Setting lists
Setting information
Divice
change
1
st
level setting type
2
nd
level setting type
1
st
level setting counter
2
nd
level setting counter
Input
mode
CP1, CP2 Individual input UP mode action
CP1, CP2 Individual input DOWN mode action
Refer to the input action (counter)
Output mode
Refer to the output action (counter)
Output time
(0 : Self holding output, 0.01 - 99.99 : Delay output time)
(0.01 - 99.99 : One shot output time)
Output time
It is not displayed in the 1
st
level output product
BATCH output
Set the batch output port
Relay Transister
Computation speed
Set or when using contact
Pre-scale
Default value
Pre-scale
decimal point
setting
Able to set up to 5 decimal points
and able to shift up to 4 digits
Display unit
decimal point setting
Applied when set decimal point on the display
unit and able to set up to 3 decimal point
RESET TIME
Minimum signal range of external RESET signal input
Power
backup memory
Save the computed value when power is OFF
Initialize the computed value when power is OFF
Input logic
check
Varies depending on the handling of internal seitch
Key lock
Key Lock
Key lock cancellation
all keys prohibited ( excluded )
Using , , , keys prohibired
Using font part prohibited
Pressing key will return to operation mode without saving. Return to operation mode if there is
no key input more than 60 seconds. With function setup mode, it ignores external signal input and
maintains output in OFF state
①
②
③
④
⑤
⑥
⑦
⑧
⑨
⑩
⑫
⑪
①
②
③
④
⑤
⑥
⑦
⑧
⑨
⑩
⑫
⑪
①
②
③
④
⑤
⑥
⑦
⑧
⑨
⑩
⑪
⑬
①
②
③
④
⑤
⑥
⑦
⑧
⑨
⑫
⑩
⑪
⑭
During the first 100
㎳
after power input and first 200
㎳
after power
opening, it is consider as ascend and descend time of internal power
and external output power. Therefore, it does not operate during
unstable period in order to prevent from malfunction which is caused by
unstable output operation of external sensor
※ Supply signal only after 100
㎳
following the power input.
※ Supply power only after 200
㎳
following the power shutdown.
※ Minimum Signal Time refers to ‘ON’ Time.
Maximum coefficient speed is maximum response speed when entering in the
duty ratio (ON. OFF ratio) of coefficient input signal as one to one ratio (1:1)
①
As for the input signal below the maximum coefficient speed, if either ON or
OFF time is unilaterally less than the standard value of minimum signal width
then it may not be counted
②
Minimum Input Time
• TOTAL product does not display setting lists such as output mode, OUT2
output time, OUT1 output time, BATCH output and etc
• 1
st
setting product does not display OUT1 output time
• Selecting for BATCH output setting, it limits the setting function and display function.
NONE
▒ GE3
▒
Counter function setting mode
▒ GE6
①
Coefficient display (RED FND)
Display coefficient value (counter), time process value (timer), batch coefficient
value and setup list.
②
Setup display (GREEN FND)
Display setup value (counter), setup time (timer), batch setup value, instant
output setup (batch setup is 0 in Timer) and setup contents
③
SET1, SET2 (SET), BAT
Indicates the status of coefficient section and setup section
(BAT lamp corresponds to batch status.)
④
TIM (Timer)
This flashes when the timer progresses and remains lighted when the device
stops from inhibit input or reset.
(It is indicated in Change Mode of the device during TIM/TTWIN setup.)
⑤
CNT (Counter)
This is indicated during 1CNT/2CNT setup in Change Mode of the device.
⑥
OUT1, OUT2(OUT), BAT.O (Output Action Indication)
• BAT.O lights up when the batch setup value is set. (OUT1 Output)
• BAT.O lights up and outputs when the device operates with the instant output
• where the batch setup value is 0 (timer).
• CP1, CP2, RST : Verification of Input Status. (Exclusively for TOTAL)
⑦
LOCK:Key Lock (KEY LOCK) Action IndicationThis lights up during Lock Setup.
⑧
: This key is for function setup Mode Entry and Mode change. It can also be
used for ending after saving when changing the setup value
⑨
: Setup value change Entry and Location shift
⑩
: UP Key
⑪
: RESET KEY
③
When SET, BAT lamp light, RESET key will not operate.
⑫
: Batch and operation mode 1 stage and 2 stage conversion key. When BAT
lamp light, it is batch mode and keep operate.
⑬
+ : Push both of keys together, It operate same as key.
⑭
: DOWN Key
※ TOTAL Model does not have Setup Indication Section, SET1, SET2 and BAT
Lamp. OUT1, OUT2, BAT.O change their use as CP1, CP2, RST Input Status
Check Lamp. 1 Stage Setup Model does not have SET1 and OUT1 Lamp, and
SET2 is displayed as SET and OUT2 is displayed as OUT.
▒ GE4
▒ GE7
Coefficient Speed Selection Minimum Input Signal
1 cps
250
㎳
30 cps
11
㎳
1 K cps
0.3
㎳
10 K cps
0.05
㎳
Pressing the"MD" key in the operation mode for 2sec will set the funcion setting mode ( : Default set value)
Power supply
Counter mode setting method
Maximum coefficient speed
Part name and functions