MI0115E080226 

Ratings

Specification

HEAD OFFICE 

1381-3, Juan-Dong, Nam-Gu Incheon, Korea

TEL: (82-32)876-4697  FAX : (82-32)876-4696

MAIN PRODUCTS
- DIGITAL : Temperature Controller, Counter, Timer,Speedmeter, 

Tachometer, Panel Meter, Recorder

- SENSOR : Proximity Sensor/Photo Electric Sensor, 

Rotary Encoder, Optical Fiber Sensor,   
Pressure Sensor

- ANALOG : Timer, Temperature Controller

Rotary Encoder

HE series

Thank you for purchasing HANYOUNG product.

Please check whether the product is the exactly same as    
you ordered. Before using the product, please read this      
instruction manual carefully.

INSTRUCTION MANUAL

1. If intense vibration or impact is applied on the transmitter for length measurement, the wrong  

pulse is generated causing malfunction, therefore, absolute care is necessary when selecting 
the installation and disposition location.

2. As much as the amount of pulse per cycle, the slit gap of rotation slit is narrower, therefore can 

be easily affected by vibration, and the vibration applied during slow rotation or when  
stationary, may get transmitted to the shaft or the main body, causing wrong pulse generation, 
therefore, please take caution. The vibration applied to the transmitter for length measurement  
can become a cause for wrong pulse generation, so please take caution in terms of 
installation location or location for attachment.

An internal pressure of 500V DC exists between the Case and the electric circuit, however, there
are dangers of damage the electrical circuit if voltage is applied accidentally, so do not perform
mega tests.

On Mega Test

1. During installation, do not apply impact on or twist the shaft of the transmitter  for length  

measurement.

2. During installation, do not apply excessive force when combining the shaft of transmitter for  

length measurement and the instrument.

3. During installation, take caution because the life span of the transmitter for  length 

measurement is dependent on the usage condition and the environment.  

4. Do not decompose, modify, revise or repair this product. This may be a cause of malfunction, 

electric shock or fire.

5. Reassemble this product while the power is OFF. Otherwise, it may be a cause of malfunction    

or electric shock.

On Installation

About vibration

1. Separate an input signal cable from an output signal cable. If separating is not possible,

please use the input signal cable after shielding it.

2. If there is excessive noise from the power supply, using insulating transformer and noise filter

is recommended.

3. Do not connect anything to the unused terminals. 
4. After checking the polarity of terminal, connect wires at the correct position.
5. As for wiring, ensure they are as short as possible.
6. Having the same pipe for wiring of the transmitter for length measurement with the power line  

or an identical connection could cause malfunction, therefore please take caution.

7. Wrong connection of the wiring of transmitter for length measurement may damage the 

internal circuit. Please take sufficient caution.

About Wiring

1. Before using the product you purchased, make sure that it is exactly what you ordered.
2. Make sure that there is no damage or abnormality of the product during the delivery.
3. The transmitter for measuring the length is composed of precision parts, so can easily be  

damaged with external impact, therefore handle with care.

4. The shield wire of the transmitter for length measurement is not connected to the case.
5. When the product gets wet, the inspection is essential because there is danger of an electric  

leakage or fire.

6. For the continuous and safe use of this product, the periodical maintenance is recommended.
7. If you use the product with methods other than specified by the manufacturer, there may 

be bodily injuries or property damages.

Safety information

CAUTION

As for 

Rotary Encoder Case,

connect on the control board case
by 3~5.5MM electric wire. For the
0 V terminal, connect on the
control board case with identical
type of electrical wire and earth it.
Perform as indicated above,
and earth the 

Rotary Encoder.

Distance from

control box

30 m Max.

30 m Min.

Wiring of Rotary Encoder

For noise prevention

The caution on the safety stated above, must be kept, otherwise malfunction

can be induced. 

Mode

HE40B

40  mm

Shaft type

HE50B

50  mm

Shaft type

Shaft external

diameter

6 :  6 mm

8 :  8 mm

(Option)

8 :  8 mm

Phase

type

2 : A,B

3 : A, B, Z

3C : A, B,   

/Z

4 : A, /A, 

B, /B

6 : A, /A, 

B, /B

Z, /Z

(Standard : 

A, B, Z)

Pulse number per

revolution

*1,10,50,60,100,

120,200,250,300,360

,400,500,512,600,80

0,1000,1024,2000,20

48,3000,3600,5000

*1,10,50,60,100,

120,200,250,300,360

,400,500,512,600,80

0,1000,1024,2000,20

48,3000,3600,5000

“ * ” mark : Only A, B phase can output (Line Drive output is A, /A, B, /B)

The item that is not in the above revolution is order made product

Output type

O : NPN

Open      

collector

N : NPN 

Voltage

T : Totem-

pole

L : Line driver

(Line Drive:

5V d.c)

Power

voltage

5 : 5 V d.c      

12 : 12 V d.c

(5-12 V d.c)

24 : 24 V d.c

(12-24 V d.c)

Wire

Specification

No mark:

Standard type

C : Connector

HE40B

6

600

3

T

24

HE

B

- - - -N-

NPN Voltage output

A, B, Z phase

A,B,Z,A,B,Z phase

Phase difference between A. B phase:  

T/4 

T/8(Cycle of A phase = T)

300 kHz

5 - 12 V d.c / 12 - 24 V d.c 

5 %                                                      5 V d.c 

5 %

70 mA Max. (No-load) Line Drive output below 30 mA (No-load)

WIRE

40 : 40 gf

(0.004 N m Max.)

50 : 80 gf

(0.008 N m Max.)

40 : 40 g

Max.,   50 : 80 g

Max.

40 : Radial : Within 2 kgf,  Thrust : Within 1 kgf 

50 : Radial : Within 2.5 kgf,  Thrust : Within 1.2 kgf

5000 rpm

1.2 x 10

8

/rpm : hour

Over 100 

(Base on 500 V d.c mega between terminal and case)

800 V a.c (Between terminal and case at 60Hz for 1 minute)

10~55Hz (Cycle for 1 minute), Double amplitude width: 1.5mm, Each X Y Z direction for 2 hours

40 : 50 G  Max.,  50 : 75 G  Max. 

-10 ~ 60  (Without condensation), Storage Temperatur : -25 ~ 85 

35 ~ 85 % R.H.

Protection IP 50 (IEC Standard)

5 P,   5.0 mm, Length : 1.5 m, Shield cable
(Line Driver Type : 8P,  5.0  mm, Length  : 1.5 m, Shield cable)

40 : 170 g,   50 : 200 g

8.0 mm Coupling, Bracket ( 40mm Bracket  Separate sales)

Load voltage :  30 V Max.

Load Current :  30 mA Max.

Residual Voltage : 0.4 V Max.

1

Max.

(Cable length 1.5 m / sink=30 mA)

1

Max.

(Cable length 1.5 m /
sink=10 mA)

1

Max.

(Cable length 1.5 m /
sink = 30 mA)

For Low
Load Current: 30 mA
Max.
Residual Voltage: 0.4 V
Max.
For High
Load Current: 10 mA
Max.
Residual Voltage: Above
-2.5V of rated voltage

For Low Load Current: 
20 Max.
Residual Voltage: 0.4 V
Max.
For High
Load Current: 20 mA
Max.
Residual Voltage: 2.5 V
Max.

HE

B

- - - -O-

NPN Open collector output

HE

B

- - - -T-

Totem Pole  Output

HE

B

- - - -L-

Line Driver Output

Mode #

Output type

Output type 

Phase difference 

on Output

Max Response     

Frequency

Power voltage

Current 

Consumption

Connection method

Control output 

Response Time

Starting Torque

Moment of inertia

Permissible Shaft 

Loading

Max. Permissible    

Revolution

Bearing Life

Insulation Resistance

Dielectric strength

Vibration Resistance

Shock Resistance

Operating Ambient

Temperature

Operating Ambient

Humidity 

Protection

Wire Specification

Weight

Accessory 

Electrical Specification

Mechanical Specification

Отзывы: