Before start
Installation
Operation
Screen block diagram
Operating screen
Configuration screen
Specifications
31
Parameter
Initial value
Configuration range
Buzzer Time
0 second
0 ~ 9999 seconds
Delay time
0 second
DI 1 Mode
Normal
Normal, Record
DI 1
0
0 ~ 12 (depending on the specification)
DI 2
0
DI 3
0
DI 4
0
[ Alarm configuration parameter ]
[ DI configuration parameter ]
▶DI configuration
Fig. 49) Di configuration screen
Enter the time of keeping the alarm for the
external contact input (DI).
Enter the time delay after the external contact
input (DI).
Configure the functions of the DI 1 operation.
(General, save) The saving works during the
DI 1 input when configured to the save.
Configure the relay operating under the
external contact input (DI). The DI 1 relay
is deactivated if the operation method is
configured to save.
Fig. 50) Operation depending on the DI configuration
External contact
ON
OFF
ON
OFF
ON
OFF
ON
OFF
DI
DI 1 save
alarm
maintenance time
Delay time
maintenance time
The alarm from the operation
of the DI turns off regardless of
the maintenance time when the
screen is touched.
Reference
Parameter
Initial value
Configuration range
Alarm type
Not use
Not use, upper limit, lower limit, within the range, out of the range, within the
deviation among the channels, out of the deviation among the channels
Configuration
High point : Use range (100 %),
Low point : Use range (0 %)
Use range (0 ~ 100 %)
High point
Within : Use range (0 %),
out of : Use range (100 %)
Low point
Use range (0 %)
Deviation
Use range (0 %)
Target
Own channel
1 ~ 12
HYS
Use range (0 %)
Use range (0 ~ 100 %)
Relay
0
0 ~ 12 (depending on the specification)
Alarm method In recording
Always, In recording