after the date of purchase by the original purchaser. The manufacturer agrees to correct such 

defects without charge or at its option replace the ceiling fan with a comparable or superior model.
To obtain warranty service, present a copy of the receipt as proof of purchase. All costs of removing 

and reinstalling the product are your responsibility. Any damage to any part such as by accident or 

misuse or improper installation or by affixing any accessories, is not covered by this warranty. The 

manufacturer assumes no responsibility whatsoever for fan installation during the limited lifetime 

warranty. Any service performed by an unauthorized person will render the warranty invalid.

Due to varying climate conditions, this warranty does not cover any changes in brass finish, including 

rusting, pitting, corroding, tarnishing or peeling. Brass finishes of this type give their longest useful life 

when protected from varying weather conditions. Any glass provided with this fan is not covered by 

the warranty.

Any replacement of defective parts from the ceiling fan must be reported within the first year from the 

date of purchase. For the balance of the warranty, call our customer service department for return 

authorization and shipping instructions so that we may repair or replace the ceiling fan. Any fan or 

parts returned improperly is the sole responsibility of the purchaser. There is no other expressed 

warranty. The manufacturer disclaims any and all warranties. The duration of any implied warranty 

which cannot be disclaimed is limited to the time period as specified in the expressed warranty. The 

manufacturer shall not be liable for incidental, consequential, or special damages arising out of or 

in connection with product use or performance except as may otherwise be accorded by law. This 

warranty gives specific legal rights, and you may also have other rights which vary from state to state.

This warranty supersedes all prior warranties.

Note:

 A small amount of “wobble” is normal and should not be considered a defect.

Содержание CANTLEY 41557

Страница 1: ...rtment at 1 800 643 0067 8 a m 8 p m EST Monday Sunday ATTACH YOUR RECEIPT HERE Purchase Date _________________________ Harbor Breeze is a registered trademark of LF LLC All Rights Reserved AR19032 Fr...

Страница 2: ...mation 5 Preparation 6 Initial Installation 7 Standard or Angle Mounting Instructions 9 Secondary Hanging System 11 Wiring 12 Final Installation 13 Operating Instructions 16 Care and Maintenance 17 Tr...

Страница 3: ...1 H Fitter Plate preassembled to Motor Assembly G 1 I Fitter Plate Screw preassembled to Fitter Plate H 3 J Motor Screw preassembled to Motor Assembly G 6 K Set Screw preassembled to Motor Assembly G...

Страница 4: ...Blade Screw Qty 9 1 extra Blade Washer Qty 9 1 extra Pull Chain Extension Qty 2 Secondary Support Screw Qty 1 Support Washer Qty 1 Screw Cap Qty 9 1 extra Secondary Spring Washer Qty 1 Motor Screw 1...

Страница 5: ...loud humming noise from the fan To reduce the risk of fire or electric shock do NOT use a full range dimmer switch to control the fan speed WARNING To reduce the risk of fire electric shock or persona...

Страница 6: ...following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device PREPARATION Bef...

Страница 7: ...e Mounting is best suited for angled or vaulted ceilings A longer downrod is sometimes necessary to ensure proper blade clearance Important If using the angle mount check to ensure the ceiling angle i...

Страница 8: ...Detach mounting bracket D from canopy E 5 Secure the mounting bracket D to the outlet box using screws and washers provided with the outlet box CAUTION It is very important you use the proper hardware...

Страница 9: ...a longer downrod if required through the canopy E and yoke cover L Thread the wires and braided cable from the fan up through the downrod A 3 Slide the downrod A into the yoke of the motor assembly G...

Страница 10: ...d to cut back the lead wire in Step 10 strip 1 2 in of insulation from the end of the wires Twist the stripped ends of each strand of wire within the insulation with pliers not included Note If you di...

Страница 11: ...ided cable around the secondary support screw JJ Note The ceiling support brace may not be accessible from below If not it must be accessed from above Important The braided cable must make a complete...

Страница 12: ...Black hot supply wire Secure all wiring connections together with wire connectors AA Note If a second hot power wire is available from outlet box connect it to the blue light power wire from the fan...

Страница 13: ...ely 2 Insert the blade screws BB along with the blade washers CC through the blade O and into the blade arm N and secure with a screw cap LL Repeat this step for the remaining blades O and blade arms...

Страница 14: ...key slots on light pan S Re install the third fitter plate screw I into the open hole in light pan S and securely tighten all three fitter plate screws I 5 Remove the three light pan screws T from th...

Страница 15: ...he pull chains Note When facing the reverse switch on the light kit M the fan pull chain is on the right and the light pull chain is on the left Hardware Used DD Pull Chain Extension x 2 9 Turn on the...

Страница 16: ...tch left to display a sun icon which will result in downward airflow creating a wind chill effect Fig 2A In cooler weather push the reverse switch right to display a snowflake icon which will result i...

Страница 17: ...plugs are not connected properly 4 The reverse switch is not completely engaged 1 Turn the power on or check the fuse 2 Turn the power off Loosen the canopy and check all connections 3 Check that the...

Страница 18: ...d separately 3 Turn off the power Loosen the canopy and verify that the mounting bracket is secure to the electrical outlet box The bracket must be flush without movement against the outlet box 4 Use...

Страница 19: ...arying climate conditions this warranty does not cover any changes in brass finish including rusting pitting corroding tarnishing or peeling Brass finishes of this type give their longest useful life...

Страница 20: ...EST Monday Sunday PART DESCRIPTION PART A Downrod 4L000010280 D Mounting Bracket 4L000004480 E Canopy 4L000006320 F Canopy Cover 4L000008290 L Yoke Cover 4A000003540 M Light Kit 4L000012090 N Blade A...

Отзывы: