![HANYOUNG NUX HE Series Скачать руководство пользователя страница 1](http://html2.mh-extra.com/html/hanyoung-nux/he-series/he-series_instruction-manual_3738145001.webp)
MI0115E080226
Ratings
Specification
HEAD OFFICE
1381-3, Juan-Dong, Nam-Gu Incheon, Korea
TEL: (82-32)876-4697 FAX : (82-32)876-4696
MAIN PRODUCTS
- DIGITAL : Temperature Controller, Counter, Timer,Speedmeter,
Tachometer, Panel Meter, Recorder
- SENSOR : Proximity Sensor/Photo Electric Sensor,
Rotary Encoder, Optical Fiber Sensor,
Pressure Sensor
- ANALOG : Timer, Temperature Controller
Rotary Encoder
HE series
Thank you for purchasing HANYOUNG product.
Please check whether the product is the exactly same as
you ordered. Before using the product, please read this
instruction manual carefully.
INSTRUCTION MANUAL
1. If intense vibration or impact is applied on the transmitter for length measurement, the wrong
pulse is generated causing malfunction, therefore, absolute care is necessary when selecting
the installation and disposition location.
2. As much as the amount of pulse per cycle, the slit gap of rotation slit is narrower, therefore can
be easily affected by vibration, and the vibration applied during slow rotation or when
stationary, may get transmitted to the shaft or the main body, causing wrong pulse generation,
therefore, please take caution. The vibration applied to the transmitter for length measurement
can become a cause for wrong pulse generation, so please take caution in terms of
installation location or location for attachment.
An internal pressure of 500V DC exists between the Case and the electric circuit, however, there
are dangers of damage the electrical circuit if voltage is applied accidentally, so do not perform
mega tests.
On Mega Test
1. During installation, do not apply impact on or twist the shaft of the transmitter for length
measurement.
2. During installation, do not apply excessive force when combining the shaft of transmitter for
length measurement and the instrument.
3. During installation, take caution because the life span of the transmitter for length
measurement is dependent on the usage condition and the environment.
4. Do not decompose, modify, revise or repair this product. This may be a cause of malfunction,
electric shock or fire.
5. Reassemble this product while the power is OFF. Otherwise, it may be a cause of malfunction
or electric shock.
On Installation
About vibration
1. Separate an input signal cable from an output signal cable. If separating is not possible,
please use the input signal cable after shielding it.
2. If there is excessive noise from the power supply, using insulating transformer and noise filter
is recommended.
3. Do not connect anything to the unused terminals.
4. After checking the polarity of terminal, connect wires at the correct position.
5. As for wiring, ensure they are as short as possible.
6. Having the same pipe for wiring of the transmitter for length measurement with the power line
or an identical connection could cause malfunction, therefore please take caution.
7. Wrong connection of the wiring of transmitter for length measurement may damage the
internal circuit. Please take sufficient caution.
About Wiring
1. Before using the product you purchased, make sure that it is exactly what you ordered.
2. Make sure that there is no damage or abnormality of the product during the delivery.
3. The transmitter for measuring the length is composed of precision parts, so can easily be
damaged with external impact, therefore handle with care.
4. The shield wire of the transmitter for length measurement is not connected to the case.
5. When the product gets wet, the inspection is essential because there is danger of an electric
leakage or fire.
6. For the continuous and safe use of this product, the periodical maintenance is recommended.
7. If you use the product with methods other than specified by the manufacturer, there may
be bodily injuries or property damages.
Safety information
CAUTION
As for
Rotary Encoder Case,
connect on the control board case
by 3~5.5MM electric wire. For the
0 V terminal, connect on the
control board case with identical
type of electrical wire and earth it.
Perform as indicated above,
and earth the
Rotary Encoder.
Distance from
control box
30 m Max.
30 m Min.
Wiring of Rotary Encoder
For noise prevention
The caution on the safety stated above, must be kept, otherwise malfunction
can be induced.
Mode
HE40B
40 mm
Shaft type
HE50B
50 mm
Shaft type
Shaft external
diameter
6 : 6 mm
8 : 8 mm
(Option)
8 : 8 mm
Phase
type
2 : A,B
3 : A, B, Z
3C : A, B,
/Z
4 : A, /A,
B, /B
6 : A, /A,
B, /B
Z, /Z
(Standard :
A, B, Z)
Pulse number per
revolution
*1,10,50,60,100,
120,200,250,300,360
,400,500,512,600,80
0,1000,1024,2000,20
48,3000,3600,5000
*1,10,50,60,100,
120,200,250,300,360
,400,500,512,600,80
0,1000,1024,2000,20
48,3000,3600,5000
“ * ” mark : Only A, B phase can output (Line Drive output is A, /A, B, /B)
The item that is not in the above revolution is order made product
Output type
O : NPN
Open
collector
N : NPN
Voltage
T : Totem-
pole
L : Line driver
(Line Drive:
5V d.c)
Power
voltage
5 : 5 V d.c
12 : 12 V d.c
(5-12 V d.c)
24 : 24 V d.c
(12-24 V d.c)
Wire
Specification
No mark:
Standard type
C : Connector
HE40B
6
600
3
T
24
HE
B
- - - -N-
NPN Voltage output
A, B, Z phase
A,B,Z,A,B,Z phase
Phase difference between A. B phase:
T/4
T/8(Cycle of A phase = T)
300 kHz
5 - 12 V d.c / 12 - 24 V d.c
5 % 5 V d.c
5 %
70 mA Max. (No-load) Line Drive output below 30 mA (No-load)
WIRE
40 : 40 gf
(0.004 N m Max.)
50 : 80 gf
(0.008 N m Max.)
40 : 40 g
Max., 50 : 80 g
Max.
40 : Radial : Within 2 kgf, Thrust : Within 1 kgf
50 : Radial : Within 2.5 kgf, Thrust : Within 1.2 kgf
5000 rpm
1.2 x 10
8
/rpm : hour
Over 100
(Base on 500 V d.c mega between terminal and case)
800 V a.c (Between terminal and case at 60Hz for 1 minute)
10~55Hz (Cycle for 1 minute), Double amplitude width: 1.5mm, Each X Y Z direction for 2 hours
40 : 50 G Max., 50 : 75 G Max.
-10 ~ 60 (Without condensation), Storage Temperatur : -25 ~ 85
35 ~ 85 % R.H.
Protection IP 50 (IEC Standard)
5 P, 5.0 mm, Length : 1.5 m, Shield cable
(Line Driver Type : 8P, 5.0 mm, Length : 1.5 m, Shield cable)
40 : 170 g, 50 : 200 g
8.0 mm Coupling, Bracket ( 40mm Bracket Separate sales)
Load voltage : 30 V Max.
Load Current : 30 mA Max.
Residual Voltage : 0.4 V Max.
1
Max.
(Cable length 1.5 m / sink=30 mA)
1
Max.
(Cable length 1.5 m /
sink=10 mA)
1
Max.
(Cable length 1.5 m /
sink = 30 mA)
For Low
Load Current: 30 mA
Max.
Residual Voltage: 0.4 V
Max.
For High
Load Current: 10 mA
Max.
Residual Voltage: Above
-2.5V of rated voltage
For Low Load Current:
20 Max.
Residual Voltage: 0.4 V
Max.
For High
Load Current: 20 mA
Max.
Residual Voltage: 2.5 V
Max.
HE
B
- - - -O-
NPN Open collector output
HE
B
- - - -T-
Totem Pole Output
HE
B
- - - -L-
Line Driver Output
Mode #
Output type
Output type
Phase difference
on Output
Max Response
Frequency
Power voltage
Current
Consumption
Connection method
Control output
Response Time
Starting Torque
Moment of inertia
Permissible Shaft
Loading
Max. Permissible
Revolution
Bearing Life
Insulation Resistance
Dielectric strength
Vibration Resistance
Shock Resistance
Operating Ambient
Temperature
Operating Ambient
Humidity
Protection
Wire Specification
Weight
Accessory
Electrical Specification
Mechanical Specification