background image

5.  Fasten the blade bracket (F) to the motor by inserting 

     the alignment post into the slot on the bottom of the 

     motor housing (H) and tightening the blade bracket 

     screws with washers. 

     Please note that the blade bracket screws with washers 

     are pre-installed into the blade bracket (F). Repeat Steps 

     4 and 5 for the remaining blade brackets (F).

6.  Attach the fan pull chain extension (BB).   

13

12

5

6

Lowes.com/harborbreeze

Lowes.com/harborbreeze

Lowes.com/harborbreeze

Lowes.com/harborbreeze

screw with

washer

alignment

post

slot

F

H

FINAL INSTALLATION

OPERATING INSTRUCTIONS
PULL CHAIN:

 The fan pull chain is for motor speed control: High, Medium, Low and Off. Pull the 

chain once for each position.

REVERSE SWITCH:

 

When the season changes, you may want to change to the direction your fan 

spins. To switch between clockwise and counterclockwise rotation, flip the fan reversal switch. 

Note: Wait for fan to stop before reversing the switch.

A. In cooler weather, clockwise rotation creates an upward air flow, which moves hot air from the   

    ceiling into the room. Push the switch UP.

B. In warmer weather, counterclockwise rotation creates a downward air flow, which cools the air.    

    Push the switch DOWN.

• To reduce the risk of fire, electric shock or injury to persons, maintain this fan.

• 

Important:

 Shut off main power supply before beginning any maintenance.

• Do not use water or detergents when cleaning the fan or fan blades. A dry dust cloth or lightly 

  dampened cloth will be suitable for most cleaning.

• Clean fan housing with only a soft brush or lint-free cloth to avoid scratching the finish. Clean 

  blades with a lint-free cloth. You may occasionally apply a light coat of furniture polish to blades for 

  added protection.

• At least twice each year, tighten all screws and lower canopy to check mounting bracket screws 

  and downrod assembly.

CARE AND MAINTENANCE

TROUBLESHOOTING

PROBLEM

POSSIBLE CAUSE

CORRECTIVE ACTION

Excessive wobbling.  1. Blades are loose.                               1. Tighten all blade screws.

                                  2. Blade brackets incorrectly attached.  2. Reinstall blade brackets.

                                  3. Unbalanced blades.                           3. Switch with blade from opposite side.

                                  4. Fan not securely mounted.                4. Turn power off. Carefully loosen

                                  5. Fan too close to vaulted ceiling.            canopy; remount securely.

                                                                                                 5. Lower fan or move it to another

                                                                                                     location.

Noisy operation.        1. Blades are loose.                                1. Tighten all blade screws.

                                  2. Cracked blade.                                    2. Replace blades (call customer 

                                  3. Unapproved speed control.                     service).

                                                                                                  3. Replace with an approved speed

                                                                                                       control device.    

Fan does not move.  1. Chain switch is “off”.                           1. Pull chain switch. 

                                  2. Faulty wire connection.                       2. Turn power off. Loosen canopy,

                                  3. Reverse switch not engaged.                  check all connections.

                                                                                                  3. Push switch firmly either way.

Hardware Used

x 1

 Fan pull chain extension

BB

BB

Содержание CALERA 00830

Страница 1: ...Harbor Breeze is a registered trademark of LF LLC All Rights Reserved Questions problems missing parts Before returning to your retailer call our customer service department at 1 800 643 0067 8 a m 6...

Страница 2: ...tected branch circuit WARNING PERSONAL INJURY HAZARD To reduce the risk of injury to persons install fan so that the blade is at least 7 ft above the floor CAUTION READ AND SAVE THESE INSTRUCTIONS FIR...

Страница 3: ...Canopy Cover preassembled to canopy B 1 D Yoke Cover 1 E Downrod Assembly 1 F Blade Bracket 5 G Blade 5 H Motor Housing 1 I Mounting Screw preassembled to motor housing H 3 Before beginning assembly...

Страница 4: ...the slotted screws This will enable you to remove the mounting bracket A 4 Install the mounting bracket A to the outlet box not included sliding the mounting bracket A over the two outlet box screws n...

Страница 5: ...ing bracket A Warning Be carefully when aligning the tab to the slot If not fully engaged there is a possibility of fan falling which may result in serious injury or death You may now proceed to the W...

Страница 6: ...Be sure no bare wire or wire strands are visible after making connection Place green and white connections on opposite side of box from the black and blue connections The splices should be turned upwa...

Страница 7: ...tain this fan Important Shut off main power supply before beginning any maintenance Do not use water or detergents when cleaning the fan or fan blades A dry dust cloth or lightly dampened cloth will b...

Страница 8: ...fetime limited warranty Any service performed by an unauthorized person will render the warranty invalid Due to varying climate conditions this warranty does not cover changes in brass finish rusting...