background image

20

LIMITED LIFETIME WARRANTY

Printed in China

JMLI1803

The distributor warrants this fan to be free from defects in workmanship and materials present at time of 
shipment from the factory for Lifetime limited from the date of purchase.  This warranty applies only to the 
original purchaser. The distributor agrees to correct any defect at no charge or, at our option, replace the 
ceiling fan with a comparable or superior model.

To obtain warranty service, present a copy of your sales receipt as proof of purchase.  All cost of removal 
and reinstallation are the express responsibility of the purchaser.  Any damage to the ceiling fan by 
accident, misuse or improper installation, or by using parts not produced by the manufacturer of this fan or 
affixing accessories not produced by the manufacturer of this fan, are the purchaser's own responsibility.  
The distributor assumes no responsibility whatsoever for fan installation during the limited lifetime warranty.  
Any service performed by an unauthorized person will render the warranty invalid.

Due to varying climatic conditions, this warranty does not cover changes in brass finish, rusting, pitting, 
tarnishing, corroding or peeling.  Brass finish fans maintain their beauty when protected from varying 
weather conditions.  Any glass provided with this fan is not covered by the warranty.

Any replacement of defective parts for the ceiling fan must be reported within the first year from the date of 
purchase.  For the balance of the warranty, call our customer service department (

at 

1-800-643-0067)

 for 

return authorization and shipping instructions so that we may repair or replace the ceiling fan.  Any fan or 
parts returned improperly packaged is/are the sole responsibility of the purchaser.  There is no further 
express warranty.  The distributor disclaims any and all implied warranties.  The duration of any implied 
warranty which cannot be disclaimed is limited to the limited lifetime period as specified in our warranty.  
The distributor shall not be liable for incidental, consequential or special damages arising at or in 
connection with product use or performance except as may otherwise be accorded by law.  This warranty 
gives you specific legal rights and you may also have other rights which vary from state to state.  This 
warranty supersedes all prior warranties.

REPLACEMENT PARTS LIST

For replacement parts, call our customer service department at 

1-800-643-0067

, 8 a.m. - 6 p.m., EST, 

Monday - Thursday,  8 a.m. - 5 p.m., EST, Friday.

A

B

C

G

I

 A  Downrod
 B  Canopy
 C  Mounting 

Bracket

 G  Blade 
 J  Blade 

Arm

 

Switch Housing Cap

DESCRIPTION

PART

PART #

0995853-A
0995853-B
0995853-C
0995853-G
0995853-J
0995853-M

J

M

Содержание CAF48BNK5L

Страница 1: ...4 ITEM 0955853 MODEL CAF48BNK5L Questions problems missing parts Before returning to your retailer call our customer service department at 1 800 643 0067 8 a m 6 p m EST Monday Thursday 8 a m 5 p m EST Friday PH18100 Harbor Breeze is a registered trademark of LF LLC All Rights Reserved ...

Страница 2: ...ions are secure to prevent the fan from falling The net weight of CAF48 including the light kit is 16 lbs TABLE OF CONTENTS 2 SAFETY INFORMATION DANGER When using an existing outlet box make sure the outlet box is securely attached to the building structure and can support the full weight of the fan Failure to do this can result in serious injury or death The stability of the outlet box is essenti...

Страница 3: ...e installation be sure to shut off electricity at main switch or circuit breaker in order to avoid electrical shock WARNING CAUTION Be sure outlet box is properly grounded and that a ground wire green or bare is present Before beginning installation carefully check all screws bolts and nuts on fan motor assembly to ensure they are secure The below FCC warning is for the included LED Light bulbs Th...

Страница 4: ...eassembled 1 M Switch Housing Cap 1 preassembled DESCRIPTION PART QUANTITY N Switch Housing Cap Screw 3 preassembled O Finial preassembled 1 P Glass Shade 1 Q Rubber Washer 1 preassembled R Balancing Kit 1 S Motor Screw 10 preassembled 1 extra T Washer preassembled 10 1 extra U Pull Chain Extension 2 V Pin preassembled 1 W Clip preassembled 1 X Star Washer preassembled 4 Y Canopy Mounting Screw 4 ...

Страница 5: ...stimated Assembly Time 120 minutes Tools Required for Assembly not included Electrical Tape Phillips Screwdriver Pliers Safety Glasses Stepladder and Wire Strippers Helpful Tools not included AC Tester Light Tape Measure Do It Yourself Wiring Handbook and Wire Cutters Fiber Blade Washer Qty 15 1 extra Blade Screw Qty 15 1 extra Wire Connector Qty 4 INITIAL INSTALLATION Turn off circuit breakers an...

Страница 6: ...e mounting is best suited for ceilings 8 ft or higher For taller ceilings you may want to use a longer downrod not included Angle style mounting is best suited for angled or vaulted ceilings A longer downrod is sometimes necessary to ensure proper blade clearance Closemount style mounting is more suitable for ceilings lower than 8 ft 2 4a Loosen canopy mounting screws Y in slotted holes of canopy ...

Страница 7: ...b 4b Open End C C ANGLE MOUNT STANDARD MOUNT 5 Remove preassembled motor screws S and washers T from underside of motor housing D If there are plastic motor blocks installed with the motor screws S discard the plastic motor blocks Note Make sure to keep loose hardware separate to avoid confusion during installation For DOWNROD STYLE FAN MOUNTING proceed to step 1 below For CLOSEMOUNT STYLE FAN MOU...

Страница 8: ...y need to cut the lead wires back to simplify the wiring If you decide to cut back the lead wires it is suggested you do so in the following manner Take the lead wires and make sure you have pulled them all the way through the top of the downrod Start at the TOP of the hanging ball on the downrod and measure 8 in of lead wire and then cut the excess wire off with wire cutters not included NOTE If ...

Страница 9: ...he slots in hanging ball with tab in mounting bracket C DANGER Failure to align one of the slots in the ball with the tab may result in serious injury or death Hanging Ball Slot A 6 C Tab CLOSEMOUNT STYLE FAN MOUNTING Remove preassembled canopy cover from bottom of canopy B NOTE It may be necessary to use the handle end of a screwdriver not included to remove the canopy cover by tapping on the can...

Страница 10: ...otor housing D using three screws and lock washers previously removed 3 Temporarily hang fan on the tab on the mounting bracket C using one of the non slotted holes in the canopy B 4 C 4 Remove every other preassembled screw and lock washer from top of motor housing D 2 B Tab Hole Screw Washer Screw Washer 2 D B D J ...

Страница 11: ...OLLED BY TWO WALL SWITCHES FAN CONTROLLED BY PULL CHAIN LIGHT BY WALL SWITCH BLACK BLACK WALL SWITCH BLUE 1b WHITE BLACK POWER WHITE NEUTRAL GROUND GREEN BARE BLACK 120V POWER FROM CEILING GREEN GREEN NOTE This fan is remote control adaptable remote control not included Please refer to instructions provided with the remote control before proceeding with these wiring instructions Choose wiring diag...

Страница 12: ...ACK WALL SWITCH FOR LIGHT GREEN 1 1 Lift canopy B to mounting bracket C and align slotted holes in canopy B with loosened canopy mounting screws Y in mounting bracket C Twist canopy B to lock then insert the two canopy mounting screws Y and star washers X previously removed Step 4a page 6 Tighten all canopy mounting screws Y securely B B A D D Y X FINAL INSTALLATION 1c FAN AND LIGHT CONTROLLED BY ...

Страница 13: ...blade screws BB securing blade arm J to blade G by tightening blade screws BB starting with the one in the middle Repeat for remaining blades G and blade arms J Hardware Used Blade Screw x 15 BB Fiber Blade Washer x 15 CC CC BB G J Attach blade arms J to the bottom of motor housing D with motor screws S and washers T previously removed Step 5 page 7 Tighten motor screws S securely Note Make sure t...

Страница 14: ...ousing cap M with the reverse switch on switch housing for the correct fit Re insert the switch housing screws N previously removed Step 4 page 13 then tighten all switch housing cap screws N with a Phillips screwdriver not included Install bulbs H CAUTION When replacing bulb s allow bulb s and glass shade to cool down before touching 7 7 H H Remove finial O finial plate I hex nut K and rubber was...

Страница 15: ... through corresponding holes in glass shade P Push up gently on glass shade P until threaded rod comes through hole Be sure fan pull chain does not rub against bulbs during fan operation Secure glass shade P with hex nut K finial plate I and finial O CAUTION Do NOT overtighten finial O as glass may crack or break 9 9 For Fan For Light U Attach applicable pull chain extensions U or custom pull chai...

Страница 16: ... hole in the middle of the switch housing cap M F L M K WHITE BLACK 1 1 2 Hardware Used Cap x 1 AA Place cap AA firmly in hole in middle of switch housing cap M Align holes in switch housing cap M with holes in switch housing then attach switch housing cap M with previously removed switch housing cap screws N Note Make sure to align notch on top edge of the switch housing cap M with the reverse sw...

Страница 17: ... ceiling fan will allow you to raise your thermostat setting in summer and lower your thermostat setting in winter without feeling a difference in your comfort NOTE Wait for fan to stop before moving the reverse switch 3 Switch Housing Switch Housing The pull chain located on the switch housing has four positions to control fan speed One pull is HIGH two is MEDIUM three is LOW and four turns the f...

Страница 18: ...ree cloth You may occasionally apply a light coat of furniture polish to wood blades for added protection IMPORTANT Shut off main power supply before beginning any maintenance Do not use water or a damp cloth to clean the ceiling fan Bulb Replacement Use standard base 6 5 watt LED bulbs or incandescent CFL equivalent OPERATING INSTRUCTIONS 3a In warmer weather setting the reverse switch in the DOW...

Страница 19: ...lade screws 2 Replace blade 3 Replace with an approved speed control device 4 Allow fan a break in period of a few days especially when running the fan at Medium and High speeds 1 Blades are loose 2 Blade arms incorrectly attached 3 Unbalanced blades 4 Fan not securely mounted 5 Fan too close to vaulted ceiling 6 Set screw s on motor housing yoke is are not tightened properly 1 Tighten all blade s...

Страница 20: ...n protected from varying weather conditions Any glass provided with this fan is not covered by the warranty Any replacement of defective parts for the ceiling fan must be reported within the first year from the date of purchase For the balance of the warranty call our customer service department at 1 800 643 0067 for return authorization and shipping instructions so that we may repair or replace t...

Отзывы: