HANYOUNG NUX HSR-SL Скачать руководство пользователя страница 3

▍Specification

▍Dimension

[Unit : mm]

Model

Low

HSR-SLD152Z

HSR-SLD252Z

HSR-SLD402Z

High HSR-SLD154Z

HSR-SLD254Z

HSR-SLD404Z

Rated Load 

Voltage

Low

90 - 264 V a.c.

High

90 - 480 V a.c.

Peak Voltage

(Non-repetition)

Low

600 V

High

800 V

1,200 V

Rated load current

15 A 

25 A

40 A

Frequency

50/60 ㎐(Dual usage)

Input current 60 Hz

(8.3 ms non-recurring)

Low

170 A

260 A

420 A

High

170 A

250 A

370 A

Input current 50 Hz

(10 ms non-recurring)

Low

160 A

250 A

400 A

High

160 A

230 A

350 A

Leakage current

20 ㎃ max

Output ON voltage dropping

1.6 V (R.M.S) max

Rated Voltage

5 - 24 V d.c.

Operating Voltage Range

4 - 32 V d.c.

Impedance

Less than 4 ㏀

Operation Voltage

More than 3 V d.c.

Reset Voltage

Less than 1.5 V d.c.

Input Current

Constant-current system : 8 ㎃ (±3)

Response Time

1/2 Cycle + 1 ms max. (“R” type below 1 ms)

Insulating Resistance

500 V d.c.,  100 ㏁ (Between the input / output and case) 

Dielectric strength

 3,000 V a.c. (For 1 min at 60 ㎐)

Vibration resistance

10 - 55 ㎐, Double amplitude : 1.5 ㎜ each X,Y and Z 

direction for 2 hours

Shock resistance

1,000 ㎨, X·Y·Z each axis 3 times

Storage Temperature

-30 ~ 90 ℃ 

Ambient Temperature

-5 ~ 40 ℃ (But without frostiness)

Ambient Humidity

45 ~ 85 % RH

Pollution rate

2nd rating

Purpose of use

Resistance/Inductive load

Accepted standard

IEC 62314

Weight (Including box)

Approx 230g

Approx 372g 

▍Safety information

• The input/output terminals are subject to electric shock risk. 

   Never let the input/output terminals come in contact with your body or conductive substances.

DANGER

•Before you use, please read safety precautions carefully, and use this product properly.

• If you are concerned about serious accident due to the malfunction of products, 

  please install the external safety equipment

• To prevent defection or malfunction of this product, supply proper power voltage in 

  accordance with the rating.

• To prevent electric shock or devise malfunction of this product, do not supply the 

  power until the wiring is completed.

• Reassemble this product while the power is off. Otherwise, it may cause malfunction or electric shock.

• If the user uses the product with methods other than specified by the manufacturer, 

  it will brings the bodily injuries or property damages.

• Due to the danger of electric shock, please use this product installed onto a panel while 

  an electric current is applied.

WARNING

• Before using the product you have purchased, please check out if it is exactly what you ordered.

• Do not use this product at any place with corrosive gas (especially noxious gas or ammonia) or 

flammable gas.

• Do not use this product at any place with liquid, oil, medical substances, dust, salt or iron contents.

• Do not use this product at any place with excessive induction trouble, static electricity or magnetic noise.

• Do not use this product at any place with possible thermal accumulation due to direct sunlight or heat radiation.

• When the product gets wet, the inspection is essential because there is a danger of an electric 

leakage or fire.

•Do not connect anything to the unused terminals.

•For DC types, please connect wires at the correct position after checking polarity of terminal.

•When product is disposed, treat as a industrial waste.

•Since a heat sink corner is sharp, it would lead to a serious injury.

• When electricity flows, desktop or heat sink's corner temperature would be high so that it could 

lead people to suffer burns.

•When it is out of order, please separate SSR from head sink and change only SSR.

•This model has epoxy molding for the purpose of safety, reliability and extends of the life.

• When applying an electric current, SSR is heated more and more. So, it has more durable at low 

heat sink temperature and ambient temperature. 

CAUTION

DANGER

DANGER indicates an imminently hazardous situation which, if not 

avoided, will result in death or serious injury

WARNING

WARNING indicates a potentially hazardous situation which, if not 

avoided, could result in death or serious injury

CAUTION

CAUTION indicates a potentially hazardous situation which, if not 

avoided, may result in minor or moderate injury

Before using the product, please read the safety information thoroughly and use it properly. Alerts declared 

in the manual are classified to Danger, Warning and Caution by their criticality.

