6
Lowes.com/harborbreeze
AssEmbLY INsTRUCTIONs
5. Remove the existing wire connectors from the white
and blue wires labeled FOR LIGHT in the switch
housing. Connect the white wire from the light kit
fitter (A) to the white wire from the fan. Connect the
black wire from the light kit fitter (A) to the blue wire
from the fan. (Fig. 5a/Fig. 5b) If applicable, reconnect
the male plug from the motor housing to the female
plug from the switch housing. Ensure the plugs
connect securely. (Fig. 5a)
wARNING:
To reduce the risk of fire, electrical shock
or personal injury, each wire connector used with this
light kit should accept only one 18-gauge wire from
the light kit and one 18-gauge wire from the ceiling
fan. If there are three or more wires to connect or
any of the wires is larger than 18 gauges, consult an
electrician for the proper size wire connectors to use.
5a
5
Switch
White
White
White
White
Black
Black
Blue
Blue
Housing
Male
Plug
Female Plug
Switch
Housing
Switch
Housing
Cap
6. Reconnect the existing wire connectors and twist in a
clockwise direction. Wrap electrical tape around each
individual wire connector down to the wire.
6
7. Align three holes in the switch housing with three
holes in the switch housing plate. Re-attach the
switch housing with the three screws that were
removed in Step 2. Tighten all screws securely.
(Fig.7a)
Note:
To re-connect the switch housing cap, align the
holes in the switch housing cap with the holes at
the bottom of the switch housing and use the three
previously removed screws to secure the switch
housing cap. (Fig. 7b)
Note:
When attaching switch housing or switch housing
cap, turn assembly as necessary to ensure fan pull
chain falls between glass shades and functions
without interference.
7a
7
Switch
Housing
Switch
Housing
Plate
Motor
Housing
Switch
Housing
Cap
Motor
Housing