SPECIFICATIONS
Ethernet
Data Interface
10/100BaseT(X) Ethernet
IEEE 802.3 Compliant
Full Duplex or Half Duplex Electrical Ports
Standards
IEEE: 802.3af PoE, 802.3at PoE+
RFC: 768 UDP, 2068 HTTP, 793 TCP, 791 IP, 1783
TFTP, 894 IP over Ethernet, 2544 TCP/IP Packet
Transmission
Transmission Distances
1
See chart below
Connectors
Ethernet
2 × RJ-45
Power
Pass-Through Mode
Operates on PoE Power
Power Consumption
< 1 W
Protection
High Impedance PoE Pass-Through with Start-up
Voltage Detection and Current Limiting
Mechanical
Indicating LEDs
Ethernet Link and Activity
Circuit Board
Meets IPC Standard
TER-F01[/PD] Size
3.3 × 1.25 × 1.25 in (8.4 × 3.2 × 3.2 cm)
Shipping Weight
<1 lbs./0.5 kg
Environmental
MTBF
>100,000 hours
Operating Temp
– 40˚ C to +75˚ C
Storage Temp
– 40˚ C to +80˚ C
Relative Humidity
0% to 95% (non-condensing)²
AGENCY COMPLIANCE
MAXIMUM TRANSMISSION DISTANCES
1
Maximum Range & Repeaters for PoE Power (Watts)
PoE Source
No PoE³
5 W
10 W
15W
20 W
25 W
15 W PoE Switch
2,625 ft
800 m
(Using 7 TER-F01)
1,476 ft
450 m
(Using 4 TER-F01)
984 ft
300 m
(Using 2 TER-F01)
328 ft
4
100 m
4
(No TER-F01)
N/A
4
N/A
4
30 W PoE+ Switch
2,625 ft
800 m
(Using 7 TER-F01)
1,969 ft
600 m
(Using 5 TER-F01)
1,316 ft
400 m
(Using 3 TER-F01)
984 ft
300 m
(Using 2 TER-F01)
656 ft
200 m
(Using 1 TER-F01)
328 ft
4
100 m
4
(No TER-F01)
35 W PoE+ Injector
3,773 ft
1,150 m
(Using 11 TER-F01)
2,625 ft
800 m
(Using 7 TER-F01)
1,804 ft
550 m
(Using 5 TER-F01)
1,316 ft
400 m
(Using 3 TER-F01)
984 ft
300 m
(Using 2 TER-F01)
656 ft
200 m
(Using 1 TER-F01)
[1] Distance figures are based on 48V PSE PoE power source for PoE switches, 50V PSE PoE power source for PoE+ switches and 56V PSE PoE
power source for the injector as detailed in the table. Distance figures are obtained using in-house testing mirroring installations. Factors
such as cable quality, the number of connectors and splices in the cable run, the use of PoE, and environmental conditions encountered
within the installation might affect the actual transmission distance and should be taken into consideration.
[3] Non-PoE applications; using a TER-F01PD model at the end of the chain
[4] Extension is not
needed/possible
at this PoE power level with this particular PoE power source
at the distance listed
INS_TER-F01[PD]
08/12/19
PAGE
3
INSTALLATION AND OPERATION MANUAL
TER-F01 SERIES