Setting lists

Setting information

Divice

change

                    1

st 

level setting type

                                 2

nd 

level setting type

            1

st

 level setting counter

             2

nd

 level setting counter

Input

mode

             CP1, CP2 Individual input UP mode action
             CP1, CP2 Individual input DOWN mode action
Refer to the input action (counter)

Output mode

Refer to the output action (counter)

Output time

(0 : Self holding output, 0.01 - 99.99 : Delay output time)

(0.01 - 99.99 : One shot output time)

Output time

It is not displayed in the 1

st

 level output product

BATCH output

Set the batch output port

          Relay           Transister

Computation speed

Set    or      when using contact

Pre-scale

Default value

Pre-scale

decimal point

setting

Able to set up to 5 decimal points 

and able to shift up to 4 digits

Display unit

decimal point setting

Applied when set decimal point on the display 

unit and able to set up to 3 decimal point 

RESET TIME

Minimum signal range of external RESET signal input

Power

backup memory

            Save the computed value when power is OFF                
            Initialize the computed value when power is OFF

Input logic

check

Varies depending on the handling of internal seitch 

Key lock

Key Lock

             Key lock cancellation
             all keys prohibited (     excluded )
             Using    ,    ,    ,    keys prohibired      
             Using font part      prohibited

Pressing       key will return to operation mode without saving.  Return to operation mode if there is 

no key input more than 60 seconds.  With function setup mode, it ignores external signal input and 

maintains output in OFF state









During the first 100 

 after power input and first 200 

 after power 

opening, it is consider as ascend and descend time of internal power 

and external output power.  Therefore, it does not operate during 

unstable period in order to prevent from malfunction which is caused by 

unstable output operation of external sensor

※ Supply signal only after 100 

 following the power input.  

※ Supply power only after 200 

 following the power shutdown.  

※ Minimum Signal Time refers to ‘ON’ Time.  

Maximum coefficient speed is maximum response speed when entering in the 

duty ratio (ON. OFF ratio) of coefficient input signal as one to one ratio (1:1)  

 As for the input signal below the maximum coefficient speed, if either ON or 

    OFF time is unilaterally less than the standard value of minimum signal width 

      then it may not be counted  

 Minimum Input Time  

•  TOTAL product does not display setting lists such as output mode, OUT2 

output time, OUT1 output time, BATCH output and etc

• 1

st

 setting product does not display OUT1 output time

• Selecting              for BATCH output setting, it limits the setting function and display function.

NONE

▒ GE3

 Counter function setting mode

▒ GE6

  Coefficient display (RED FND)

     Display coefficient value (counter), time process value (timer), batch coefficient  

    value and setup list.

 Setup display (GREEN FND)

     Display setup value (counter), setup time (timer), batch setup value, instant 

output setup (batch setup is 0 in Timer) and setup contents

 SET1, SET2 (SET), BAT  

    Indicates the status of coefficient section and setup section 

    (BAT lamp corresponds to batch status.)  

 TIM (Timer)

     This flashes when the timer progresses and remains lighted when the device 

stops from inhibit input or reset.

    (It is indicated in Change Mode of the device during TIM/TTWIN setup.)

 CNT (Counter)

    This is indicated during 1CNT/2CNT setup in Change Mode of the device.

 OUT1, OUT2(OUT), BAT.O (Output Action Indication) 

    • BAT.O lights up when the batch setup value is set. (OUT1 Output)  

    • BAT.O lights up and outputs when the device operates with the instant output

    • where the batch setup value is 0 (timer).  

    • CP1, CP2, RST : Verification of Input Status. (Exclusively for TOTAL)  

 LOCK:Key Lock (KEY LOCK) Action IndicationThis lights up during Lock Setup.  

⑧    

: This key is for function setup Mode Entry and Mode change. It can also be 

            used for ending after saving when changing the setup value

⑨    

: Setup value change Entry and Location shift

⑩    

: UP Key   

⑪    

: RESET KEY   

When SET, BAT lamp light, RESET key will not operate. 

⑫    

: Batch and operation mode 1 stage and 2 stage conversion key. When BAT 

          lamp light, it is batch mode and keep operate.  

     +     : Push both of keys together, It operate same as      key. 

⑭    

: DOWN Key

※ TOTAL Model does not have Setup Indication Section, SET1, SET2 and BAT 

    Lamp. OUT1, OUT2, BAT.O change their use as CP1, CP2, RST Input Status 

   Check Lamp. 1 Stage Setup Model does not have SET1 and OUT1 Lamp, and 

    SET2 is displayed as SET and OUT2 is displayed as OUT.  

▒ GE4

▒ GE7

Coefficient Speed Selection  Minimum Input Signal 

1 cps

250 

30 cps

11 

1 K cps

0.3 

10 K cps

0.05 

Pressing the"MD" key in the operation mode for 2sec will set the funcion setting mode (               : Default set value)

Power supply

Counter mode setting method

Maximum coefficient speed

Part name and functions

Содержание GE Series

Страница 1: ...V a c 50 60 D 24 60 V d c a c 50 60 If you want to input and output type please contact HANYOUNG sales office Digital counter timer GE series Thank you for purchasing HANYOUNG product Please check whe...

Страница 2: ...ignal width then it may not be counted Minimum Input Time TOTAL product does not display setting lists such as output mode OUT2 output time OUT1 output time BATCH output and etc 1st setting product do...

Страница 3: ...on Coefficient value increases and OUT2 yields One Shot Output The device is reset after the One Shot Output Repetitive Action Coefficient value is maintained and OUT2 yields one shot output OUT1 and...

Страница 4: ...n Timer Default value Decimal system Sexagesimal system TIM TIMER setting TTIM TWN TIMER setting 0 01 s 999999 h UP DOWN selectable Not display in the product display only and some of operation mode i...

Страница 5: ...n the initial setup value When setup time is exceeded it maintains the displaying value and when sets the it yields the ON shot output Runs when START CP2 is ON within the initial setup value When set...

Страница 6: ...tains the indication of initial value when Power is ON Runs when becomes START CP2 ON OFF Repetitious Action of control output after reaching the Set Time Initializes and stops when Reset is ON ONE SH...

Страница 7: ...will exit without changing 3 Pressing key will return to operation mode Left side BAT lamp off Properly operates within BATCH display mode Possible to setup BAT only with BAT setting 48 0 48 0 96 0 4...

Страница 8: ...relay output with transistor Connection of NPN input GE6 T6 Total model does not have relay output with transistor Connection of NPN input GE3 T6 Total model does not have relay output with transisto...

Отзывы: