Страница 1: ...Version 1 0 Touch Type Graphic Recorder USER MANUAL www hynux com...
Страница 2: ...protected by the copyrights The software is provided as is without warranty of any kind express or implied including but not limited to the warranties of merchantability fitness for a particular purpo...
Страница 3: ...he keypad 10 1 Screen block diagram 11 1 Start and end of the record 12 2 Printing of list 14 3 Alarm 15 4 Trend screen 16 5 Digital screen 17 6 Bar graph screen 18 1 Check the save log 19 2 Function...
Страница 4: ...dy to read The contents of the manual may be altered without prior notice depending on the improvement or functional changes of the product After purchasing the product please check whether the produc...
Страница 5: ...pany does is not responsible for any damages to the user or the third party due to unexpected faults or the act of God losses or indirect damages The warranty period is 1 year from the date of purchas...
Страница 6: ...the gauges off and do the wiring The product operates under 100 240 V AC 50 60 without additional operation Do not use the power other than the ratings This may cause the electric shock or the fire Do...
Страница 7: ...Dimension Panel cutout Fig 1 How to install the panel The tightening torque to fix the clamp is less than 0 5 N m Excessive torque may distort or damage the product Caution Attachment direction panel...
Страница 8: ...to remove the noise The inductive loads L including the motor solenoid and external relay cause the malfunction Connect the CR filters and diodes with the load in parallel in the AC and the DC circui...
Страница 9: ...ith the same wiring resistor Communication wiring Terminal specification Connect the terminating resisters 100 200 0 25 W at both ends of the communication line Fig 3 Communication wiring 2 line conne...
Страница 10: ...TC Thermocouple 14 15 16 Channel 6 RTD Thermoresistor V DC Votage DC TC Thermocouple 17 18 19 Channel 7 RTD Thermoresistor V DC Votage DC TC Thermocouple 20 21 22 Channel 8 RTD Thermoresistor V DC Vo...
Страница 11: ...nied with the alarm beep when the button is deactivated or the configuration is prohibited 2 Button operation Execution button Immediately execute the function on the button Select button Select one o...
Страница 12: ...isplay the parameter name Display the configured character Register the configured character Delete the last digit of the configured character Delete all the configured values Cancel the configuration...
Страница 13: ...operation DI relay View the saved graph copy the data from the internal memory to the SD card Trend screen digital screen bar graph screen Trend screen digital screen bar graph screen Save stop the gr...
Страница 14: ...m the Trend Digital or Bar Graph screen Use the internal memory or the SD card for record Operating screen 1 Start and end of the record Start or end recording on the SD card Start or end the recordin...
Страница 15: ...to use and record with the SD card if the recognition fails Fig 12 Check the record on the SD card Fig 13 Check the stop on the SD card Display recording 50 of the SD card is used The record is automa...
Страница 16: ...d It is not possible to print the list when the record stops It is possible to print the list during the record Press to show the list already recorded The selected list is printed on the screen Cance...
Страница 17: ...ns 3 Alarm It is possible to check the alarm on the Trend Digital or Bar graph screen The alarm is configured in the Alarm and DI It is the status without the alarm It is the status with the alarm Fig...
Страница 18: ...en Go to the digital screen The icon blinks when the reserved operation is configured Click to show or hide the grid Display the measured value with the figure Click to hide or show the graphs for eac...
Страница 19: ...on the screen name Input connection error Display AD error Display Correction error Display Calculation error Display User BURN OUT error Display BURN OUT error Display RJC error Alternatively display...
Страница 20: ...ls Fig 24 Bar graph screen Fig 25 Bar movement screen Display the channel number of each bar graph The user may not change the channel number Display the alarm status and the number of each channel Di...
Страница 21: ...Display the data location indicated by the benchmark line 8 It is the benchmark line for the channel display 9 Go to the first part of the data 10 Move to the previous page 11 Move to the previous pix...
Страница 22: ...ta Magnify the size axis The magnification ratios are 1 2 4 8 times Reduce the size axis It is impossible to reduce to less than 1 Fig 28 View the history display File selection window Select the file...
Страница 23: ...buzzer sound Prevent using the buttons except the trend digital bar graph and view history screens Except moving the screen Enter the user password to change the touch lock parameter The user password...
Страница 24: ...nitial operating screen Trend screen Trend screen See text message Bar graph LIST parameter Graph parameter LIST Graph Fig 32 LIST screen Fig 33 Graph screen Enter the message frequently used on the t...
Страница 25: ...me when the record starts It is impossible to reserve the time if the starting is ahead of the current time It is impossible to change the reserved time during the reservation Reserve the time when th...
Страница 26: ...be changed during recording Configure the VDC input value if the sensor is VDC It may not be changed during recording Configure the decimal point location if the sensor is VDC It may not be changed d...
Страница 27: ...750 0 Wre 5 26 0 0 2300 0 1 0 4200 0 PL II 0 0 1390 0 1 0 2500 0 Range for the sensor types RTD TC Sensor type DCV input range Use range Decimal point range VDC 10 00 20 00 Decimal point 0 10000 2000...
Страница 28: ...red to one channel and apply the parameter to another channel The copy affects the following current channel but does not affect the previous channel Here the channel name is not copied In addition it...
Страница 29: ...ers Calculation function Formula Caution Function Description x Caution 1 4 fundamental arithmetic calculations Involution Caution 2 Remaining calculations Move one space to the left Move one space to...
Страница 30: ...nnel 2 and channel 3 as the dry bulb temperature and the wet bulb temperature respectively Formula Caution Function Description MIN Minimum value MIN CH1 CH4 Minimum value of the CH1 and the CH4 MIN C...
Страница 31: ...rm and DI Alarm configuration Fig 44 Alarm configuration screen Fig 45 Alarm selection screen Fig 46 Select the alarm 1 Upper limit lower limit Configure the alarm type Enter the alarm configuration v...
Страница 32: ...s Warning within the deviation among the channels Warning out of the deviation among the channels HYS POINT HYS POINT HYS HYS L POINT H POINT HYS HYS L POINT H POINT HYS HYS CH HYS CH HYS HYS POINT HY...
Страница 33: ...ternal contact input DI The DI 1 relay is deactivated if the operation method is configured to save Fig 50 Operation depending on the DI configuration External contact ON OFF ON OFF ON OFF ON OFF DI D...
Страница 34: ...he communication program MEMORY RECORD START COMM Start saving to the internal memory with the communication program MEMORY RECORD STOP COMM Stop saving to the internal memory with the communication p...
Страница 35: ...ct input 3 DI 3 contact ON DI3 OFF External contact input 3 DI 3 contact OFF DI4 ON External contact input 4 DI 4 contact ON DI4 OFF External contact input 4 DI 4 contact OFF CHnn SENSOR BURNOUT CHnn...
Страница 36: ...m configuration alarm activated Not configure the relay Configure the relay no relay activated Configure the relay relay activated No DI With DI It shows the alarm status It shows the relay status It...
Страница 37: ...display the product information for the booting Display the product version information Parameter Initial value Configuration range Language English Korean English Chinese simplified traditional Logo...
Страница 38: ...ter the response time Select the stop bit Memory Fig 57 Memory screen Display the used total amount of the internal memory Upload the parameters from the SD card Not work during recording Download the...
Страница 39: ...le name Configure the password to enter the F W window The user may not exit the screen if the user enters the screen Please reboot the system Please configure the password because the firmware upgrad...
Страница 40: ...0 3300 0 15 of F S 1digit 1 S 0 0 1700 0 0 3100 0 15 of F S 1digit 4 L 200 0 900 0 300 1300 0 15 of F S 1digit 2 N 200 0 1300 0 300 2400 0 15 of F S 1digit 3 U 200 0 400 0 300 750 0 15 of F S 1digit...
Страница 41: ...e configuration Input type 2 thermoresistors Pt 100 KPt 100 12 thermocouples K J E T R B S L N U Wre 5 26 PL II 4 VDC 10 20 mV 0 100 mV 1 5V 0 30 V The current input 4 20 DC is available when you use...
Страница 42: ...annel Burn out DI contact input ALARM relay output status The sensor input terminal is insulated among the input channels It is insulated with the relay output terminal the contact input terminal and...
Страница 43: ...reen Configuration screen Specifications 41 Storage environment Impact from the ambient temperature Ambient temperature 20 70 C Temperature change Less than 20 C h Ambient humidity 5 95 RH no condensa...
Страница 44: ...MA0506E131231 HANYOUNG NUX CO LTD 28 Gilpa ro 71 beon gil Nam gu Incheon Korea Tel 82 32 876 4697 Fax 82 32 876 4696 E mail overseas hynux com www hynux com...