LO

AD

INPUT

■ Measurement for CE certified products

   Single-Phase Solid State Relay

 

HSR-SL

      Thank you for purchasing HANYOUNG product.

      Please check whether the product is the exactly same as you ordered. 

      Before using the product, please read this instruction manual carefully.

     Please keep this manual where you can view at any time

 INSTRUCTION MANUAL

28, Gilpa-ro 71beon-gil, Michuhol-gu, 

Incheon, Korea

TEL : +82-32-876-4697 

http://www.hanyoungnux.com

HANYOUNGNUX CO.,LTD

HEAD OFFICE

MC0501KE210119

● HSR-SLD15

     HSR-SLD25

● HSR-SLD2C15□

● HSR-SLD40

17.4

4.5

5.5

90

99

4.5

44.4

98.5

17.4

4.5

5.5

90

99

4.5

22.4

17.4

4.5

5.5

90

99

4.5

45.4

※  2 contact : Only available for 15 A items  (HSR-SLD2C152Z, HSR-SLD2C154Z)

▍Suffix code

Model

Code

Description

HSR-SL

□ □ □ □ □ -□ Slim Type Single-Phase Solid State Relay

Input voltage D

4 - 32 V d.c.

Contact

-

1 contact (No mark)

2C

2 contacts (Only for 15 A)

Rated load current

15

15 A

25

25 A

40

40 A

Rated load voltage

2

 90 - 264 V a.c. (Low)

4

 90 - 480 V a.c. (High)

Operation method 

Z

Zero Cross Switching (Standard)

R

Random Switching

Option

-

None (No mark)

BI 60 °C, 80 °C Bimetallic Mounting

Model

Code

Description

HSR-SL

□ □ □ □ □ -S Slim Type Single-Phase Solid State Relay

Input voltage D

4 - 32 V d.c.

Contact

-

1 contact (No mark)

Rated load current

15

15 A

25

25 A

40

40 A

Rated load voltage

2

 90 - 264 V a.c. (Low)

4

 90 - 480 V a.c. (High)

Operation method 

Z

Zero Cross Switching (Standard)

■ S-MARK certified products

■ CE certified products

Содержание HSR-SL

Страница 1: ... 무접점릴레이 입력전압 D 4 32 V d c 접점 1접점 표기없음 2C 2접점 15 A 만 해당 정격부하 전류 15 15 A 25 25 A 40 40 A 사용부하 전압 2 90 264 V a c 저압용 4 90 480 V a c 고압용 동작방법 Z 제로크로스 스위칭 표준품 R 랜덤 스위칭 옵션 옵션 없음 표기없음 BI 60 C 80 C 바이메탈 장착 사 양 외형치수 단위 mm HSR SLD15 HSR SLD25 HSR SLD2C15 CE 기준 적용 치수 HSR SLD40 형 명 저압용 HSR SLD152Z HSR SLD252Z HSR SLD402Z 고압용 HSR SLD154Z HSR SLD254Z HSR SLD404Z 부 하 사용부하전압 저압용 90 264 V a c 고압용 90 480 V a c 피크전압...

Страница 2: ...100 주위온도 50 40 30 20 12 6 30 20 0 20 40 60 80 100 주위온도 50 40 30 18 10 30 20 0 20 40 60 80 100 주위온도 50 40 32 20 10 30 20 0 20 40 60 80 100 25 40 주위온도 50 40 30 20 10 30 20 0 20 40 60 80 100 HSR SLD25 HSR SLD40 부하 전류 특성 25 기준 주위온도 부 하 전 류 A 부 하 전 류 A 부 하 전 류 A 부 하 전 류 A 부 하 전 류 A 부 하 전 류 A 50 40 30 20 10 15 6 30 20 0 20 40 60 80 100 주위온도 50 40 30 20 25 10 30 20 0 20 40 60 80 100 주위온도 50 40 30 20 12 6...

Страница 3: ...o not use this product at any place with possible thermal accumulation due to direct sunlight or heat radiation When the product gets wet the inspection is essential because there is a danger of an electric leakage or fire Do not connect anything to the unused terminals For DC types please connect wires at the correct position after checking polarity of terminal When product is disposed treat as a...

Страница 4: ... Use clamping unit or lug when tightening it How to install Please install SSR in the vertical direction Otherwise production performance may be reduced to less than 50 Since the weight of the product is heavy install it stably when installing DIN rail Input current Characteristics Load current Characteristics 40 Ambient Temperature Ambient Temperature Ambient Temperature Ambient Te Ambient Temper...

Отзывы: